Gabor Juhos 66b6da0cc6 clk: qcom: clk-alpha-pll: set ALPHA_EN bit for Stromer Plus PLLs
[ Upstream commit 5a33a64524e6381c399e5e42571d9363ffc0bed4 ]

The clk_alpha_pll_stromer_plus_set_rate() function does not
sets the ALPHA_EN bit in the USER_CTL register, so setting
rates which requires using alpha mode works only if the bit
gets set already prior calling the function.

Extend the function to set the ALPHA_EN bit in order to allow
using fractional rates regardless whether the bit gets set
previously or not.

Fixes: 84da48921a97 ("clk: qcom: clk-alpha-pll: introduce stromer plus ops")
Signed-off-by: Gabor Juhos <j4g8y7@gmail.com>
Link: https://lore.kernel.org/r/20240508-stromer-plus-alpha-en-v1-1-6639ce01ca5b@gmail.com
Signed-off-by: Bjorn Andersson <andersson@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
2024-07-11 12:49:19 +02:00
..