There are kernel drivers (smblk) which set '-1' as their device major number.
This number is listed in /proc/devices then - but the kernel itself is using
just 12 bits - thus device is accessible via 4095 - there is posted patch
for 3.4 to fix this behavior (0 for auto allocation was mean to be used).
However to still allow using such devices with older kernels add some code
to use same behavior - so cut 12 bits from the major number from /proc/devices.
For now use log_warn() - maybe the severity of the message could be lowered
to just verbose level.
Save some relocation entries and use directly char[].
Since we do not need yes more then 127 partitions per device, use just int8_t.
Move lvm_type_filter_destroy into local static function.
"result_independent_of_operands: ((dev->dev & 0xfff00UL) >> 8) ==
18446744073709551615UL /* -1 */ is always false regardless of the values
of its operands (logical operand of if)."
'dev->dev' is set in dev-cache.c _insert() and it's not expectable
st_rdev would have '-1'
This code has been introduced with drbd support commit and code never
worked - so eliminated.
Add filter which tries to check if scanned device is part
of active multipath.
Firstly, only SCSI major number devices are handled in filter.
Then it checks if device has exactly one holder (in sysfs) and
if it is device-mapper device and DM-UUID is prefixed by "MPATH-".
If so, this device is filtered out.
The whole filter can be switched off by setting
mpath_component_detection in lvm.conf.
https://bugzilla.redhat.com/show_bug.cgi?id=597010
Signed-off-by: Milan Broz <mbroz@redhat.com>
leaving behind the LVM-specific parts of the code (convenience wrappers that
handle `struct device` and `struct cmd_context`, basically). A number of
functions have been renamed (in addition to getting a dm_ prefix) -- namely,
all of the config interface now has a dm_config_ prefix.
Add configurable option to define minimal size of
of block device usable as a PV.
pv_min_size() is added to lvm-globals and it's being
initialized through _process_config.
Macro PV_MIN_SIZE is unused and removed.
New define DEFAULT_PV_MIN_SIZE_KB is added to lvm-global
and unlike PV_MIN_SIZE it uses KB units.
Should help users with various slow devices attached to the system,
which cannot be easily filtered out (like FDD on /dev/sdX):
https://bugzilla.redhat.com/show_bug.cgi?id=644578
To have better control were the config tree could be modified use more
const pointers and very carefully downcast them back to non-const
(for config tree merge).
We can already detect MD devices internally. But when using MD partitions,
these have "block extended major" (blkext) assigned (259). Blkext major
is also used in general, so we need to check whether the original device
is an MD device actually.
This should avoid various races between dmeventd on multiple nodes
in cluster where one node already repairing device and another
run full scan and locks the device.
The DRBD uses underlying device so code should prefer top
device if duplicate is found.
Patch also introduce
dev_subsystem_part_major and dev_subsytem_name
functions to easily handle all these replication susbystems
and not hardcode md_major call.
See https://bugzilla.redhat.com/show_bug.cgi?id=530881
for full problem description.
Eliminate busy loop during pvcreate of a "normal" partition.
_md_sysfs_attribute_snprintf() would busy loop if the device it was
given was not a blkext-based MD partition.
Rather than being cute with a busy-loop prone 'goto check_md_major' in
_md_sysfs_attribute_snprintf(): explicitly check if the provided device
is a blkext-based partition (blkext_major()); and then check that the
get_primary_dev() determined parent is an MD device (md_major()).
Fix some memory leaks in error paths found by coverity.
Use C99 struct initialisers.
Move DEFS into configure.h.
Clean-ups to remove miscellaneous compiler warnings.