Vladimir Oltean c0d7eccbc7 net: mscc: ocelot: ANA_AUTOAGE_AGE_PERIOD holds a value in seconds, not ms
One may notice that automatically-learnt entries 'never' expire, even
though the bridge configures the address age period at 300 seconds.

Actually the value written to hardware corresponds to a time interval
1000 times higher than intended, i.e. 83 hours.

Fixes: a556c76adc05 ("net: mscc: Add initial Ocelot switch support")
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Faineli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>