CONVERTING status flag is a tricky one. It's not set when converting
a non-mirror LV type to the mirror type, i.e.: linear -> two leg mirror.
Also the conversion itself is instant and doesn't require to be polled.
When mirror reaches sync state there's no final update on VG metadata
for lvmpolld to be made thereby report_progress in fact doesn't report
percentage of mirror being converted but percentage of mirror
being in sync. Perhaps we should reword the lvconvert output here.
On the other hand CONVERTING is set while we upconvert the mirror
from i.e. two leg mirror to four leg mirror. In such case the operation
is required to be polled so that lvmpolld can cleanup temporary
conversion log when the conversion is over.
Ignore CONVERTING lv_type for the moment and match LVs only by uuids
during 'mirror conversion'/'waiting for a sync to finish'.
The old code made two loops through the PVs: in the first
loop it found the max PV and VG name lengths, and in the
second loop it printed each PV using the name lengths as
field widths for aligning columns.
The new code uses process_each_pv() which makes one loop
through the PVs. In the *first* call to pvscan_single(),
the max name lengths are found by looping through the
lvmcache entries which have been populated by the generic
process_each code prior to calling any _single functions.
Subsequent calls to pvscan_single() reuse the max lengths
that were found by the first call.
The new report/compact_output_cols setting has exactly the same effect
as report/compact_output setting. The difference is that with the new
setting it's possible to define which cols should be compacted exactly
in contrast to all cols in case of report/compact_output.
In case both compact_output and compact_output_cols is enabled/set,
the compact_output prevails.
For example:
$ lvmconfig --type full report/compact_output report/compact_output_cols
compact_output=0
compact_output_cols=""
$ lvs vg
LV VG Attr LSize Pool Origin Data% Meta% Move Log Cpy%Sync Convert
lvol0 vg -wi-a----- 4.00m
---
$ lvmconfig --type full report/compact_output report/compact_output_cols
compact_output=0
compact_output_cols="data_percent,metadata_percent,pool_lv,move_pv,origin"
$ lvs vg
LV VG Attr LSize Log Cpy%Sync Convert
lvol0 vg -wi-a----- 4.00m
---
$ lvmconfig --type full report/compact_output report/compact_output_cols
compact_output=1
compact_output_cols="data_percent,metadata_percent,pool_lv,move_pv,origin"
$ lvs vg
LV VG Attr LSize
lvol0 vg -wi-a----- 4.00m
dm_report_compact_given_fields is the same as dm_report_compact_fields,
but it processes only given fields, not all the fields in the report
like dm_report_compact_field does.
If a host failed while holding a sanlock lease,
sanlock_acquire will by default block and wait
for the lease to expire before returning. We
want it to return with an error so we can retry
instead of blocking, which allows us to process
other lock operations.
(Enclose this in an ifdef until the new flag
appears in a sanlock release.)
Respect lvm2_log_fn prototype. The idea of 'reusing' print_log with
plain cast is causing very strange crashes with some older 'gcc' compilers.
So just do it cleanly...
This reverts commit 1b1c01a27b.
This caused messages to get dropped instead of logged into the log file.
(The log file and log function are independent at the moment.)
Rework thread creation code to better use resources.
New code will not leak 'timeout' registered thread on error path.
Also if the thread already exist - avoid creation of thread
object and it's later destruction.
If the race is noticed during adding new monitoring thread,
such thread is put on cleanup list and -EEXIST is reported.
As we now use 'unified' logging macro system - we no longer need
to protect from change of logging function pointer - it's set
once at the start of dmeventd and not change anymore
(as lvm2 library no longer interferers here).