Lothar Waßmann c080846749 Input: edt-ft5x06 - adjust delays to conform datasheet
The FT5x06 datasheet specifies a minimum reset width of 5ms and a
delay between deassertion of reset and start of reporting of 300ms.
Adjust the delays to conform to the datasheet.

With the original delays I sometimes experienced communication
timeouts when initializing the controller.

Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de>
Acked-by: Fugang Duan <B38611@freescale.com>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
2014-03-28 09:33:05 -07:00
..
2014-01-27 22:34:49 -08:00
2012-08-21 22:29:49 -07:00
2012-08-21 22:29:49 -07:00
2012-08-21 22:29:49 -07:00
2014-01-23 08:10:44 -08:00
2012-08-21 22:29:49 -07:00