mirror of
git://sourceware.org/git/lvm2.git
synced 2024-12-21 13:34:40 +03:00
lvmlockd: do not allow mirror LV to be activated shared
This reverts 518a8e8cfb
"lvmlockd: activate mirror LVs in shared mode with cmirrord"
because while activating a mirror LV with cmirrord worked,
changes to the active cmirror did not work.
This commit is contained in:
parent
50800e33d5
commit
c33770c02d
@ -159,7 +159,6 @@ struct cmd_context {
|
||||
unsigned lockd_gl_removed:1;
|
||||
unsigned lockd_vg_default_sh:1;
|
||||
unsigned lockd_vg_enforce_sh:1;
|
||||
unsigned lockd_lv_sh:1;
|
||||
unsigned lockd_lv_sh_for_ex:1;
|
||||
unsigned vg_notify:1;
|
||||
unsigned lv_notify:1;
|
||||
|
@ -2160,15 +2160,6 @@ int lockd_lv_name(struct cmd_context *cmd, struct volume_group *vg,
|
||||
return 0;
|
||||
}
|
||||
|
||||
/*
|
||||
* This is a hack for mirror LVs which need to know at a very low level
|
||||
* which lock mode the LV is being activated with so that it can pick
|
||||
* a mirror log type during activation. Do not use this for anything
|
||||
* else.
|
||||
*/
|
||||
if (mode && !strcmp(mode, "sh"))
|
||||
cmd->lockd_lv_sh = 1;
|
||||
|
||||
if (!mode)
|
||||
mode = "ex";
|
||||
|
||||
@ -2301,31 +2292,6 @@ static int _lockd_lv_thin(struct cmd_context *cmd, struct logical_volume *lv,
|
||||
pool_lv->lock_args, def_mode, flags);
|
||||
}
|
||||
|
||||
/*
|
||||
* Only the combination of dlm + corosync + cmirrord allows
|
||||
* mirror LVs to be activated in shared mode on multiple nodes.
|
||||
*/
|
||||
static int _lockd_lv_mirror(struct cmd_context *cmd, struct logical_volume *lv,
|
||||
const char *def_mode, uint32_t flags)
|
||||
{
|
||||
if (!strcmp(lv->vg->lock_type, "sanlock"))
|
||||
flags |= LDLV_MODE_NO_SH;
|
||||
|
||||
else if (!strcmp(lv->vg->lock_type, "dlm") && def_mode && !strcmp(def_mode, "sh")) {
|
||||
#ifdef CMIRRORD_PIDFILE
|
||||
if (!cmirrord_is_running()) {
|
||||
log_error("cmirrord must be running to activate an LV in shared mode.");
|
||||
return 0;
|
||||
}
|
||||
#else
|
||||
flags |= LDLV_MODE_NO_SH;
|
||||
#endif
|
||||
}
|
||||
|
||||
return lockd_lv_name(cmd, lv->vg, lv->name, &lv->lvid.id[1],
|
||||
lv->lock_args, def_mode, flags);
|
||||
}
|
||||
|
||||
/*
|
||||
* If the VG has no lock_type, then this function can return immediately.
|
||||
* The LV itself may have no lock (NULL lv->lock_args), but the lock request
|
||||
@ -2379,14 +2345,12 @@ int lockd_lv(struct cmd_context *cmd, struct logical_volume *lv,
|
||||
*/
|
||||
if (lv_is_external_origin(lv) ||
|
||||
lv_is_thin_type(lv) ||
|
||||
lv_is_mirror_type(lv) ||
|
||||
lv_is_raid_type(lv) ||
|
||||
lv_is_cache_type(lv)) {
|
||||
flags |= LDLV_MODE_NO_SH;
|
||||
}
|
||||
|
||||
if (lv_is_mirror_type(lv))
|
||||
return _lockd_lv_mirror(cmd, lv, def_mode, flags);
|
||||
|
||||
return lockd_lv_name(cmd, lv->vg, lv->name, &lv->lvid.id[1],
|
||||
lv->lock_args, def_mode, flags);
|
||||
}
|
||||
|
@ -2056,18 +2056,6 @@ int lv_add_mirrors(struct cmd_context *cmd, struct logical_volume *lv,
|
||||
return 0;
|
||||
}
|
||||
|
||||
if (lv->vg->lock_type && !strcmp(lv->vg->lock_type, "dlm") && cmd->lockd_lv_sh) {
|
||||
if (!cluster_mirror_is_available(cmd)) {
|
||||
log_error("Shared cluster mirrors are not available.");
|
||||
return 0;
|
||||
}
|
||||
|
||||
if (log_count > 1) {
|
||||
log_error("Log type, \"mirrored\", is unavailable to cluster mirrors.");
|
||||
return 0;
|
||||
}
|
||||
}
|
||||
|
||||
/* For corelog mirror, activation code depends on
|
||||
* the global mirror_in_sync status. As we are adding
|
||||
* a new mirror, it should be set as 'out-of-sync'
|
||||
|
@ -278,15 +278,6 @@ static int _add_log(struct dm_pool *mem, struct lv_segment *seg,
|
||||
char *log_dlid = NULL;
|
||||
uint32_t log_flags = 0;
|
||||
|
||||
if (seg->lv->vg->lock_type && !strcmp(seg->lv->vg->lock_type, "dlm")) {
|
||||
/*
|
||||
* If shared lock was used due to -asy, then we set clustered
|
||||
* to use a clustered mirror log with cmirrod.
|
||||
*/
|
||||
if (seg->lv->vg->cmd->lockd_lv_sh)
|
||||
clustered = 1;
|
||||
}
|
||||
|
||||
if (seg->log_lv) {
|
||||
/* If disk log, use its UUID */
|
||||
if (!(log_dlid = build_dm_uuid(mem, seg->log_lv, NULL))) {
|
||||
|
@ -545,7 +545,7 @@ report an error and fail.
|
||||
The shared mode is intended for a multi-host/cluster application or
|
||||
file system.
|
||||
LV types that cannot be used concurrently
|
||||
from multiple hosts include thin, cache, raid, and snapshot.
|
||||
from multiple hosts include thin, cache, raid, mirror, and snapshot.
|
||||
|
||||
.IP \fBn\fP
|
||||
The command deactivates the LV. After deactivating the LV, the command
|
||||
|