When parsing via script, it is important to know if the script should consider a description as a literal block that should be displayed as-is, or if the description can be considered as a normal text. Change descriptions to ensure that the preceding line of a table ends with a colon. That makes easy to identify the need of a literal block. Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com> Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
66 lines
1.5 KiB
Plaintext
66 lines
1.5 KiB
Plaintext
What: /sys/class/leds/<led>/als_channel
|
|
Date: May 2012
|
|
KernelVersion: 3.5
|
|
Contact: Johan Hovold <jhovold@gmail.com>
|
|
Description:
|
|
Set the ALS output channel to use as input in
|
|
ALS-current-control mode (1, 2), where:
|
|
|
|
1 - out_current1
|
|
2 - out_current2
|
|
|
|
What: /sys/class/leds/<led>/als_en
|
|
Date: May 2012
|
|
KernelVersion: 3.5
|
|
Contact: Johan Hovold <jhovold@gmail.com>
|
|
Description:
|
|
Enable ALS-current-control mode (0, 1).
|
|
|
|
What: /sys/class/leds/<led>/falltime
|
|
What: /sys/class/leds/<led>/risetime
|
|
Date: April 2012
|
|
KernelVersion: 3.5
|
|
Contact: Johan Hovold <jhovold@gmail.com>
|
|
Description:
|
|
Set the pattern generator fall and rise times (0..7), where:
|
|
|
|
0 - 2048 us
|
|
1 - 262 ms
|
|
2 - 524 ms
|
|
3 - 1.049 s
|
|
4 - 2.097 s
|
|
5 - 4.194 s
|
|
6 - 8.389 s
|
|
7 - 16.78 s
|
|
|
|
What: /sys/class/leds/<led>/id
|
|
Date: April 2012
|
|
KernelVersion: 3.5
|
|
Contact: Johan Hovold <jhovold@gmail.com>
|
|
Description:
|
|
Get the id of this led (0..3).
|
|
|
|
What: /sys/class/leds/<led>/linear
|
|
Date: April 2012
|
|
KernelVersion: 3.5
|
|
Contact: Johan Hovold <jhovold@gmail.com>
|
|
Description:
|
|
Set the brightness-mapping mode (0, 1), where:
|
|
|
|
0 - exponential mode
|
|
1 - linear mode
|
|
|
|
What: /sys/class/leds/<led>/pwm
|
|
Date: April 2012
|
|
KernelVersion: 3.5
|
|
Contact: Johan Hovold <jhovold@gmail.com>
|
|
Description:
|
|
Set the PWM-input control mask (5 bits), where:
|
|
|
|
bit 5 - PWM-input enabled in Zone 4
|
|
bit 4 - PWM-input enabled in Zone 3
|
|
bit 3 - PWM-input enabled in Zone 2
|
|
bit 2 - PWM-input enabled in Zone 1
|
|
bit 1 - PWM-input enabled in Zone 0
|
|
bit 0 - PWM-input enabled
|