Alan Brady c53d11f669 i40e: fix client notify of VF reset
Currently there is a bug in which the PF driver fails to inform clients
of a VF reset which then causes clients to leak resources.  The bug
exists because we were incorrectly checking the I40E_VF_STATE_PRE_ENABLE
bit.

When a VF is first init we go through a reset to initialize variables
and allocate resources but we don't want to inform clients of this first
reset since the client isn't fully enabled yet so we set a state bit
signifying we're in a "pre-enabled" client state.  During the first
reset we should be clearing the bit, allowing all following resets to
notify the client of the reset when the bit is not set.  This patch
fixes the issue by negating the 'test_and_clear_bit' check to accurately
reflect the behavior we want.

Signed-off-by: Alan Brady <alan.brady@intel.com>
Tested-by: Andrew Bowers <andrewx.bowers@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
2017-10-02 12:46:36 -07:00
2017-10-02 11:06:07 -07:00
2017-09-23 05:33:29 -10:00
2017-09-12 13:21:00 -07:00
2017-09-16 15:47:51 -07:00

Linux kernel
============

This file was moved to Documentation/admin-guide/README.rst

Please notice that there are several guides for kernel developers and users.
These guides can be rendered in a number of formats, like HTML and PDF.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.
See Documentation/00-INDEX for a list of what is contained in each file.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
Description
No description provided
Readme 5.7 GiB
Languages
C 97.6%
Assembly 1%
Shell 0.5%
Python 0.3%
Makefile 0.3%