Matti Vaittinen 60d6d27040 iio: kx022a: Fix acceleration value scaling
commit 92bfa4ab1b79be95c4f52d13f5386390f0a513c2 upstream.

The IIO ABI mandates acceleration values from accelerometer to be
emitted in m/s^2. The KX022A was emitting values in micro m/s^2.

Fix driver to report the correct scale values.

Signed-off-by: Matti Vaittinen <mazziesaccount@gmail.com>
Reported-by: Jagath Jog J <jagathjog1996@gmail.com>
Fixes: 7c1d1677b322 ("iio: accel: Support Kionix/ROHM KX022A accelerometer")
Tested-by: Jagath Jog J <jagathjog1996@gmail.com>
Link: https://lore.kernel.org/r/ZTEt7NqfDHPOkm8j@dc78bmyyyyyyyyyyyyydt-3.rev.dnainternet.fi
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2024-01-01 12:42:37 +00:00
..
2022-02-21 19:33:06 +00:00
2023-01-08 13:01:02 +00:00