IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
The pv_by_path might be also dangerous to use as it does not
count with any other metadata areas but the ones found on the PV
itself. If metadata was not found on the PV referenced by the path,
it returned no PV though it might have been referenced by metadata
elsewhere (on other PVs...).
If extending a VG and including a PV with 0 MDAs that was already
a part of a VG, the vgextend allowed that PV to be added and we
ended up *with one PV in two VGs*!
The vgextend code used the 'pv_by_path' fn that returned a PV for
a given path. However, when the PV did not have any metadata areas,
the fn just returned a PV without any reference to existing VG.
Consequently, any checks for the existing VG failed.
[0] raw/~ # pvcreate --metadatacopies 0 /dev/sda
Physical volume "/dev/sda" successfully created
[0] raw/~ # pvcreate --metadatacopies 1 /dev/sdb
Physical volume "/dev/sdb" successfully created
[0] raw/~ # vgcreate vg1 /dev/sda /dev/sdb
Volume group "vg1" successfully created
[0] raw/~ # pvcreate --metadatacopies 1 /dev/sdc
Physical volume "/dev/sdc" successfully created
[0] raw/~ # vgcreate vg2 /dev/sdc
Volume group "vg2" successfully created
Before this patch (incorrect):
[0] raw/~ # vgextend vg2 /dev/sda
Volume group "vg2" successfully extended
With this patch (correct):
[0] raw/~ # vgextend vg2 /dev/sda
Physical volume '/dev/sda' is already in volume group 'vg1'
Unable to add physical volume '/dev/sda' to volume group 'vg2'.
Before, the find_pv_by_name call always failed if the PV found was orphan.
However, we might use this function even for a PV that is not part of any VG.
This patch adds 'allow_orphan' arg to find_pv_by_name fn that allows that.
_find_pv_by_name -> find_pv_by_name
_find_pv_in_vg -> find_pv_in_vg
_find_pv_in_vg_by_uuid -> find_pv_in_vg_by_uuid
The only callers of the underscored variants were their wrappers
without the underscore. No other part of the code referenced the
underscored variants.
Keep the flag whether given thin pool argument has been given on command
line or it's been 'estimated'
Call of update_pool_params() must not change cmdline given args and
needs to know this info.
Since there is a need to move this update function into /lib, we cannot
use arg_count().
FIXME: we need some generic mechanism here.
For example, the old call and reference:
find_config_tree_str(cmd, "devices/dir", DEFAULT_DEV_DIR)
...now becomes:
find_config_tree_str(cmd, devices_dir_CFG)
So we're referring to the named configuration ID instead
of passing the configuration path and the default value
is taken from central config definition in config_settings.h
automatically.
The PV header extension information (PV header extension version, flags
and list of Embedding Area locations) is stored just beyond the PV header base.
When calculating the Embedding Area start value (ea_start), the same logic is
used as when calculating the pe_start value for Data Area - the value must
follow exactly the same alignment restrictions for its start value
(the alignment detected automatically or provided via command line using
the --dataalignment and --dataalignmentoffset arguments).
The Embedding Area is placed at the very start of the PV, starting at
ea_start. The Data Area starting at pe_start is placed next. The pe_start is
still properly aligned. Due to the pe_start alignment, it's possible that the
resulting Embedding Area size (ea_size) ends up bigger in size than requested
(but never less than requested).
New tools with PV header extension support will read the extension
if it exists and it's not an error if it does not exist (so old PVs
will still work seamlessly with new tools).
Old tools without PV header extension support will just ignore any
extension.
As for the Embedding Area location information (its start and size),
there are actually two places where this is stored:
- PV header extension
- VG metadata
The VG metadata contains a copy of what's written in the PV header
extension about the Embedding Area location (NULL value is not copied):
physical_volumes {
pv0 {
id = "AkSSRf-difg-fCCZ-NjAN-qP49-1zzg-S0Fd4T"
device = "/dev/sda" # Hint only
status = ["ALLOCATABLE"]
flags = []
dev_size = 262144 # 128 Megabytes
pe_start = 67584
pe_count = 23 # 92 Megabytes
ea_start = 2048
ea_size = 65536 # 32 Megabytes
}
}
The new metadata fields are "ea_start" and "ea_size".
This is mostly useful when restoring the PV by using existing
metadata backups (e.g. pvcreate --restorefile ...).
New tools does not require these two fields to exist in VG metadata,
they're not compulsory. Therefore, reading old VG metadata which doesn't
contain any Embedding Area information will not end up with any kind
of error but only a debug message that the ea_start and ea_size values
were not found.
Old tools just ignore these extra fields in VG metadata.
PV header extension comes just beyond the existing PV header base:
PV header base (existing):
- uuid
- device size
- null-terminated list of Data Areas
- null-terminater list of MetaData Areas
PV header extension:
- extension version
- flags
- null-terminated list of Embedding Areas
This patch also adds "eas" (Embedding Areas) list to lvmcache (lvmcache_info)
and it also adds support for common operations on the list (just like for
already existing "das" - Data Areas list):
- lvmcache_add_ea
- lvmcache_update_eas
- lvmcache_foreach_ea
- lvmcache_del_eas
Also, add ea_start and ea_size to struct physical_volume for processing
PV Embedding Area location throughout the code (currently only one
Embedding Area is supported, though the definition on disk allows for
more if needed in the future...).
Also, define FMT_EAS format flag to mark that the format actually
supports Embedding Areas (currently format-text only).
Extract restorable PV creation parameters from struct pvcreate_params into
a separate struct pvcreate_restorable_params for clarity and also for better
maintainability when adding any new items later.
Use the field 'origin' for reporting external origin lv name.
For thin volumes with external origin, report the size of
external origin size via:
lvs -o+origin_size
If zero metadata copies are used, there's no further recalculation of
PV alignment that happens when adding metadata areas to the PV and
which actually calculates the alignment correctly as a matter of fact.
So fix this for "PV without MDA" case as well.
Before this patch:
[1] raw/~ # pvcreate --dataalignment 8m --dataalignmentoffset 4m
--metadatacopies 1 /dev/sda
Physical volume "/dev/sda" successfully created
[1] raw/~ # pvs -o pv_name,pe_start
PV 1st PE
/dev/sda 12.00m
[1] raw/~ # pvcreate --dataalignment 8m --dataalignmentoffset 4m
--metadatacopies 0 /dev/sda
Physical volume "/dev/sda" successfully created
[1] raw/~ # pvs -o pv_name,pe_start
PV 1st PE
/dev/sda 8.00m
After this patch:
[1] raw/~ # pvcreate --dataalignment 8m --dataalignmentoffset 4m
--metadatacopies 1 /dev/sda
Physical volume "/dev/sda" successfully created
[1] raw/~ # pvs -o pv_name,pe_start
PV 1st PE
/dev/sda 12.00m
[1] raw/~ # pvcreate --dataalignment 8m --dataalignmentoffset 4m
--metadatacopies 0 /dev/sda
Physical volume "/dev/sda" successfully created
[1] raw/~ # pvs -o pv_name,pe_start
PV 1st PE
/dev/sda 12.00m
Also, remove a superfluous condition "pv->pe_start < pv->pe_align" in:
if (pe_start == PV_PE_START_CALC && pv->pe_start < pv->pe_align)
pv->pe_start = pv->pe_align ...
This part of the condition is not reachable as with the PV_PE_START_CALC,
we always have pv->pe_start set to 0 from the PV struct initialisation
(...the pv->pe_start value is just being calculated).
When a device fails, we may wish to replace those segments with an
error segment. (Like when a 'vgreduce --removemissing' removes a
failed device that happens to be a RAID image/meta.) We are then left
with images that we will eventually want to remove or replace.
This patch allows us to pull out these virtual "error" sub-LVs. This
allows a user to 'lvconvert -m -1 vg/lv' to extract the bad sub-LVs.
Sub-LVs with error segments are considered for extraction before other
possible devices so that good devices are not accidentally removed.
This patch also adds the ability to replace RAID images that contain error
segments. The user will still be unable to run 'lvconvert --replace'
because there is no way to address the 'error' segment (i.e. no PV
that it is associated with). However, 'lvconvert --repair' can be
used to replace the image's error segment with a new PV. This is also
the most appropriate way to do it, since the LV will continue to be
reported as 'partial'.
Currently it is impossible to remove a failed PV which has a RAID LV
on it. This patch fixes the issue by replacing the failed PV with an
'error' segment within the affected sub-LVs. Once there is no longer
a RAID LV using the PV, it can be removed.
Most often, it is better to replace a failed RAID device with a spare.
(You can use 'lvconvert --repair <vg>/<LV>' to accomplish that.)
However, if there are no spares in the volume group and none will be
added, it is useful to be able to removed the failed device.
Following patches address the ability to perform 'lvconvert' operations
on RAID LVs that contain sub-LVs composed of 'error' segments.
We have been using 'mirror_region_size' in lvm.conf as the default region
size for RAID logical volumes as well as mirror logical volumes. Since,
"raid" is more inclusive and representative than "mirror", I have changed
the name of this setting. We must still check for the old setting and warn
the user if we are overriding it with the new setting if both happen to be
present.
This internal function check for active pool device.
For cluster it checks every thin volume,
On the non-clustered VG we need to check just
for presence of -tpool device.
There are currently a few issues with the reporting done on RAID LVs and
sub-LVs. The most concerning is that 'lvs' does not always report the
correct failure status of individual RAID sub-LVs (devices). This can
occur when a device fails and is restored after the failure has been
detected by the kernel. In this case, 'lvs' would report all devices are
fine because it can read the labels on each device just fine.
Example:
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 100.00 lv_rimage_0(0),lv_rimage_1(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
However, 'dmsetup status' on the device tells us a different story:
[root@bp-01 lvm2]# dmsetup status vg-lv
0 1024000 raid raid1 2 DA 1024000/1024000
In this case, we must also be sure to check the RAID LVs kernel status
in order to get the proper information. Here is an example of the correct
output that is displayed after this patch is applied:
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-p 100.00 lv_rimage_0(0),lv_rimage_1(0)
[lv_rimage_0] vg iwi-aor-p /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rmeta_0] vg ewi-aor-p /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
The other case where 'lvs' gives incomplete or improper output is when a
device is replaced or added to a RAID LV. It should display that the RAID
LV is in the process of sync'ing and that the new device is the only one
that is not-in-sync - as indicated by a leading 'I' in the Attr column.
(Remember that 'i' indicates an (i)mage that is in-sync and 'I' indicates
an (I)mage that is not in sync.) Here's an example of the old incorrect
behaviour:
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 100.00 lv_rimage_0(0),lv_rimage_1(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
[root@bp-01 lvm2]# lvconvert -m +1 vg/lv; lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 0.00 lv_rimage_0(0),lv_rimage_1(0),lv_rimage_2(0)
[lv_rimage_0] vg Iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg Iwi-aor-- /dev/sdb1(1)
[lv_rimage_2] vg Iwi-aor-- /dev/sdc1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
[lv_rmeta_2] vg ewi-aor-- /dev/sdc1(0) ** Note that all the images currently are marked as 'I' even though it is
only the last device that has been added that should be marked.
Here is an example of the correct output after this patch is applied:
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 100.00 lv_rimage_0(0),lv_rimage_1(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
[root@bp-01 lvm2]# lvconvert -m +1 vg/lv; lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 0.00 lv_rimage_0(0),lv_rimage_1(0),lv_rimage_2(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rimage_2] vg Iwi-aor-- /dev/sdc1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
[lv_rmeta_2] vg ewi-aor-- /dev/sdc1(0)
** Note only the last image is marked with an 'I'. This is correct and we can
tell that it isn't the whole array that is sync'ing, but just the new
device.
It also works under snapshots...
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg owi-a-r-p 33.47 lv_rimage_0(0),lv_rimage_1(0),lv_rimage_2(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg Iwi-aor-p /dev/sdb1(1)
[lv_rimage_2] vg Iwi-aor-- /dev/sdc1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-p /dev/sdb1(0)
[lv_rmeta_2] vg ewi-aor-- /dev/sdc1(0)
snap vg swi-a-s-- /dev/sda1(51201)
fmt1 doesn't have a separate commit function: updates take effect
immediately vg_write is called, so we must update lvmetad at this
point if we're going to go on and ask lvmetad for the VG metadata
again before calling the commit function (though that's probably an
unsupported and pointless thing to do anyway as the client must
already have that data and it cannot have changed because it's locked
and with devs suspended we shouldn't be communicating with lvmetad;
so when that's fixed properly, this fix here can be reverted).
This problem showed up as an internal error when lvremoving an LVM1
snapshot.
> Internal error: LV snap1 (00000000000000000000000000000001) missing from preload metadata
https://bugzilla.redhat.com/891855
If a RAID array is not in-sync, replacing devices should not be allowed
as a general rule. This is because the contents used to populate the
incoming device may be undefined because the devices being read where
not in-sync. The kernel enforces this rule unless overridden by not
allowing the creation of an array that is not in-sync and includes a
devices that needs to be rebuilt.
Since we cannot know the sync state of an LV if it is inactive, we must
also enforce the rule that an array must be active to replace devices.
That leaves us with the following conditions:
1) never allow replacement or repair of devices if the LV is in-active
2) never allow replacement if the LV is not in-sync
3) allow repair if the LV is not in-sync, but warn that contents may
not be recoverable.
In the case where a user is performing the repair on the command line via
'lvconvert --repair', the warning is printed before the user is prompted
if they would like to replace the device(s). If the repair is automated
(i.e. via dmeventd and policy is "allocate"), then the device is replaced
if possible and the warning is printed.
If the lvmcache_info_from_pvid() fails to find valid
info, invoke the lookup by dev, and only in this case
call lvmcache_info_from_pvid() again.
Also check for the result of info and return
error directly, so the NULL is not passed
to lvmcache_get_label().
Commit bf2741376d started to use
lv_is_active() instead of call for lv_info & info.exists so
we cover also cluster activated devices.
For snapshost the conversion was not correct and introduced
regression by blocking creation of snapshot of inactive LV.
Fix it by assigning lv_is_active() directly.
Note: we still have minor issue to fix - to make
lv_is_???? function able to return error states since
lv_info() may fail.
Target tells us its version, and we may allow different set of options
to be supported with different version of driver.
Idea is to provide individual feature flags and later be
able to query for them.
The 'copy_percent' function takes the 'extents_copied' field from each
segment in an LV to create the numerator for the ratio that is to
become the copy_percent. (Otherwise known as the 'sync' percent for
non-pvmove uses, like mirror LVs and RAID LVs.) This function safely
works on RAID - not just mirrors - so it is better to have it in
lv_manip.c rather than mirror.c.
There's a lot of different functions that do a lot of different things
in lv_manip.c, so I placed the function near a function in lv_manip.c
that it was close to in metadata-exported.h. Different placement in the
file or a different name for the function may be useful.
Use log_warn to print non-fatal warning messages.
Use of log_error would confuse checker for testing
whether proper error has been reported for some real error.
A message is printed when the region_size of a RAID LV is adjusted
to allow for large (> ~1TB) LVs. The message wasn't very clear.
Hopefully, this is better.