On conversion from striped to raid0, data LVs are created
and all segments and their respective areas of the striped
LV are moved across to new segments allocated for the raid0
image LVs. This can cause non-canonical segments to be added
to the image LVs.
Add a call to lv_merge_segments() once all segments have been
added to an image LV to compensate for that. This avoids
unsafe table loads on activation.
Fix comments.
Automatic dmeventd repair of mirrors with active lvmetad configured
(mirror_image_fault_policy = "allocate") fails because the lvscan
run before the repair in the mirror DSO does not update the
lvmetad cache properly thus "lvconvert --repair ..." fails.
Need to scan the mirror LV before and after the repair
to have proper cache content after the repair finished.
The cache can't be relied on or the repair will fail.
Resolves: rhbz1380521
Launch an instance of the filemap monitoring daemon when creating,
or updating, a file mapped group, unless the --nomonitor switch is
given.
Unless --foreground is given the daemon will detach from the
terminal and run in the background until it is signaled or the
daemon termination conditions are met.
The --follow={inode|path} switch is added to control the daemon
behaviour when files are moved, unlinked, or renamed while they
are being monitored.
The daemon runs with the same verbosity as the dmstats command
that starts it.
Add a daemon that can be launched to monitor a group of regions
corresponding to the extents of a file, and to update the regions as the
file's allocation changes.
The daemon is intended to be started from a library interface, but can
also be run from the command line:
dmfilemapd <fd> <group_id> <path> <mode> [<foreground>[<log_level>]]
Where fd is a file descriptor open on the mapped file, group_id is the
group identifier of the mapped group and mode is either "inode" or
"path". E.g.:
# dmfilemapd 3 0 vm.img inode 1 3 3<vm.img
...
If foreground is non-zero, the daemon will not fork to run in the
background. If verbose is non-zero, libdm and daemon log messages will
be printed.
It is possible for the group identifier to change when regions are
re-mapped: this occurs when the group leader is deleted (regroup=1 in
dm_stats_update_regions_from_fd()), and another region is created before
the daemon has a chance to recreate the leader region.
The operation is inherently racey since there is currently no way to
atomically move or resize a dm_stats region while retaining its
region_id.
Detect this condition and update the group_id value stored in the
filemap monitor.
A function is also provided in the the stats API to launch the filemap
monitoring daemon:
int dm_stats_start_filemapd(int fd, uint64_t group_id, const char *path,
dm_filemapd_mode_t mode, unsigned foreground,
unsigned verbose);
This carries out the first fork and execs dmfilemapd with the arguments
specified.
A dm_filemapd_mode_t value is specified by the mode argument: either
DM_FILEMAPD_FOLLOW_INODE, or DM_FILEMAPD_FOLLOW_PATH. A helper function,
dm_filemapd_mode_from_string(), is provided to parse a string containing
a valid mode name into the appropriate dm_filemapd_mode_t value.
It's not an error to call dm_stats_group_present() on a handle
that contains no regions.
This causes dmfilemap to log a false backtrace during shutdown
if all regions are removed from the corresponding device:
exiting _filemap_monitor_get_events() with deleted=0, check=0
waiting for FILEMAPD_WAIT
dm message (253:1) [ opencount flush ] @stats_list dmstats [32768] (*1)
<backtrace>
Filemap group removed: exiting.
Change this to only emit a backtrace if the handle is NULL.
Splitting off an image LV of a 2-legged
raid1 LV causes loss of resilience.
Ask user to avoid uninformed loss of all resilience.
Don't ask for N > 2 legged raid1 LVs.
Adjust tests.
Splitting off an image LV of a 2-legged raid1 LV tracking changes
causes loosing partial resilience for any newly written data set.
Full resilience will be provided again after the split off image LV
got merged back in and the new data set got fully synchronized.
Reason being that the data is only stored on the remaining single
writable image during the split.
Ask user to avoid uninformed loss of such partial resilience.
Don't ask for N > 2 legged raid1 LVs.
In case N images fail (N <= parity chunks) _and_
a "vgreduce --removemissing --force VG" was applied
a following repair of the RaidLV fails:
Unable to remove N images: Only 0 devices given.
Failed to remove the specified images from tb/r.
Failed to replace faulty devices in tb/r.
Fix as of this commit results in correct repair:
Faulty devices in tb/r successfully replaced.
Add new values for different sign variations, resulting in:
size_VAL no sign accepted
ssize_VAL accepts + or -
psize_VAL accepts +
nsize_VAL accpets -
extents_VAL no sign accepted
sextents_VAL accepts + or -
pextents_VAL accepts +
nextents_VAL accepts -
Depending on the command being run, change the option
values for --size, --extents, --poolmetadatasize to
use the appropriate value from above.
lvcreate uses no sign (but accepts + and ignores it).
lvresize accepts +|- for a relative change.
lvextend accepts + for a relative change.
lvreduce accepts - for a relative change.
Like opt and val arrays in previous commit, combine duplicate
arrays for lv types and props in command.c and lvmcmdline.c.
Also move the command_names array to be defined in command.c
so it's consistent with the others.
command.c and lvmcmdline.c each had a full array defining
all options and values. This duplication was not removed
when the command.c code was merged into the run time.
seg->extents_copied has to be defined properly on reducing
the size of a raid LV or conversion from raid5 with 1 stripe
to raid1 will fail.
Related: rhbz834579
Related: rhbz1191935
Related: rhbz1191978
Reshaping a raid5 LV to one stripe aiming to convert it to
raid1 (and optionally to linear) reports the wrong LV size
when still having reshape space allocated.
The lv_extend/_lv_reduce API doesn't cope with resizing RaidLVs
with allocated reshape space and ongoing conversions. Prohibit
resizing during conversions and remove the reshape space before
processing resize. Add missing seg->data_copies initialisation.
Fix typo/comment.
For the time being raid10 is limited to even number of total stripes
as is and 2 data copies. The number of stripes provided on creation
of a raid10(_near) LV with -i/--stripes gets doubled to define
that even total number of stripes (i.e. images).
Apply the same on disk adding conversions (reshapes) with
"lvconvert --stripes RaidLV" (e.g. 2 stripes = 4 images
total converted to 3 stripes = 6 images total).
Related: rhbz834579
Related: rhbz1191935
Related: rhbz1191978
Part of the UNIT description was still living in the
--size description. Move it to the Size[UNIT] description
since it is used by other options, not just --size.
In lvcreate/lvconvert, --poolmetdatasize can only be an
absolute value, but in lvresize/lvextend, --poolmetadatasize
can be given a + relative value.
The val types only currently support relative values that
go in both directions +|-. Further work is needed to add
val types that can be relative in only one direction, and
switching various option values to one those depending on
the command name. Then poolmetdatasize will not appear
with a +|- option in lvcreate/lvconvert, and will
appear with only the + option in lvresize/lvextend.
Enhance the raid report functions for the recently added LV fields
reshape_len, reshape_len_le, data_offset, new_data_offset, data_copies,
data_stripes and parity_chunks to cope with "lvs --select".
Related: rhbz834579
Related: rhbz1191935
Related: rhbz1191978