Hauke Mehrtens 978e55d2d8 bcma: prevent irq handler from firing when registered
With this patch we prevent the irq from being fired when it is
registered. The Hardware fires an IRQ when input signal XOR polarity
AND gpio mask is 1. Now we are setting polarity to a vlaue so that is
is 0 when we register it.

In addition we also set the irq mask register to 0 when the irq handler
is initialized, so all gpio irqs are masked and there will be no
unexpected irq.

Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Tested-by: Rafał Miłecki <zajec5@gmail.com>
Signed-off-by: John Crispin <blogic@openwrt.org>
Patchwork: http://patchwork.linux-mips.org/patch/6304/
2014-01-24 22:39:52 +01:00
..
2013-06-27 13:42:16 -04:00
2013-04-05 13:04:07 +01:00
2013-10-10 13:46:00 -04:00
2012-08-10 15:26:52 -04:00
2014-01-23 13:02:37 +01:00
2012-11-21 21:55:52 +01:00
2013-06-27 13:42:16 -04:00

Broadcom introduced new bus as replacement for older SSB. It is based on AMBA,
however from programming point of view there is nothing AMBA specific we use.

Standard AMBA drivers are platform specific, have hardcoded addresses and use
AMBA standard fields like CID and PID.

In case of Broadcom's cards every device consists of:
1) Broadcom specific AMBA device. It is put on AMBA bus, but can not be treated
   as standard AMBA device. Reading it's CID or PID can cause machine lockup.
2) AMBA standard devices called ports or wrappers. They have CIDs (AMBA_CID)
   and PIDs (0x103BB369), but we do not use that info for anything. One of that
   devices is used for managing Broadcom specific core.

Addresses of AMBA devices are not hardcoded in driver and have to be read from
EPROM.

In this situation we decided to introduce separated bus. It can contain up to
16 devices identified by Broadcom specific fields: manufacturer, id, revision
and class.