commit 13a779de4175df602366d129e41782ad7168cef0 upstream. The idx_to_offset() function returns type int (32-bit signed), but MSR_PKG_ENERGY_STAT is u32 and would be interpreted as a negative number. The end result is that it hits the if (offset < 0) check in update_msr_sum() which prevents the timer callback from updating the stat in the background when long durations are used. The similar issue exists in offset_to_idx() and update_msr_sum(). Fix this issue by converting the 'int' to 'off_t' accordingly. Fixes: 9972d5d84d76 ("tools/power turbostat: Enable accumulate RAPL display") Signed-off-by: Calvin Walton <calvin.walton@kepstin.ca> Signed-off-by: Len Brown <len.brown@intel.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>