Johannes Weiner cb8799eedd rtc-x1205: reset clock to sane state after power failure
When detecting power failure, the probe function would reset the clock
time to defined state.

However, the clock's _date_ might still be bogus and a subsequent probe
fails when sanity-checking these values.

Change the power-failure fixup code to do a full setting of rtc_time,
including a valid date.

Signed-off-by: Johannes Weiner <jw@emlix.com>
Cc: Alessandro Zummo <a.zummo@towertech.it>
Cc: Paul Gortmaker <p_gortmaker@yahoo.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>