Stefan Brüns e5c2ce6bac iio: adc: Fix polling of INA219 conversion ready flag
While the INA226 has a conversion ready flag (CVRF) in the R/W Mask/Enable
register with read-to-clear semantics, the corresponding bit of the INA219
(CNVR) is part of the bus voltage register. The flag is cleared by reading
the power register.

Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2017-07-01 10:16:47 +01:00
..
2017-06-12 08:20:47 +02:00