[ Upstream commit 4043ecfb5fc4355a090111e14faf7945ff0fdbd5 ] Fix bug in sampling function hx711_cycle() when interrupt occures while PD_SCK is high. If PD_SCK is high for at least 60 us power down mode of the sensor is entered which in turn leads to a wrong measurement. Switch off interrupts during a PD_SCK high period and move query of DOUT to the latest point of time which is at the end of PD_SCK low period. This bug exists in the driver since it's initial addition. The more interrupts on the system the higher is the probability that it happens. Fixes: c3b2fdd0ea7e ("iio: adc: hx711: Add IIO driver for AVIA HX711") Signed-off-by: Andreas Klinger <ak@it-klinger.de> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
…
Linux kernel ============ This file was moved to Documentation/admin-guide/README.rst Please notice that there are several guides for kernel developers and users. These guides can be rendered in a number of formats, like HTML and PDF. In order to build the documentation, use ``make htmldocs`` or ``make pdfdocs``. There are various text files in the Documentation/ subdirectory, several of them using the Restructured Text markup notation. See Documentation/00-INDEX for a list of what is contained in each file. Please read the Documentation/process/changes.rst file, as it contains the requirements for building and running the kernel, and information about the problems which may result by upgrading your kernel.