Added a properties changed signal on the job dbus object so that client
can wait for a signal that the job is complete instead of polling or
blocking on the wait method.
Allows the user to override the number of commands that get dumped
to the log when we encounter a lvm error. Also useful during
development when you don't want to see the blackbox output.
When reading data from stdout & stderr we were reading until the
reading until we got None back which really isn't needed as the
read will return everything that is available.
We need to acquire a lock which can block us which in turn causes
the dbus request handling to block as well. Place the request on
the work queue instead.
Our expectation was that when using the lvm shell that when the lvm prompt
was read from stdout, that all other ouput had been written and flushed.
However, this doesn't appear to be the case. Add extra read passes to
retrieve delayed report data.
In preparation to have more than one thread issuing commands to lvm
at the same time we need to serialize updates to the dbus state and
retrieving the global lvm state. To achieve this we have one thread
handling this with a thread safe queue taking and coalescing requests.
This code is no longer needed because the back ground task has been
removed. Will add back if we change the design and end up utilizing
multiple worker threads.
There is no reason to create another background task when the task that
created it is going to block waiting for it to finish. Instead we will
just execute the logic in the worker thread that is servicing the worker
queue.
Instead of creating a thread to handle the case where a client
is calling job.Wait, we will utilize a timer. This significantly
reduces the number of threads that get created and destroyed while
the service is running.
We will fetch the lvm state in non-main thread and only process the new
data with the main thread to prevent hanging the main thread event loop.
ref. https://bugs.freedesktop.org/show_bug.cgi?id=98521
The following LvCommon properties were added so that the API
would have the same functionality as lvm2app has.
LvCommon.MetaDataSizeBytes
LvCommon.Attr
LvCommon.MetaDataPercent
LvCommon.CopyPercent
LvCommon.SnapPercent
LvCommon.SyncPercent
When a PV device is missing lvm will return '[unknown]' for the device
path. The object manager keeps a hash table lookup for uuid and for PV's
device name. When we had multiple PVs with the same device path we
we only had 1 key in the table for the lvm id (device path). This caused
a problem when the PV device transitioned from '[unknown]' to known as any
subsequent transitions would cause an exception:
Traceback (most recent call last):
File "/usr/lib/python3.5/site-packages/lvmdbusd/request.py", line 66, in run_cmd
result = self.method(*self.arguments)
File "/usr/lib/python3.5/site-packages/lvmdbusd/manager.py", line 205, in _pv_scan
cfg.load()
File "/usr/lib/python3.5/site-packages/lvmdbusd/fetch.py", line 24, in load
cache_refresh=False)[1]
File "/usr/lib/python3.5/site-packages/lvmdbusd/pv.py", line 48, in load_pvs
emit_signal, cache_refresh)
File "/usr/lib/python3.5/site-packages/lvmdbusd/loader.py", line 80, in common
cfg.om.remove_object(cfg.om.get_object_by_path(k), True)
File "/usr/lib/python3.5/site-packages/lvmdbusd/objectmanager.py", line 153, in remove_object
self._lookup_remove(path)
File "/usr/lib/python3.5/site-packages/lvmdbusd/objectmanager.py", line 97, in _lookup_remove
del self._id_to_object_path[lvm_id]
KeyError: '[unknown]'
when trying to delete a key that wasn't present. In this case we don't add a
lookup key for the device path and the PV can only be located by UUID.
Ref: https://bugzilla.redhat.com/show_bug.cgi?id=1379357
Gris debugged that when we don't have a method the introspection
data is missing the interface itself eg.
<interface name="<your_obj_iface_name>" />
When adding the properties to the dbus object introspection we will
add the interface too if it's missing. This now allows us the
ability to have a dbus object with only properties.
When we register a failure we need to use a valid value which will be
returned with the object manager. Otherwise we will raise an Exception
because we are trying to construct an object path from None.