IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Improve code for snapshot merge for readabilty
and also reduce number of tests needed to decide
if merging can or cannot be started.
(Further improving 9cccf5245a)
To recognize in runtime if we are merging or not
to make consistent decision between suspend and resume
add function to parse thin table line when add
merging thin device to the table.
A snapshot merge into its origin cannot be initiated while the devices
are in use. If there is outside interference (such as from udev),
the suspend (preload) and resume stages can reach conflicting decisions
about whether or not to proceed.
Try to make the logic more robust by checking the inactive or live
table during resume. (This is still not perfect.)
When scanning if device is being usable as PV,
we call STATUS - but this status should not cause
any flushing.
Skip also open_count information as it's not needed.
Devices without "LVM-" uuid prefix have been generated by very old
version of lvm2 2.00 and 2.01.
Since version 2.02 all lvm2 devices are using prefix "LVM-".
However checking for present of ancient non prefixed devices does
take extra IOCTL per every call and for majority of todays user
it will not find anything new.
So use the assumption that users with kernel 3.X and newer are not
really using such old versions of lvm2 (year <2005) and with their
new kernel they are also using new version of lvm2 and skip
checking for them.
This change also makes trace logs more readable.
When leaving preload routine it should not altet state of flush required
when it's been already set to 1 and drop it to 0.
The API here is unclean, but current usage expects the same
variable pointer is for all preload calls and combines 'flush_required'
across all of them.
Commit 844b009584 tried to move
limit for usage of noflush to 'preload' however this was not
correctly processed.
Intead explicitly check for which types we do not want noflush
and also add debug message in this case.
Fix regression caused by commit ba41ee1dc9.
The idea was to use no_flush for changed device only for thin volumes
and thin pools but also to merge this with change made in commit
844b009584.
However the resulting condition has caused misbehavior for the mirror
suspend - as that has been before the ONLY allowed target type
that could have been suspended with noflush.
Result was badly working repair for --type mirror that has been
passing 'flush' to the repaired mirror target whenever preload
wrongly set flush_required.
The origin code has required the flush_required to be set whenever
deivce size is changed.
Now it first detects if device size got smaller
'dm_tree_node_size_changed(root) < 0' - this requires flush.
Otherwise it checks device is not thin volume nor thin pool and its
size has changed (got bigger) and requires flush.
This mean upsize of thin-pool or thin volume will not require flush.
Use meta% to expose highest mapped sector in thinLV.
so showing there 100.00% means thinLV maps latest sector.
Currently using a 'trick' with total_numerator to pass-in
device size when 'seg==NULL'
TODO: Improve device status API per target - current 'percentage'
is not really extensible.
Previous fix missed the fact the we do query for 'percent' with
seg value either set or unset (API overload...)
When 'seg' was unset, we still issue flush with status.
Fix it by cheking segtype by target_type.
As we check for segtype - we could also skip whole percentage
if the 'segtype' is unknown by code directly.
Reported-by: Ming-Hung Tsai <mingnus gmail com
Currently it's been checked for 'zero' header for thin-pool,
but lets use it always for cache as well - since it's relatively 'cheap'
detection of read 'error' problems as thin/cache tools
currently do not work fast enough in this case.
Fix reporting of Fail thin-pool target status
as attr[8] letter 'F'.
Report 'needs_check' status from thin-pool target via
attr field [4] (letter 'c'/'C'), and also via CheckNeeded field.
TODO: think about better name here?
TODO: lots of prop_not_implemented_set
Remove long outstand unused code lines, which were already
been obsoleted by other code.
Statuses and snapshot tree creation is already handled differently.
Also drop some 'extra' log_error() and use only stack;
since error has already been reported.
Since we do not use dev_manager in a way we would have destroyed VG
content while in-use - we could safely keep just pointer.
So dropping strdup.
Also it seems we actually no longer use vg_name for anything
so it may possibly go away completely unless it would be useful
for debugging...
When 'lvextend -L+XX vg/thinpool' do not leave inactive table
loaded for 'wrapping' LV on top of resized thin-pool
(ATM we use linear LV for this with same size as thin-pool).
Coverity noticed this condition is always false and the error
path could never be visited.
So check for all mismatches of supported messages
and actually mark log_error as internal error.
Recognize the target only 'extends' and do not enforce
'flush' in this case. Only the size reduction
still requires flush (so disables usage of no_flush flag).
If some other targets do require flush before suspend,
they have to explicitly ask for it.
While the activation code tries to evaluate which target
really needs flush with suspend and which may go without flush,
it has stayed effectively disabled by original commit:
33f732c5e9 since here
it only allows to pass non-pvmoving 'mirrors'.
So remove check for mirror LV type and only disable
no_flush for 'pvmove'..
TODO: Looking into history - it also seemed like raid target
would have always required flushing but it's been later
removed without clean explanation.
If some more targets really do need 'no_flush' it should
been handle at their 'level' - since we now stack multiple
targets over itself.
Since we may easily get blocked when checking for percentage
of thin-pool - do not flush and just show current values.
This avoids holding VG locked when pool is overfilled.
Try to detect thin-pool which my block lvm2 command from furher
processing (i.e. lvextend).
Check if pool is read-only or out-of-space and in this case thins
will skipped from being scanned (so user may miss some PVs located
on thin volumes).
Require global/{thin,cache}_{check,repair}_options to be always defined.
If not defined directly by user in the configuration and if there's no
concrete default option to use, make "" (empty string) the default one -
it's then clearly visible in the "lvmconfig --type default" (and
generated lvm.conf) and also it makes its handling in the code more
straightforward so we don't need to handle undefined values.
This means, if there are no default values for these settings defined,
we end up with this generated now:
{thin,cache}_{check,repair}_options = [ "" ]
So the value is never undefined and if it is, it's an error.
(The cache_repair_options is actually not used in the code at the moment,
but once the code using this setting is in, it will follow the same logic
as used for thin_repair_options.)