IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Refactor the recent metadata-reading optimisation patches.
Remove the recently-added cache fields from struct labeller
and struct format_instance.
Instead, introduce struct lvmcache_vgsummary to wrap the VG information
that lvmcache holds and add the metadata size and checksum to it.
Allow this VG summary information to be looked up by metadata size +
checksum. Adjust the debug log messages to make it clear when this
shortcut has been successful.
(This changes the optimisation slightly, and might be extendable
further.)
Add struct cached_vg_fmtdata to format-specific vg_read calls to
preserve state alongside the VG across separate calls and indicate
if the details supplied match, avoiding the need to read and
process the VG metadata again.
When reading VG mda from multiple PVs - do all the validation only
when mda is seen for the first time and when mda checksum and length
is same just return already existing VG pointer.
(i.e. using 300PVs for a VG would lead to create and destroy 300 config trees....)
If configuration setting is marked in config_setting.h with CFG_DISABLED
flag, default value is always used for such setting, no matter if it's defined
by user (in --config/lvm.conf/lvmlocal.conf).
A warning message is displayed if this happens:
For example:
[1] f21/~ # lvm dumpconfig --validate
WARNING: Configuration setting global/system_id_source is disabled. Using default value.
LVM configuration valid.
[1] f21/~ # pvs
WARNING: Configuration setting global/system_id_source is disabled. Using default value.
PV VG Fmt Attr PSize PFree
/dev/sdb lvm2 --- 128.00m 128.00m
...
Allow cmd->unknown_system_id to be cleared during toolcontext
refresh.
Set a default value of "none" for global/system_id_source.
Allow local/system_id to be empty so it's not impossible for
a later config file to remove it.
In 2.02.99, _init_tags() inadvertently began to ignore the
dm_config_tree struct passed to it. "tags" sections are not
merged together, so the "tags" section in the main config file was
being processed repeatedly and other "tags" sections were ignored.
Just like MD filtering that detects components of software RAID (md),
add detection for firmware RAID.
We're not adding any native code to detect this - there are lots of
firmware RAIDs out there which is just out of LVM scope. However,
with current changes with which we're able to get device info from
external sources (e.g. external_device_info_source="udev"), we can
do this easily if the external device status source has this kind
of information - which is the case of "udev" source where the results
of blkid scans are stored.
This detection should cover all firmware RAIDs that blkid can detect and
which are identified as:
ID_FS_TYPE = {adaptec,ddf,hpt45x,hpt37x,isw,jmicron,lsi_mega,nvidia,promise_fasttrack,silicon_medley,via}_raid_member
For example, with dmeventd/executable set to "" which is not allowed for
this setting, the config validation now ends up with:
$ lvm dumpconfig --validate
Configuration setting "dmeventd/executable" invalid. It cannot be set to an empty value.
LVM configuration invalid.
This check for empty values for string config settings was not
done before (we only checked empty arrays, but not scalar strings).
Support error_if_no_space feature for thin pools.
Report more info about thinpool status:
(out_of_data (D), metadata_read_only (M), failed (F) also as health
attribute.)
Do not use 'any' policy name as a value in config tree - so we stick
with 'policy_settings' and extra 'policy_name' for libdm params.
Update lvm2 API as well.
Example of supported metadata:
policy = "mq"
policy_settings {
migration_threshold = 2048
sequential_threshold = 512
random_threshold = 4
read_promote_adjustment = 10
}
Support compile type configurable defaults for creation
of sparse volumes.
By default now create 'thin-pools' for sparse volumes.
Use the global/sparse_segtype_default to switch back to old
snapshots if needed.
Apply the same compile logic for newly introduces mirror/raid1 options.
The cache mode of a new cache pool is always explicitly
included in the vg metadata. If a cache mode is not
specified on the command line, the cache mode is taken
from lvm.conf allocation/cache_pool_cachemode, which
defaults to "writethrough".
The cache mode can be displayed with lvs -o+cachemode.
Coverity noticed this function may return untouched buffer,
however in this state can't really happen, but anyway
ensure on error path the buffer will have zero lenght string.
Fix get_pool_params to only read params.
Add poolmetadataspare option to get_pool_params.
Move all profile code into update_pool_params.
Move recalculate code into pool_manip.c
Currently, we have two modes of activation, an unnamed nominal mode
(which I will refer to as "complete") and "partial" mode. The
"complete" mode requires that a volume group be 'complete' - that
is, no missing PVs. If there are any missing PVs, no affected LVs
are allowed to activate - even RAID LVs which might be able to
tolerate a failure. The "partial" mode allows anything to be
activated (or at least attempted). If a non-redundant LV is
missing a portion of its addressable space due to a device failure,
it will be replaced with an error target. RAID LVs will either
activate or fail to activate depending on how badly their
redundancy is compromised.
This patch adds a third option, "degraded" mode. This mode can
be selected via the '--activationmode {complete|degraded|partial}'
option to lvchange/vgchange. It can also be set in lvm.conf.
The "degraded" activation mode allows RAID LVs with a sufficient
level of redundancy to activate (e.g. a RAID5 LV with one device
failure, a RAID6 with two device failures, or RAID1 with n-1
failures). RAID LVs with too many device failures are not allowed
to activate - nor are any non-redundant LVs that may have been
affected. This patch also makes the "degraded" mode the default
activation mode.
The degraded activation mode does not yet work in a cluster. A
new cluster lock flag (LCK_DEGRADED_MODE) will need to be created
to make that work. Currently, there is limited space for this
extra flag and I am looking for possible solutions. One possible
solution is to usurp LCK_CONVERT, as it is not used. When the
locking_type is 3, the degraded mode flag simply gets dropped and
the old ("complete") behavior is exhibited.
The --binary option, if used, causes all the binary values reported
in reporting commands to be displayed as "0" or "1" instead of descriptive
literal values (value "unknown" is still used for values that could not be
determined).
Also, add report/binary_values_as_numeric lvm.conf option with the same
functionality as the --binary option (the --binary option prevails
if both --binary cmd option and report/binary_values_as_numeric lvm.conf
option is used at the same time). The report/binary_values_as_numeric is
also profilable.
This makes it easier to use and check lvm reporting command output in scripts.
The dumpconfig now understands --commandprofile/--profile/--metadataprofile
The --commandprofile and --profile functionality is almost the same
with only one difference and that is that the --profile is just used
for dumping the content, it's not applied for the command itself
(while the --commandprofile profile is applied like it is done for
any other LVM command).
We also allow --metadataprofile for dumpconfig - dumpconfig *does not*
touch VG/LV and metadata in any way so it's OK to use it here (just for
dumping the content, checking the profile validity etc.).
The validity of the profile can be checked with:
dumpconfig --commandprofile/--profile/--metadataprofile --validate
...depending on the profile type.
Also, mention --config in the dumpconfig help string so users know
that dumpconfig handles this too (it did even before, but it was not
documented in the help string).
- When defining configuration source, the code now uses separate
CONFIG_PROFILE_COMMAND and CONFIG_PROFILE_METADATA markers
(before, it was just CONFIG_PROFILE that did not make the
difference between the two). This helps when checking the
configuration if it contains correct set of options which
are all in either command-profilable or metadata-profilable
group without mixing these groups together - so it's a firm
distinction. The "command profile" can't contain
"metadata profile" and vice versa! This is strictly checked
and if the settings are mixed, such profile is rejected and
it's not used. So in the end, the CONFIG_PROFILE_COMMAND
set of options and CONFIG_PROFILE_METADATA are mutually exclusive
sets.
- Marking configuration with one or the other marker will also
determine the way these configuration sources are positioned
in the configuration cascade which is now:
CONFIG_STRING -> CONFIG_PROFILE_COMMAND -> CONFIG_PROFILE_METADATA -> CONFIG_FILE/CONFIG_MERGED_FILES
- Marking configuration with one or the other marker will also make
it possible to issue a command context refresh (will be probably
a part of a future patch) if needed for settings in global profile
set. For settings in metadata profile set this is impossible since
we can't refresh cmd context in the middle of reading VG/LV metadata
and for each VG/LV separately because each VG/LV can have a different
metadata profile assinged and it's not possible to change these
settings at this level.
- When command profile is incorrect, it's rejected *and also* the
command exits immediately - the profile *must* be correct for the
command that was run with a profile to be executed. Before this
patch, when the profile was found incorrect, there was just the
warning message and the command continued without profile applied.
But it's more correct to exit immediately in this case.
- When metadata profile is incorrect, we reject it during command
runtime (as we know the profile name from metadata and not early
from command line as it is in case of command profiles) and we
*do continue* with the command as we're in the middle of operation.
Also, the metadata profile is applied directly and on the fly on
find_config_tree_* fn call and even if the metadata profile is
found incorrect, we still need to return the non-profiled value
as found in the other configuration provided or default value.
To exit immediately even in this case, we'd need to refactor
existing find_config_tree_* fns so they can return error. Currently,
these fns return only config values (which end up with default
values in the end if the config is not found).
- To check the profile validity before use to be sure it's correct,
one can use :
lvm dumpconfig --commandprofile/--metadataprofile ProfileName --validate
(the --commandprofile/--metadataprofile for dumpconfig will come
as part of the subsequent patch)
- This patch also adds a reference to --commandprofile and
--metadataprofile in the cmd help string (which was missing before
for the --profile for some commands). We do not mention --profile
now as people should use --commandprofile or --metadataprofile
directly. However, the --profile is still supported for backward
compatibility and it's translated as:
--profile == --metadataprofile for lvcreate, vgcreate, lvchange and vgchange
(as these commands are able to attach profile to metadata)
--profile == --commandprofile for all the other commands
(--metadataprofile is not allowed there as it makes no sense)
- This patch also contains some cleanups to make the code handling
the profiles more readable...
Mark profilable settings with a separate CFG_PROFILABLE_METADATA
flag where the profile can be attached to VG/LV. This makes it possible
to differentiate global command-profilable settings (CFG_PROFILABLE flag)
and contextual metadata-profilable (per VG/LV) settings (CFG_PROFILABLE_METADATA flag).
When cmd refresh is called, we need to move any already loaded profiles
to profiles_to_load list which will cause their reload on subsequent
use. In addition to that, we need to take into account any change
in config/profile configuration setting on cmd context refresh
since this setting could be overriden with --config.
Also, when running commands in the shell, we need to remove the
global profile used from the configuration cascade so the profile
is not incorrectly reused next time when the --profile option is
not specified anymore for the next command in the shell.
This bug only affected profile specified by --profile cmd line
arg, not profiles referenced from LVM metadata.
Before, the cft_check_handle used to direct configuration checking
was part of cmd_context. It's better to attach this as part of the
exact config tree against which the check is done. This patch moves
the cft_check_handle out of cmd_context and it attaches it to the
config tree directly as dm_config_tree->custom->config_source->check_handle.
This change makes it easier to track the config tree check results
and provides less space for bugs as the results are directly attached
to the tree and we don't need to be cautious whether the global value
is correct or not (and whether it needs reinitialization) as it was
in the case when the cft_check_handle was part of cmd_context.
Add CONFIG_FILE_SPECIAL config source id to make a difference between
real configuration tree (like lvm.conf and tag configs) and special purpose
configuration tree (like LVM metadata, persistent filter).
This makes it easier to attach correct customized data to the config
tree that is created out of the source then.
ignore_suspended_devices=0 is already used in lvm.conf we distribute,
but it was still "1" in the code (so it was used when lvm.conf value
was not defined). It should be "0" too.
Before:
thin_disabled_features = ""
Now:
thin_disabled_features = []
Which is a more correct and consistent way of specifying void array
though parses can handle both forms.