IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Add to commits 87117c2b25 and 0b8bf73a63 to avoid refreshing two
times altogether, thus avoiding issues related to clustered, remotely
activated RaidLV. Avoid need to repeat "lvchange --refresh RaidLV"
two times as a workaround to refresh a RaidLV. Fix handles removal
of temporary *-missing-* devices created for any missing segments
in RAID SubLVs during activation.
Because the kernel dm-raid target isn't able to handle transiently
failing devices properly we need
"[dm-devel][PATCH] dm raid: fix transient device failure processing"
as well.
test: add lvchange-raid-transient-failures.sh
and enhance lvconvert-raid.sh
Resolves: rhbz1025322
Related: rhbz1265191
Related: rhbz1399844
Related: rhbz1404425
Introduce LVM_TEST_LVMETAD_DEBUG_OPTS to allow to override
default debug opts for lvmetad.
However could be still overloaded on command line:
make check_lvmetad LVM_TEST_LVMETAD_DEBUG_OPTS="-l all"...
When raid leg is extracted, now the preload code handles this state
correctly and put proper new table entry into dm tree,
so the activation of extracted leg and removed metadata works
after commit.
When we split leg from raid - we take a proper new lock for a new LV.
However for now activation checks only 'existince' of device UUID,
but it's not validating device has a proper name.
As a quick fix call suspend()/resume() to rename after split mirror.
Commit 33d69162e4 reduced the number of
PVs to a level where the test could not function. (It is impossible
to replace 3 PVs of a 4-way RAID1 LV if there are only 5 PVs.)
I've changed build_parallel_areas_from_lv to take a new parameter
that allows the caller to build parallel areas by LV vs by segment.
Previously, the function created a list of parallel areas for each
segment in the given LV. When it came time for allocation, the
parallel areas were honored on a segment basis. This was problematic
for RAID because any new RAID image must avoid being placed on any
PVs used by other images in the RAID. For example, if we have a
linear LV that has half its space on one PV and half on another, we
do not want an up-convert to use either of those PVs. It should
especially not wind up with the following, where the first portion
of one LV is paired up with the second portion of the other:
------PV1------- ------PV2-------
[ 2of2 image_1 ] [ 1of2 image_1 ]
[ 1of2 image_0 ] [ 2of2 image_0 ]
---------------- ----------------
Previously, it was possible for this to happen. The change makes
it so that the returned parallel areas list contains one "super"
segment (seg_pvs) with a list of all the PVs from every actual
segment in the given LV and covering the entire logical extent range.
This change allows RAID conversions to function properly when there
are existing images that contain multiple segments that span more
than one PV.
If a RAID LV has images that are spread across more than one PV
and you allocate a new image that requires more than one PV,
parallel_areas is only honored for one segment. This commit
adds a test for this condition.
3.12.0 kernel prevents raid test to be usable,
leaving unremovable devices in table.
This needs to be fixed ASAP, meanwhile disable test to make
test machines at least usable.
1) When converting from an x-way mirror/raid1 to a y-way mirror/raid1,
the default behaviour should be to stay the same segment type.
2) When converting from linear to mirror or raid1, the default behaviour
should honor the mirror_segtype_default.
3) When converting and the '--type' argument is specified, the '--type'
argument should be honored.
catch such conditions, but errors in the tests caused the issue to go
unnoticed. The code has been fixed to perform #2 properly, the tests
have been corrected to properly test for #2, and a few other tests
were changed to explicitly specify the '--type mirror' when necessary.
A know issue with kmem_cach is causing failures while testing
RAID 4/5/6 device replacement. Blacklist the offending kernel
so that these tests are not performed there.
Creation, deletion, [de]activation, repair, conversion, scrubbing
and changing operations are all now available for RAID LVs in a
cluster - provided that they are activated exclusively.
The code has been changed to ensure that no LV or sub-LV activation
is attempted cluster-wide. This includes the often overlooked
operations of activating metadata areas for the brief time it takes
to clear them. Additionally, some 'resume_lv' operations were
replaced with 'activate_lv_excl_local' when sub-LVs were promoted
to top-level LVs for removal, clearing or extraction. This was
necessary because it forces the appropriate renaming actions the
occur via resume in the single-machine case, but won't happen in
a cluster due to the necessity of acquiring a lock first.
The *raid* tests have been updated to allow testing in a cluster.
For the most part, this meant creating devices with '-aey' if they
were to be converted to RAID. (RAID requires the converting LV to
be EX because it is a condition of activation for the RAID LV in
a cluster.)
If the user would upconvert a linear LV to a mirror without specifying
the segment type ("--type mirror" vs "--type raid1"), the "mirror"
segment type would be chosen without consulting the 'default_mirror_segtype'
setting in lvm.conf. This is now used as the basis for determining
which should be used if left unspecified.
I'm not sure what 'BUG's were being encountered when the restriction
to limit lvconvert-raid.sh tests to kernels > 3.2 was added. I do know
that there were BUG's that could be triggered when testing snapshots and
some of the earliest DM RAID available in the kernel. I've taken out
the 3.2 kernel restriction and added a dm-raid >= 1.2 restriction instead.
This will allow the test to run on patched production kernels.
Separate original raid test and new raid10 test,
so the old could be tested on platforms without raid10 support.
Replace test-unfriendly `ls /dev/mapper` with dmsetup ls
When reformatting the 'lvchange_resync' code in commit
05131f5853, a '!' should have been removed
from the condition that checks for the LV_NOTSYNCED flag on a corelog
mirror LV. The presence of this '!' caused the LV_NOTSYNCED flag to be
cleared when it wasn't present and left when it was present.
It is not allowed to add images to a 'mirror' or 'raid1' LV if the
LV_NOTSYNCED flag is set. We add some up-convert tests to ensure this
behavior is being enforced and that the LV_NOTSYNCED flag is being
properly cleared by 'lvchange --resync'.
(Not updating WHATS_NEW because this is intrarelease.)
This patch adds support for RAID10. It is not the default at this
stage. The user needs to specify '--type raid10' if they would like
RAID10 instead of stacked mirror over stripe.
Indent
Shell improvements - use internal function for checks
Use PVs in "" (LV and VG cannot have spaces)
Several test very starting 'dmeventd' without annoucing
it via prepade_dmeventd.
Fix some of test actually.
When down-converting a RAID1 device, it is the last device that is extracted
and removed when the user does not specify a particular device. However,
when a device is specified (and it is not the last), the device is removed and
the remaining sub-LVs are "shifted down" to fill the hole. This cause problems
when resuming the LV because if the shifted devices were resumed (and thus
renamed) before the sub-LV being extracted, there would be a name conflict.
The solution is to resume the extracted sub-LVs first so that they can be
properly renamed preventing a possible conflict.
This addresses bug 801967.
Reduce disc excercise for some test and focus on LVM testing by
using smaller extent size.
Reduce number of teardown_devs calls and use vg/lvremove instead.
Don't sleep for seconds on pvmove.
FIXME: shell/lvconvert-mirror-basic.sh seems to need more checking.
Test fails for smalled extent size then 512k.
Failure to do so results in "Performing unsafe table load while X device(s) are
known to be suspended" errors. While fixing the problem in this way works and
is consistent with the way the mirror segment type does it, it would be nice
to find a solution that uses the generic suspend/resume calls.
Also included in this check-in are additions to the test suite that perform
conversions on RAID LVs under a snapshot. These tests are disabled for the
time being due to a kernel bug that is yet to be tracked down.