Since commit 32fd6901 (MIPS: Alchemy: get rid of common/reset.c)
Alchemy-based boards use their own reset function. For MTX-1 and XXS1500,
the reset function pokes at the BCSR.SYSTEM_RESET register, but this does
not work. According to Bruno Randolf, this was not tested when written.
Previously, the generic au1000_restart() routine called the board specific
reset function, which for MTX-1 and XXS1500 did not work, but finally made
a jump to the reset vector, which really triggers a system restart. Fix
reboot for both targets by jumping to the reset vector.
Signed-off-by: Florian Fainelli <florian@openwrt.org>
To: linux-mips@linux-mips.org
Patchwork: https://patchwork.linux-mips.org/patch/2093/
Acked-by: Bruno Randolf <br1@einfach.org>
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>