If the fabric is broken instantly, the drives connected on the fabric
will disappear from the system. For worst case, the lease is timeout
and the drives cannot recovery back. So a new test is added to emulate
this scenario, it uses a drive for LVM operations and this drive is also
used for locking scheme; if the drive and all its associated paths (if
the drive supports multiple paths) are disconnected, the lock manager
should stop the lockspace for the VG/LVs.
And afterwards, if the drive recovers back, the VG/LV resident in the
drive should be operated properly. The test command is as below:
# make check_lvmlockd_idm \
LVM_TEST_BACKING_DEVICE=/dev/sdp3 LVM_TEST_FAILURE=1 \
T=idm_fabric_failure_timeout.sh
Signed-off-by: Leo Yan <leo.yan@linaro.org>