IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Each integrity image in a raid LV reports its own number
of integrity mismatches, e.g.
lvs -o integritymismatches vg/lv_rimage_0
lvs -o integritymismatches vg/lv_rimage_1
In addition to this, allow the total number of integrity
mismatches from all images to be displayed for the raid LV.
lvs -o integritymismatches vg/lv
shows the number of mismatches from both lv_rimage_0 and
lv_rimage_1.
In some cases the dev size may not have been read yet
in set_pv_devices(). In this case get the dev size
before comparing the dev size with the pv size.
Since BLKZEROOUT ioctl should be supposedly fastest
way how to clear block device start using this ioctl
for zeroing a device. Commonly we do zero typically
small portion of a device (8KiB) - however since we now
also started to zero metadata devices, in the case
of i.e. thin-pool metadata this can go upto ~16GiB
and here the performance starts to be noticable.
Since dev_set_bytes() now closes dev on error path itself,
remove this unneeded call now (introduced few commits back
in history thus removing comment from WHATS_NEW)
When detaching a writecache, use the cleaner setting
by default to writeback data prior to suspending the
lv to detach the writecache. This avoids potentially
blocking for a long period with the device suspended.
Detaching a writecache first sets the cleaner option, waits
for a short period of time (less than a second), and checks
if the writecache has quickly become clean. If so, the
writecache is detached immediately. This optimizes the case
where little writeback is needed.
If the writecache does not quickly become clean, then the
detach command leaves the writecache attached with the
cleaner option set. This leaves the LV in the same state
as if the user had set the cleaner option directly with
lvchange --cachesettings cleaner=1 LV.
After leaving the LV with the cleaner option set, the
detach command will wait and watch the writeback progress,
and will finally detach the writecache when the writeback
is finished. The detach command does not need to wait
during the writeback phase, and can be canceled, in which
case the LV will remain with the writecache attached and
the cleaner option set. When the user runs the detach
command again it will complete the detach.
To detach a writecache directly, without using the cleaner
step (which has been the approach previously), add the
option --cachesettings cleaner=0 to the detach command.
Introduce structures lv_status_thin_pool and
lv_status_thin (pair to lv_status_cache, lv_status_vdo)
Convert lv_thin_percent() -> lv_thin_status()
and lv_thin_pool_percent() + lv_thin_pool_transaction_id() ->
lv_thin_pool_status().
This way a function user can see not only percentages, but also
other important status info about thin-pool.
TODO:
This patch tries to not change too many other things,
but pool_below_threshold() now uses new thin-pool info to return
failure if thin-pool cannot be actually modified.
This should be handle separately in a better way.
Improve error response and reporting, when creating thin snapshots.
If the thin pool kernel metadata already have device with ID lvm2
tries to create, give more meanigful error message and also properly
restore transaction id to the value known to thin-pool in this case.
Before it's been possible to divert by one from kernel TID value,
and lvm2 stacked delete message for such thin device.
Since ATM kernel does not support this operation,
disable 'lvrename' of an active vdopool.
As a workaround, user may simply deactivate, rename and activate.
When user tries to extend vdo pool - he needs to go always
at least by 1 full VDO slab (defined as vdo_slab_size_mb).
To avoid all trouble around find 'workable' size - lvm2 automatically
increases the passed (or by --use-policies calculated) extension size
(and informs a user about sometimes possibly large increase as slab
size can go upto 32GiB)
With VDO users need to always 'think-big' anyway and expect such
operation to be in GiB domain range.
When thetable reload fails during suspend() - we were only calling
plain resume() - and this will reload only those devices,
which were left suspend, but will not try to restore
metadata state according to lvm2 reverted metadata.
So if we were reloading device tree - we have restored
only top-level LV and rest of reverted device manipulation
were left alone and possibly mismatched what is in committed
metadata.
FIXME: There are several cases were such revert will likely not work
properly anyway as some operation are currenly handled in single commit,
while they need multiple commits, but it's step towards better correctness.
At least we catch there errors now earlier.
lvm opens devices readonly to scan them, but
needs to open then readwrite to update the metadata.
Previously, the ro fd was closed before the rw fd
was opened, leaving a small gap where the dev was
not held open, and during which the dev could
possibly change which storage it referred to.
With the bcache_change_fd() interface, lvm opens a
rw fd on a device to be written, tells bcache to
change to the new rw fd, and closes the ro fd.
. open dev ro
. read dev with the ro fd (label_scan)
. lock vg (ex for writing)
. open dev rw
. close ro fd
. rescan dev to check if the metadata changed
between the scan and the lock
. if the metadata did change, reread in full
. write the metadata
Add a "device index" (di) for each device, and use this
in the bcache api to the rest of lvm. This replaces the
file descriptor (fd) in the api. The rest of lvm uses
new functions bcache_set_fd(), bcache_clear_fd(), and
bcache_change_fd() to control which fd bcache uses for
io to a particular device.
. lvm opens a dev and gets and fd.
fd = open(dev);
. lvm passes fd to the bcache layer and gets a di
to use in the bcache api for the dev.
di = bcache_set_fd(fd);
. lvm uses bcache functions, passing di for the dev.
bcache_write_bytes(di, ...), etc.
. bcache translates di to fd to do io.
. lvm closes the device and clears the di/fd bcache state.
close(fd);
bcache_clear_fd(di);
In the bcache layer, a di-to-fd translation table
(int *_fd_table) is added. When bcache needs to
perform io on a di, it uses _fd_table[di].
In the following commit, lvm will make use of the new
bcache_change_fd() function to change the fd that
bcache uses for the dev, without dropping cached blocks.
Metadata size was calculated correctly only for raids.
Fixes problem for crash during lvcreate when thin-pool was created
on a VG where remaining free space had the size to only fit a single
metadata LV and not also its _pmspare.
Lvcreate crashed with this assert message:
lvcreate: metadata/pv_map.c:198: consume_pv_area: Assertion `to_go <= pva->count' failed.
Aborted (core dumped)
TODO: there is probably to large overload of several alloc_handle
variables.
Reported-by: Wu Guanghao<wuguanghao3@huawei.com>
Reported-by: Zhiqiang Liu <liuzhiqiang26@huawei.com>
When using --use-policy for automatic extension of thin-pool,
the extension of thin-pool's metadata itself can actually take
some extra space.
Since I'm not aware of exact compensation formula, add just
1% extra to calculated amount and hope it fits.
Wanted target is to always have usable thin-pool that fits
bellow pool_metadata_min_threshold().
Since we query on regular code these:
lv_raid_has_integrity()
lv_has_integrity_recalculate_metadata()
without prior checking for lv_is_raid() - these 'return 0' should
not use <stacktrace> as they are expected.
Correcting rounding rules for percentage evaluation.
Validate supported range of percentage.
(although ranges are already validated earlier on code path)
Switch remaining zero sized struct to flexible arrays to be C99
complient.
These simple rules should apply:
- The incomplete array type must be the last element within the structure.
- There cannot be an array of structures that contain a flexible array member.
- Structures that contain a flexible array member cannot be used as a member of another structure.
- The structure must contain at least one named member in addition to the flexible array member.
Although some of the code pieces should be still improved.