Fabrice Gasnier b14d72ac73 counter: stm32-timer-cnt: fix ceiling miss-alignment with reload register
Ceiling value may be miss-aligned with what's actually configured into the
ARR register. This is seen after probe as currently the ARR value is zero,
whereas ceiling value is set to the maximum. So:
- reading ceiling reports zero
- in case the counter gets enabled without any prior configuration,
  it won't count.
- in case the function gets set by the user 1st, (priv->ceiling) is used.

Fix it by getting rid of the cached "priv->ceiling" variable. Rather use
the ARR register value directly by using regmap read or write when needed.
There should be no drawback on performance as priv->ceiling isn't used in
performance critical path.
There's also no point in writing ARR while setting function (sms), so
it can be safely removed.

Fixes: ad29937e206f ("counter: Add STM32 Timer quadrature encoder")
Suggested-by: William Breathitt Gray <vilhelm.gray@gmail.com>
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@foss.st.com>
Acked-by: William Breathitt Gray <vilhelm.gray@gmail.com>
Cc: <Stable@vger.kernel.org>
Link: https://lore.kernel.org/r/1614793789-10346-1-git-send-email-fabrice.gasnier@foss.st.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2021-03-06 16:48:09 +00:00
..
2020-07-20 09:37:31 +02:00
2021-01-14 20:56:56 +00:00