Mathias Nyman f59f93cd1d usb: hub: avoid warm port reset during USB3 disconnect
During disconnect USB-3 ports often go via SS.Inactive link error state
before the missing terminations are noticed, and link finally goes to
RxDetect state

Avoid immediately warm-resetting ports in SS.Inactive state.
Let ports settle for a while and re-read the link status a few times 20ms
apart to see if the ports transitions out of SS.Inactive.

According to USB 3.x spec 7.5.2, a port in SS.Inactive should
automatically check for missing far-end receiver termination every
12 ms (SSInactiveQuietTimeout)

The futile multiple warm reset retries of a disconnected device takes
a lot of time, also the resetting of a removed devices has caused cases
where the reset bit got stuck for a long time on xHCI roothub.
This lead to issues in detecting new devices connected to the same port
shortly after.

Tested-by: Mark Pearson <markpearson@lenovo.com>
Signed-off-by: Mathias Nyman <mathias.nyman@linux.intel.com>
Link: https://lore.kernel.org/r/20211210111653.1378381-1-mathias.nyman@linux.intel.com
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2021-12-15 23:48:37 +01:00
..
2019-06-26 10:28:09 +08:00
2020-06-18 10:13:16 +02:00
2021-04-09 16:00:00 +02:00