The standard snd_soc_info_volsw() detects if a control is a volume control and needs to be reported as an integer even if it only has two values by looking for the string " Volume" in the control name. This results in false positives if the control has a name like "HP Volume Ramp Switch" since any " Volume" is matched, not just a trailing one. Fix this by making sure that we only match at the end of the control name. Signed-off-by: Mark Brown <broonie@kernel.org> Link: https://lore.kernel.org/r/20220604105407.4055294-1-broonie@kernel.org Signed-off-by: Mark Brown <broonie@kernel.org>
…
Linux kernel ============ There are several guides for kernel developers and users. These guides can be rendered in a number of formats, like HTML and PDF. Please read Documentation/admin-guide/README.rst first. In order to build the documentation, use ``make htmldocs`` or ``make pdfdocs``. The formatted documentation can also be read online at: https://www.kernel.org/doc/html/latest/ There are various text files in the Documentation/ subdirectory, several of them using the Restructured Text markup notation. Please read the Documentation/process/changes.rst file, as it contains the requirements for building and running the kernel, and information about the problems which may result by upgrading your kernel.