Krzysztof Mazur 9eba25268e br2684: allow assign only on a connected socket
The br2684 does not check if used vcc is in connected state,
causing potential Oops in pppoatm_send() when vcc->send() is called
on not fully connected socket.

Now br2684 can be assigned only on connected sockets; otherwise
-EINVAL error is returned.

Signed-off-by: Krzysztof Mazur <krzysiek@podlesie.net>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
2012-12-02 00:05:19 +00:00
..
2012-10-14 22:41:27 -07:00
2012-09-26 21:10:25 -04:00