Nicholas Piggin b2b46304e9 powerpc: re-initialise lazy FPU/VEC counters on every fault
When a FP/VEC/VSX unavailable fault loads registers and enables the
facility in the MSR, re-set the lazy restore counters to 1 rather
than incrementing them so every fault gets the same number of
restores before the next fault.

This probably shouldn't be a practical change because if a lazy counter
was non-zero then it should have been restored and would not cause a
fault when userspace tries to access it. However the code and comment
implies otherwise so that's misleading and unnecessary.

Signed-off-by: Nicholas Piggin <npiggin@gmail.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Link: https://lore.kernel.org/r/20200623234139.2262227-3-npiggin@gmail.com
2020-07-16 13:00:24 +10:00
..