We need both offset and length when trying to wipe detected signatures.
The libblkid can fail so it's good to have an error message issued for
this state instead of being silent (libblkid does not issue any error
messages here). We just issued "stack" here before but that was not
quite useful if some error occurs...
If there is no define for BLKPBSZGET - we have hard time how to
decrypt physical block size - we can't use here block_size,
since this is usually 4k while we need to use 512b.
FIXME: find some better way, until that enforce value 512.
Eventually we could also try to put in:
+#ifndef BLKPBSZGET
+# define BLKPBSZGET _IO(0x12,123)
+#endif
but this will still not work well on old kernels.
When the device is inserted in dev_name_confirmed() stat() is
called twice as _insert() has it's own stat() call.
Extend _insert() parameter with struct stat* - which could be used
if it has been just obtained. When NULL is passed code is
doing its own stat() call as before.
If we're calling pvcreate on a device that already has a PV label,
the blkid detects the existing PV and then we consider it for wiping
before we continue creating the new PV label and we issue a warning
with a prompt whether such old PV label should be removed. We don't
do this with native signature detection code. Let's make it consistent
with old behaviour.
But still keep this "PV" (identified as "LVM1_member" or "LVM2_member"
by blkid) detection when creating new LVs to avoid unexpected PV label
appeareance inside LV.
This is actually the wipefs functionailty as a matter of fact
(wipefs uses the same libblkid calls).
libblkid is more rich when it comes to detecting various
signatures, including filesystems and users can better
decide what to erase and what should be kept.
The code is shared for both pvcreate (where wiping is necessary
to complete the pvcreate operation) and lvcreate where it's up
to the user to decide.
The verbose output contains a bit more information about the
signature like LABEL and UUID.
For example:
raw/~ # lvcreate -L16m vg
WARNING: linux_raid_member signature detected on /dev/vg/lvol0 at offset 4096. Wipe it? [y/n]
or more verbose one:
raw/~ # lvcreate -L16m vg -v
...
Found existing signature on /dev/vg/lvol0 at offset 4096: LABEL="raw.virt:0" UUID="da6af139-8403-5d06-b8c4-13f6f24b73b1" TYPE="linux_raid_member" USAGE="raid"
WARNING: linux_raid_member signature detected on /dev/vg/lvol0 at offset 4096. Wipe it? [y/n]
The verbose output is the same output as found in blkid.
The wipe_known_signatures fn now wraps the _wipe_signature fn that is called
for each known signature (currently md, swap and luks). This patch makes the
code more readable, not repeating the same sequence when used anywhere in the
code. We're going to reuse this code later...
Put common printf() case into a function and use
the string with text format as direct arg to make
the compile time validation of args easier and
code shorter.
Switch log_error() to log_warn(), since 'return 0'
doesn't cause any failure here.
Split out the partitioned device filter that needs to open the device
and move the multipath filter in front of it.
When a device is multipathed, sending I/O to the underlying paths may
cause problems, the most obvious being I/O errors visible to lvm if a
path is down.
Revert the incorrect <backtrace> messages added when a device doesn't
pass a filter.
Log each filter initialisation to show sequence.
Avoid duplicate 'Using $device' debug messages.
The dev_get_primary_dev fn now returns:
0 if the dev is already a primary dev
1 if the dev is a partition, primary dev is returned in "result" (output arg)
-1 on error
This way, we can better differentiate between the error state
and the state in which the dev supplied is not a partition
in the caller (this was same return value before).
Also, if we already have information about the device type,
we can check its major number against the list of known device
types (cmd->dev_types) directly, so we don't need to go through
the sysfs - we only check the major:minor pair which is a bit
more straightforward and faster. If the dev_types does not have
any info about this device type, the code just fallbacks to
the original sysfs interface to get the partition info.
Changes:
- move device type registration out of "type filter" (filter.c)
to a separate and new dev-type.[ch] for common use throughout the code
- the structure for keeping the major numbers detected for available
device types and available partitioning available is stored in
"dev_types" structure now
- move common partitioning detection code to dev-type.[ch] as well
together with other device-related functions bound to dev_types
(see dev-type.h for the interface)
The dev-type interface contains all common functions used to detect
subsystems/device types, signature/superblock recognition code,
type-specific device properties and other common device properties
(bound to dev_types), including partitioning support.
- add dev_types instance to cmd context as cmd->dev_types for common use
- use cmd->dev_types throughout as a central point for providing
information about device types
Last commit made dump filter only partially composable.
Add remaining functionality and also support composable wipe,
which is needed, when i.e. vgscan needs to remove cache.
(in release fix)
Add a generic dump operation to filters and make the composite filter call
through to its components. Previously, when global filter was set, the code
would treat the toplevel composite filter's private area as if it belonged a
persistent filter, trying to write nonsense into a non-sensical file.
Also deal with NULL cmd->filter gracefully.
For example, the old call and reference:
find_config_tree_str(cmd, "devices/dir", DEFAULT_DEV_DIR)
...now becomes:
find_config_tree_str(cmd, devices_dir_CFG)
So we're referring to the named configuration ID instead
of passing the configuration path and the default value
is taken from central config definition in config_settings.h
automatically.
Use log_warn to print non-fatal warning messages.
Use of log_error would confuse checker for testing
whether proper error has been reported for some real error.
There's no need to have the device open RW while obtaining the readahead value.
The RW open used before caused the CHANGE udev event to be generated if the
WATCH udev rule was set for the underlying device (and that is normally the
case both for non-dm and dm devices by default).
This did not cause any problems before since we were not interested in
*underlying* devices. However, with upcoming changes (autoactivation), we're
watching for events on underlying devices marked as PVs and such a spurious
event could cause the autoactivation code to be triggered. So when trying
to deactivate the volume, we could end up with immediate activation just after
that because of the CHANGE event originated in the WATCH udev rule since the
underlying device was open RW during the deactivation process.
Though maybe a better solution would be to completely filter such spurious
events out of the autoactivation process somehow, it's still useful if there
are as least spurious events generated as possible in the system itself.
Libudev does not provide transactions when querying udev database - once we
get the list of block devices (devices/obtain_device_list_from_udev=1) and
we iterate over the list to get more detailed information about device node
and symlink names used etc., the device could be removed just in between we
get the list and put a query for more info. In this case, libudev returns
NULL value as the device does not exist anymore.
Recently, we've added a warning message to reveal such situations. However,
this could be misleading if the device is not related to the LVM action
we're just processing - the non-related block device could be removed in
parallel and this is not an error but a possible and normal operation.
(N.B. This "missing info" should not happen when devices are related to
the LVM action we're just processing since all such processing should be
synchronized with udev and the udev db must always be in consistent state
after the sync point. But we can't filter this situation out from others,
non-related devices, so we have to lower the message verbosity here for a
general solution.)