IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
commit 15da467b was meant to address the case where
use_lvmetad=1 in lvm.conf, and lvmetad is not available,
in which case, pvscan --cache -aay should activate LVs.
But the commit unintentionally also changed the case
where use_lvmetad=0 in lvm.conf, in which case
pvscan --cache -aay should not activate LVs, so fix
that here.
When pvscan --cache -aay fails to connect to lvmetad it will
simply exit and do nothing. Change this so that it will
skip the lvmetad cache step and do the activation step from
disk.
A number of places are working on a specific dev when they
call lvmcache_info_from_pvid() to look up an info struct
based on a pvid. In those cases, pass the dev being used
to lvmcache_info_from_pvid(). When a dev is specified,
lvmcache_info_from_pvid() will verify that the cached
info it's using matches the dev being processed before
returning the info. Calling code will not mistakenly
get info for the wrong dev when duplicate devs exist.
This confusion was happening when scanning labels when
duplicate devs existed. label_read for the first dev
would add an info struct to lvmcache for that dev/pvid.
label_read for the second dev would see the pvid in
lvmcache from first dev, and mistakenly conclude that
the label_read from the second dev can be skipped
because it's already been done. By verifying that the
dev for the cached pvid matches the dev being read,
this mismatch is avoided and the label is actually read
from the second duplicate.
pvmove began processing tags unintentionally from commit,
6d7dc87cb pvmove: use toollib
pvmove works on a single PV, but tags can match multiple PVs.
If we allowed tags, but processed only the first matching PV,
then the resulting PV would be unpredictable.
Also, the current processing code does not allow us to simply
report an error and do nothing if more than one PV matches the tag,
because the command starts processing PVs as they are found,
so it's too late to do nothing if a second PV matches.
If configuration consists of several sources in config cascade
("config cascade" defined in man lvmconfig(8)), lvmconfig displayed
only difference from defaults of the topmost config in the cascade.
Fix lvmconfig to display complete difference, considering all
the configuration in the cascade.
For example, before this patch:
(use_lvmetad=0 set in lvm.conf which differs from defaults)
$ lvmconfig --type diff
global {
use_lvmetad=0
}
(compact_output=1 set on cmd line)
$ lvmconfig --type diff --config report/compact_output=1
report {
compact_output=1
}
(headings=0 set in profile)
$ lvmconfig --type diff --commandprofile test
report {
headings=0
}
(difference in topmost configuration source is displayed)
$ lvmconfig --type diff --commandprofile test --config report/compact_output=1
report {
compact_output=1
}
With this patch applied (the config cascade is merged before looking for
difference from defaults in configuration):
$ lvmconfig --type diff
global {
use_lvmetad=0
}
$ lvmconfig --type diff --config report/compact_output=1
report {
compact_output=1
}
global {
use_lvmetad=0
}
$ lvmconfig --type diff --profile test
report {
headings=0
}
global {
use_lvmetad=0
}
$ lvmconfig --type diff --profile test --config report/compact_output=1
report {
headings=0
compact_output=1
}
global {
use_lvmetad=0
}
In the same way that process_each_vg() can be passed
a single VG name to process, also allow process_each_lv()
to be passed a single VG name and LV name to process.
This refactors the code for autoactivation. Previously,
as each PV was found, it would be sent to lvmetad, and
the VG would be autoactivated using a non-standard VG
processing function (the "activation_handler") called via
a function pointer from within the lvmetad notification path.
Now, any scanning that the command needs to do (scanning
only the named device args, or scanning all devices when
there are no args), is done first, before any activation
is attempted. During the scans, the VG names are saved.
After scanning is complete, process_each_vg is used to do
autoactivation of the saved VG names. This makes pvscan
activation much more similar to activation done with
vgchange or lvchange.
The separate autoactivate phase also means that if lvmetad
is disabled (either before or during the scan), the command
can continue with the activation step by simply not using
lvmetad and reverting to disk scanning to do the
activation.
Add support for active cache LV.
Handle --cachemode args validation during command line processing.
Rework some lvm2 internal to use lvm2 defined CACHE_MODE enums
indepently on libdm defines and use enum around the code instead
of passing and comparing strings.
The _report fn is getting big - separate it in two:
- _report fn to get all the options and arguments
- _do_report fn for reporting itself
Also, place all the variables/arguments in one structure for easier
handling of the variables around.
Previously, duplicate PVs were processed as a side effect
of processing the "chosen" PV in lvmcache. The duplicate
PV would be hacked into lvmcache temporarily in place of
the chosen PV.
In the old way, we had to always process the "chosen" PV
device, even if a duplicate of it was named on the command
line. This meant we were processing a different device than
was asked for. This could be worked around by naming
multiple duplicate devs on the command line in which case
they were swapped in and out of lvmcache for processing.
Now, the duplicate devs are processed directly in their
own processing loop. This means we can remove the old
hacks related to processing dups as a side effect of
processing the chosen device. We can now simply process
the device that was named on the command line.
When the same PVID exists on two or more devices, one device
is preferred and used in the VG, and the others are duplicates
and are not used in the VG. The preferred device exists in
lvmcache as usual. The duplicates exist in a specical list
of unused duplicate devices.
The duplicate devs have the "d" attribute and the "duplicate"
reporting field displays "duplicate" for them.
'pvs' warns about duplicates, but the formal output only
includes the single preferred PV.
'pvs -a' has the same warnings, and the duplicate devs are
included in the output.
'pvs <path>' has the same warnings, and displays the named
device, whether it is preferred or a duplicate.
Wait to compare and choose alternate duplicate devices until
after all devices are scanned. During scanning, the first
duplicate dev is kept in lvmcache, and others are kept in a
new list (_found_duplicate_devs).
After all devices are scanned, compare all the duplicates
available for a given PVID and decide which is best.
If the dev used in lvmcache is changed, drop the old dev
from lvmcache entirely and rescan the replacement dev.
Previously the VG metadata from the old dev was kept in
lvmcache and only the dev was replaced.
A new config setting devices/allow_changes_with_duplicate_pvs
can be set to 0 which disallows modifying a VG or activating
LVs in it when the VG contains PVs with duplicate devices.
Set to 1 is the old behavior which allowed the VG to be
changed.
The logic for which of two devs is preferred has changed.
The primary goal is to choose a device that is currently
in use if the other isn't, e.g. by an active LV.
. prefer dev with fs mounted if the other doesn't, else
. prefer dev that is dm if the other isn't, else
. prefer dev in subsystem if the other isn't
If neither device is preferred by these rules, then don't
change devices in lvmcache, leaving the one that was found
first.
The previous logic for preferring a device was:
. prefer dev in subsystem if the other isn't, else
. prefer dev without holders if the other has holders, else
. prefer dev that is dm if the other isn't
Rather than doing repeated translations from name to
device when comparing args to existing PVs, do one
translation of the arg names and saving the device,
before checking existing PVs.
pvscan autoactivation has its own VG processing implementation,
so it can't properly handle things like foreign or shared VGs,
so make it ignore those VG types (or errors from them) as best
as possible.
Add a FIXME stating that pvscan autoactivation must really be
moved to the standard VG processing by calling process_each_vg
to do activation once the scanning / cache update is finished.
The lvmetad connection is created within the
init_connections() path during command startup,
rather than via the old lvmetad_active() check.
The old lvmetad_active() checks are replaced
with lvmetad_used() which is a simple check that
tests if the command is using/connected to lvmetad.
The old lvmetad_set_active(cmd, 0) calls, which
stopped the command from using lvmetad (to revert to
disk scanning), are replaced with lvmetad_make_unused(cmd).
Commands already check if the lvmetad token is valid,
and if not, they rescan devices to repopulate lvmetad
before running. Now, in addition to checking the
lvmetad token, they also check if the lvmetad disabled
flag is set. If so, they do not use the lvmetad cache
and revert to disk scanning.
process_each_pv was doing:
1. lvmcache_seed_infos_from_lvmetad()
sends pv_list request to lvmetad.
2. get_vgnameids()
sends vg_list request to lvmetad.
3. _get_all_devices()
first calls lvmcache_seed_infos_from_lvmetad(),
which is a no-op if it's already been called.
Because get_vgnameids() does not use the information
from lvmcache_seed_infos_from_lvmetad(), it does not
need to be called prior to get_all_devices where
it is actually needed.
Commit 971ab733b7 ("thin: activation of
merging thin snapshot") also added an incorrect deactivation attempt
for non-thin LVs: find_snapshot(lv)->lv is not designed to be
activated and any attempt to deactivate it is incorrect.
Move checking the lvmetad state, and the possible rescan,
out of lvmetad_send() to the start of the command.
Previously, the token mismatch and rescan would occur
within lvmetad_send() for some other request. Now,
the token mismatch is detected earlier, so the
rescan can be done before the main command is in
progress. Rescanning deep within the processing of
another command will disturb the lvmcache state of
that other command.
A rescan already exists at the start of the command
for the case where foreign VGs are going to be read.
This same rescan is now also performed when there is
an lvmetad token mismatch (from a changed global_filter).
The commands pvscan/vgscan/lvscan/vgimport are excluded
from this preemptive checking/rescanning for lvmetad
because they want to do rescanning themselves explicitly.
If rescanning devices fails, then lvmetad has not been
correctly repopulated and should not be used, so make
the command revert to not using lvmetad.