1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-22 17:35:59 +03:00
lvm2/daemons/lvmdbusd/pv.py

283 lines
8.1 KiB
Python
Raw Normal View History

2016-02-18 02:53:35 +03:00
# Copyright (C) 2015-2016 Red Hat, Inc. All rights reserved.
#
# This copyrighted material is made available to anyone wishing to use,
# modify, copy, or redistribute it subject to the terms and conditions
# of the GNU General Public License v.2.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/>.
from .automatedproperties import AutomatedProperties
from . import utils
from . import cfg
import dbus
from .cfg import PV_INTERFACE
from . import cmdhandler
from .utils import vg_obj_path_generate, n, pv_obj_path_generate, \
lv_object_path_method
from .loader import common
from .request import RequestEntry
from .state import State
from .utils import round_size
# noinspection PyUnusedLocal
def pvs_state_retrieve(selection, cache_refresh=True):
rc = []
if cache_refresh:
cfg.db.refresh()
for p in cfg.db.fetch_pvs(selection):
rc.append(
PvState(
p["pv_name"], p["pv_uuid"], p["pv_name"],
p["pv_fmt"], n(p["pv_size"]), n(p["pv_free"]),
n(p["pv_used"]), n(p["dev_size"]), n(p["pv_mda_size"]),
n(p["pv_mda_free"]), int(p["pv_ba_start"]),
n(p["pv_ba_size"]), n(p["pe_start"]),
int(p["pv_pe_count"]), int(p["pv_pe_alloc_count"]),
p["pv_attr"], p["pv_tags"], p["vg_name"], p["vg_uuid"]))
return rc
def load_pvs(device=None, object_path=None, refresh=False, emit_signal=False,
cache_refresh=True):
return common(
pvs_state_retrieve, (Pv,), device, object_path, refresh,
emit_signal, cache_refresh)
# noinspection PyUnresolvedReferences
class PvState(State):
@property
def lvm_id(self):
return self.lvm_path
def _lv_object_list(self, vg_name):
# Note we are returning "a(oa(tts))"
rc = []
if vg_name:
for lv in sorted(cfg.db.pv_contained_lv(self.lvm_id)):
lv_uuid, lv_name, meta, segs = lv
full_name = "%s/%s" % (vg_name, lv_name)
path_create = lv_object_path_method(lv_name, meta)
lv_path = cfg.om.get_object_path_by_lvm_id(
lv_uuid, full_name, path_create)
rc.append((lv_path, segs))
return dbus.Array(rc, signature="(oa(tts))")
# noinspection PyUnusedLocal,PyPep8Naming
def __init__(self, lvm_path, Uuid, Name,
Fmt, SizeBytes, FreeBytes, UsedBytes, DevSizeBytes,
MdaSizeBytes, MdaFreeBytes, BaStart, BaSizeBytes,
PeStart, PeCount, PeAllocCount, attr, Tags, vg_name,
vg_uuid):
utils.init_class_from_arguments(self)
self.pe_segments = cfg.db.pv_pe_segments(Uuid)
self.lv = self._lv_object_list(vg_name)
if vg_name:
self.vg_path = cfg.om.get_object_path_by_lvm_id(
vg_uuid, vg_name, vg_obj_path_generate)
else:
self.vg_path = '/'
def identifiers(self):
return (self.Uuid, self.lvm_path)
def create_dbus_object(self, path):
if not path:
path = cfg.om.get_object_path_by_lvm_id(self.Uuid, self.Name,
pv_obj_path_generate)
return Pv(path, self)
# noinspection PyMethodMayBeStatic
def creation_signature(self):
return (Pv, pv_obj_path_generate)
# noinspection PyPep8Naming
@utils.dbus_property(PV_INTERFACE, 'Uuid', 's') # PV UUID/pv_uuid
@utils.dbus_property(PV_INTERFACE, 'Name', 's') # PV/pv_name
@utils.dbus_property(PV_INTERFACE, 'Fmt', 's') # Fmt/pv_fmt
@utils.dbus_property(PV_INTERFACE, 'SizeBytes', 't') # PSize/pv_size
@utils.dbus_property(PV_INTERFACE, 'FreeBytes', 't') # PFree/pv_free
@utils.dbus_property(PV_INTERFACE, 'UsedBytes', 't') # Used/pv_used
@utils.dbus_property(PV_INTERFACE, 'DevSizeBytes', 't') # DevSize/dev_size
@utils.dbus_property(PV_INTERFACE, 'MdaSizeBytes', 't') # PMdaSize/pv_mda_size
@utils.dbus_property(PV_INTERFACE, 'MdaFreeBytes', 't') # PMdaFree/pv_mda_free
@utils.dbus_property(PV_INTERFACE, 'BaStart', 't') # BA start/pv_ba_start
@utils.dbus_property(PV_INTERFACE, 'BaSizeBytes', 't') # BA size/pv_ba_size
@utils.dbus_property(PV_INTERFACE, 'PeStart', 't') # 1st PE/pe_start
@utils.dbus_property(PV_INTERFACE, 'PeCount', 't') # PE/pv_pe_count
@utils.dbus_property(PV_INTERFACE, 'PeAllocCount', 't') # PE Allocation count
class Pv(AutomatedProperties):
# For properties that we need custom handlers we need these, otherwise
# we won't get our introspection data
_Tags_meta = ("as", PV_INTERFACE)
_PeSegments_meta = ("a(tt)", PV_INTERFACE)
_Exportable_meta = ("b", PV_INTERFACE)
_Allocatable_meta = ("b", PV_INTERFACE)
_Missing_meta = ("b", PV_INTERFACE)
_Lv_meta = ("a(oa(tts))", PV_INTERFACE)
_Vg_meta = ("o", PV_INTERFACE)
# noinspection PyUnusedLocal,PyPep8Naming
def __init__(self, object_path, state_obj):
super(Pv, self).__init__(object_path, pvs_state_retrieve)
self.set_interface(PV_INTERFACE)
self.state = state_obj
@staticmethod
def _remove(pv_uuid, pv_name, remove_options):
# Remove the PV, if successful then remove from the model
# Make sure we have a dbus object representing it
dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name)
if dbo:
rc, out, err = cmdhandler.pv_remove(pv_name, remove_options)
if rc == 0:
cfg.om.remove_object(dbo, True)
else:
# Need to work on error handling, need consistent
raise dbus.exceptions.DBusException(
PV_INTERFACE,
'Exit code %s, stderr = %s' % (str(rc), err))
else:
raise dbus.exceptions.DBusException(
PV_INTERFACE,
'PV with uuid %s and name %s not present!' %
(pv_uuid, pv_name))
return '/'
@dbus.service.method(
dbus_interface=PV_INTERFACE,
in_signature='ia{sv}',
out_signature='o',
async_callbacks=('cb', 'cbe'))
def Remove(self, tmo, remove_options, cb, cbe):
r = RequestEntry(
tmo, Pv._remove,
(self.Uuid, self.lvm_id, remove_options),
cb, cbe, return_tuple=False)
cfg.worker_q.put(r)
@staticmethod
def _resize(pv_uuid, pv_name, new_size_bytes, resize_options):
# Make sure we have a dbus object representing it
dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name)
if dbo:
rc, out, err = cmdhandler.pv_resize(pv_name, new_size_bytes,
resize_options)
if rc == 0:
dbo.refresh()
else:
raise dbus.exceptions.DBusException(
PV_INTERFACE,
'Exit code %s, stderr = %s' % (str(rc), err))
else:
raise dbus.exceptions.DBusException(
PV_INTERFACE,
'PV with uuid %s and name %s not present!' %
(pv_uuid, pv_name))
return '/'
@dbus.service.method(
dbus_interface=PV_INTERFACE,
in_signature='tia{sv}',
out_signature='o',
async_callbacks=('cb', 'cbe'))
def ReSize(self, new_size_bytes, tmo, resize_options, cb, cbe):
r = RequestEntry(
tmo, Pv._resize,
(self.Uuid, self.lvm_id, round_size(new_size_bytes),
resize_options), cb, cbe, False)
cfg.worker_q.put(r)
@staticmethod
def _allocation_enabled(pv_uuid, pv_name, yes_no, allocation_options):
# Make sure we have a dbus object representing it
dbo = cfg.om.get_object_by_uuid_lvm_id(pv_uuid, pv_name)
if dbo:
rc, out, err = cmdhandler.pv_allocatable(
pv_name, yes_no, allocation_options)
if rc == 0:
cfg.load()
else:
raise dbus.exceptions.DBusException(
PV_INTERFACE, 'Exit code %s, stderr = %s' % (str(rc), err))
else:
raise dbus.exceptions.DBusException(
PV_INTERFACE,
'PV with uuid %s and name %s not present!' %
(pv_uuid, pv_name))
return '/'
@dbus.service.method(
dbus_interface=PV_INTERFACE,
in_signature='bia{sv}',
out_signature='o',
async_callbacks=('cb', 'cbe'))
def AllocationEnabled(self, yes, tmo, allocation_options, cb, cbe):
r = RequestEntry(
tmo, Pv._allocation_enabled,
(self.Uuid, self.lvm_id,
yes, allocation_options),
cb, cbe, False)
cfg.worker_q.put(r)
@property
def Tags(self):
return utils.parse_tags(self.state.Tags)
@property
def PeSegments(self):
if len(self.state.pe_segments):
return self.state.pe_segments
return dbus.Array([], '(tt)')
@property
def Exportable(self):
if self.state.attr[1] == 'x':
return True
return False
@property
def Allocatable(self):
if self.state.attr[0] == 'a':
return True
return False
@property
def Missing(self):
if self.state.attr[2] == 'm':
return True
return False
def object_path(self):
return self._object_path
@property
def lvm_id(self):
return self.state.lvm_id
@property
def identifiers(self):
return self.state.identifiers()
@property
def Lv(self):
return self.state.lv
@property
def Vg(self):
return self.state.vg_path