If the activation step in lvcreate fails (e.g. the specified
minor number is already used), then the lvcreate is reverted,
but the LV lock in lvmlockd was not being unlocked or properly
freed.
With commit 41c10034aa we actually
do require LV to be used with _vg_write_lv_suspend_commit_backup().
So write a proper separte single wrapper for write && commit && backup.
Since we discovered status reporting from 'md' goes from large set
of weird states we can't just decided based on this word.
So let it pass for rebuild and idle as well
and check for health devices afterwards.
When raid leg rimage device is marked as 'D'ead by mdcore,
lvm2 was not able to replace such device with allocate policy,
as device has not appared as missing.
Add detection of transiently failing devices.
Basically reverting commit 58a9f88b8c.
We can use origin_only in case we are snapshot's origin,
as we do support this stack.
So when we are 'uncaching' origin+snaps - we do need to reload only
origin and we do not need to play with snaps.
Handle change of 'region size' better and follow also standard rule
if the command can't success (i.e. size is already same) we return
error for all such cases.
Also log_pring more info about adjusted value (just like we
do for rounding)
Also avoid keep pointers on 'display_*' values - they are in
ringbuffer for immediate use - not to be kept across multiple calls
(as they could be already overwritten by later calls) - so dropped
seg_region_size_str
Since cache LV can be a stacked device, there is no real reason
trying to use slight optimised tree for origin_only cache reload
(it could be even wrongly implemented in this case).
We can easily go with stardard tree load here.
When user runs command like 'lvconvert --splitcache' the operation
might be actually either slow or not making any progress in kernel,
so lets give user a chance to abort such operation.
When user press 'Ctrl+C' device table is restored to pre-flushing state.
Remove explicit activation of SubLVs and let lv_update_and_reload()
perform the proper (pre-)loading sequencing of tables.
This avoids related callback functions which are removed.
Related: rhbz1448116
Related: rhbz1461526
Related: rhbz1448123
When lock-holding LV differs from actually request locked LV,
we drop origin_only flag as it has no use - it'd be applied
on completely different LV.
Example of problem:
Raid is thin-pool _tdata LV.
Raid run origin_only locking on stacked device.
As lock holder is discovered thinLV.
Whole origin_only operation is then applied only on thinLV
changing the meaning of whole operation.
NOTE: this patch does not change anything for LV that are
already top-level lock holding LVs (i.e. thinLVs, snahoshots/origins).
Disable until we have a proper fix for reshape space allocation,
switching it to begin/end of rimages and activation in the cluster.
Related: rhbz1448116
Related: rhbz1461526
Related: rhbz1448123
Enhance reporting code, so it does not need to do 'extra' ioctl to
get 'status' of normal raid and provide percentage directly.
When we have 'merging' snapshot into raid origin, we still need to get
this secondary number with extra status call - however, since 'raid'
is always a single segment LV - we may skip 'copy_percent' call as
we directly know the percent and also with better precision.
NOTE: for mirror we still base reported number on the percetage of
transferred extents which might get quite imprecisse if big size
of extent is used while volume itself is smaller as reporting jump
steps are much bigger the actual reported number provides.
2nd.NOTE: raid lvs line report already requires quite a few extra status
calls for the same device - but fix will be need slight code improval.
For the test clean-up, I was providing too many devices to the first
command - possibly allowing it to allocate in the wrong place. I was
also not providing a device for the second command - virtually ensuring
the test was not performing correctly at times.
This patch ensures that under normal conditions (i.e. not during repair
operations) that users are prevented from removing devices that would
cause data loss.
When a RAID1 is undergoing its initial sync, it is ok to remove all but
one of the images because they have all existed since creation and
contain all the data written since the array was created. OTOH, if the
RAID1 was created as a result of an up-convert from linear, it is very
important not to let the user remove the primary image (the source of
all the data). They should be allowed to remove any devices they want
and as many as they want as long as one original (primary) device is left
during a "recover" (aka up-convert).
This fixes bug 1461187 and includes the necessary regression tests.