IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Instead of using size of 'empty header' in vdopool use fixed size 4K
for a 'wrappeing' vdo-pool device.
This fixes the issue when user tried to activate vdo-pool after
a conversion from vdo managed device with 'vgchange -ay' - where
this command activated all LVs with 'vdo-pool' wrapping device as well,
but this converted pool uses 0-length header.
This 4k size should usually prevent other tools like 'blkid' recognize
such device as anything - so it shouldn't cause any problems with
duplicate indentification of devices.
Introduce struct vdo_pool_size_config usable to calculate necessary
memory size for active VDO volume.
Function lv_vdo_pool_size_config() is able to read out this
configuration out of runtime DM table line.
The new option "--fs String" for lvresize/lvreduce/lvextend
controls the handling of file systems before/after resizing
the LV. --resizefs is the same as --fs resize.
The new option "--fsmode String" can be used to control
mounting and unmounting of the fs during resizing.
Possible --fs values:
checksize
Only applies to reducing size; does nothing for extend.
Check the fs size and reduce the LV if the fs is not using
the affected space, i.e. the fs does not need to be shrunk.
Fail the command without reducing the fs or LV if the fs is
using the affected space.
resize
Resize the fs using the fs-specific resize command.
This may include mounting, unmounting, or running fsck.
See --fsmode to control mounting behavior, and --nofsck to
disable fsck.
resize_fsadm
Use the old method of calling fsadm to handle the fs
(deprecated.) Warning: this option does not prevent lvreduce
from destroying file systems that are unmounted (or mounted
if prompts are skipped.)
ignore
Resize the LV without checking for or handling a file system.
Warning: using ignore when reducing the LV size may destroy the
file system.
Possible --fsmode values:
manage
Mount or unmount the fs as needed to resize the fs,
and attempt to restore the original mount state at the end.
nochange
Do not mount or unmount the fs. If mounting or unmounting
is required to resize the fs, then do not resize the fs or
the LV and fail the command.
offline
Unmount the fs if it is mounted, and resize the fs while it
is unmounted. If mounting is required to resize the fs,
then do not resize the fs or the LV and fail the command.
Notes on lvreduce:
When no --fs or --resizefs option is specified:
. lvextend default behavior is fs ignore.
. lvreduce default behavior is fs checksize
(includes activating the LV.)
With the exception of --fs resize_fsadm|ignore, lvreduce requires
the recent libblkid fields FSLASTBLOCK and FSBLOCKSIZE.
FSLASTBLOCK*FSBLOCKSIZE is the last byte used by the fs on the LV,
which determines if reducing the fs is necessary.
When the volume size is extended, there is no need to flush
IO operations (nothing can be targeting new space yet).
VDO target is supported as target that can safely work with
this condition.
Such support is also needed, when extending VDOPOOL size
while the pool is reaching its capacity - since this allows
to continue working without reaching 'out-of-space' condition
due to flushing of all in flight IO.
dev_name(dev) returns "[unknown]" if there are no names
on dev->aliases. It's meant mainly for log messages.
Many places assume a valid path name is returned, and
use it directly. A caller that wants to use the path
from dev_name() must first check if the dev has any
paths with dm_list_empty(&dev->aliases).
Different target type for LV it's not an internal error.
i.e. when target type is replaced with 'error' type - it should be
reported as regular warning and not cause interruption of command with
internall error.
With very old version of DM target driver we have to avoid
trying to use newuuid setting - otherwise we get error
during ioctl preparation phase.
Patch is fixing regression from commit:
988ea0e94c
Since we check for present DM devices - cache result for
futher use of checking presence of such device.
lvm2 uses cache result for label scan, but also when
it tries to activate or deactivate LV - however only simple
target 'striped' is reasonably supported.
Use disable_dm_devs to be able to control when lv_info()
get cache or uncached results.
TODO: support more type, however this is getting very complicated.
New versions of kvdo module exposes statistics at new location:
/sys/block/dm-XXX/vdo/statistics/...
Enhance lvm2 to access this location first.
Also if the statistic info is missing - make it 'debug' level info,
so it is not failing 'lvs' command.
pvid and vgid are sometimes a null-terminated string, and
other times a 'struct id', and the two types were often
cast between each other. When a struct id was cast to a char
pointer, the resulting string would not necessarily be null
terminated. Casting a null-terminated string id to a
struct id is fine, but is still avoided when possible.
A struct id is: int8_t uuid[ID_LEN]
A string id is: char pvid[ID_LEN + 1]
A convention is introduced to help distinguish them:
- variables and struct fields named "pvid" or "vgid"
should be null-terminated strings.
- variables and struct fields named "pv_id" or "vg_id"
should be struct id's.
- examples:
char pvid[ID_LEN + 1];
char vgid[ID_LEN + 1];
struct id pv_id;
struct id vg_id;
Function names also attempt to follow this convention.
Avoid casting between the two types as much as possible,
with limited exceptions when known to be safe and clearly
commented.
Avoid using variations of strcpy and strcmp, and instead
use memcpy/memcmp with ID_LEN (with similar limited
exceptions possible.)
Devices made only from 'error' target cannot be used,
but if the device is also combined from 'zero' target
the same rule can be applied as such device cannot be used.
Just like with other segtype use this function to get whole
raid status info available per a single ioctl call.
Also it nicely simplifies read of percentage info about
in_sync portion of raid volume.
TODO: drop use of other calls then lv_raid_status call,
since all such calls could already use status - so it just
adds unnecessary duplication.
Reduce ioctl count and avoid separate info check,
when we can get the same info from status ioctl.
When devmanager calls return 0, then the exists value 0
means the reason of failure is missing device in table.
In such case we avoid stack trace.
Swap the flush parameter for the vdo status function
to match thin pool status.
Make the generic "device is not usable" message from filter-usable
more specific in case the device is not usable because it's an LV.
(i.e. when scan_lvs=0)
Initial support for thin-pool used slightly smaller max size 15.81GiB
for thin-pool metadata. However the real limit later settled at 15.88GiB
(difference is ~64MiB - 16448 4K blocks).
lvm2 could not simply increase the size as it has been using hard cropping
of the loaded metadata device to avoid warnings printing warning of kernel
when the size was bigger (i.e. due to bigger extent_size).
This patch adds the new lvm.conf configurable setting:
allocation/thin_pool_crop_metadata
which defaults to 0 -> no crop of metadata beyond 15.81GiB.
Only user with these sizes of metadata will be affected.
Without cropping lvm2 now limits metadata allocation size to 15.88GiB.
Any space beyond is currently not used by thin-pool target.
Even if i.e. bigger LV is used for metadata via lvconvert,
or allocated bigger because of to large extent size.
With cropping enabled (=1) lvm2 preserves the old limitation
15.81GiB and should allow to work in the evironement with
older lvm2 tools (i.e. older distribution).
Thin-pool metadata with size bigger then 15.81G is now using CROP_METADATA
flag within lvm2 metadata, so older lvm2 recognizes an
incompatible thin-pool and cannot activate such pool!
Users should use uncropped version as it is not suffering
from various issues between thin_repair results and allocated
metadata LV as thin_repair limit is 15.88GiB
Users should use cropping only when really needed!
Patch also better handles resize of thin-pool metadata and prevents resize
beoyond usable size 15.88GiB. Resize beyond 15.81GiB automatically
switches pool to no-crop version. Even with existing bigger thin-pool
metadata command 'lvextend -l+1 vg/pool_tmeta' does the change.
Patch gives better controls 'coverted' metadata LV and
reports less confusing message during conversion.
Patch set also moves the code for updating min/max into pool_manip.c
for better sharing with cache_pool code.
When using cache with a cachevol, the cache_check tool was
not being run on the cache metadata during activation.
cache_check clears the needs_check flag in the cache
metadata, so if the flag was set due to an unclean
shutdown, the activation would fail.
Introduce structures lv_status_thin_pool and
lv_status_thin (pair to lv_status_cache, lv_status_vdo)
Convert lv_thin_percent() -> lv_thin_status()
and lv_thin_pool_percent() + lv_thin_pool_transaction_id() ->
lv_thin_pool_status().
This way a function user can see not only percentages, but also
other important status info about thin-pool.
TODO:
This patch tries to not change too many other things,
but pool_below_threshold() now uses new thin-pool info to return
failure if thin-pool cannot be actually modified.
This should be handle separately in a better way.
Since we do not support rimage & rmeta for snapshots - we can
avoid quering for -cow devices and add them as origin_only -
since their snapshots (-cow) could have never existed.
This redumes several ioctl operation during table preloading.
dm-integrity stores checksums of the data written to an
LV, and returns an error if data read from the LV does
not match the previously saved checksum. When used on
raid images, dm-raid will correct the error by reading
the block from another image, and the device user sees
no error. The integrity metadata (checksums) are stored
on an internal LV allocated by lvm for each linear image.
The internal LV is allocated on the same PV as the image.
Create a raid LV with an integrity layer over each
raid image (for raid levels 1,4,5,6,10):
lvcreate --type raidN --raidintegrity y [options]
Add an integrity layer to images of an existing raid LV:
lvconvert --raidintegrity y LV
Remove the integrity layer from images of a raid LV:
lvconvert --raidintegrity n LV
Settings
Use --raidintegritymode journal|bitmap (journal is default)
to configure the method used by dm-integrity to ensure
crash consistency.
Initialization
When integrity is added to an LV, the kernel needs to
initialize the integrity metadata/checksums for all blocks
in the LV. The data corruption checking performed by
dm-integrity will only operate on areas of the LV that
are already initialized. The progress of integrity
initialization is reported by the "syncpercent" LV
reporting field (and under the Cpy%Sync lvs column.)
Example: create a raid1 LV with integrity:
$ lvcreate --type raid1 -m1 --raidintegrity y -n rr -L1G foo
Creating integrity metadata LV rr_rimage_0_imeta with size 12.00 MiB.
Logical volume "rr_rimage_0_imeta" created.
Creating integrity metadata LV rr_rimage_1_imeta with size 12.00 MiB.
Logical volume "rr_rimage_1_imeta" created.
Logical volume "rr" created.
$ lvs -a foo
LV VG Attr LSize Origin Cpy%Sync
rr foo rwi-a-r--- 1.00g 4.93
[rr_rimage_0] foo gwi-aor--- 1.00g [rr_rimage_0_iorig] 41.02
[rr_rimage_0_imeta] foo ewi-ao---- 12.00m
[rr_rimage_0_iorig] foo -wi-ao---- 1.00g
[rr_rimage_1] foo gwi-aor--- 1.00g [rr_rimage_1_iorig] 39.45
[rr_rimage_1_imeta] foo ewi-ao---- 12.00m
[rr_rimage_1_iorig] foo -wi-ao---- 1.00g
[rr_rmeta_0] foo ewi-aor--- 4.00m
[rr_rmeta_1] foo ewi-aor--- 4.00m
When vdopool is activated standalone - we use a wrapping linear device
to hold actual vdo device active - for this we can set-up read-only
device to ensure there cannot be made write through this device to
actual pool device.
Fix the anoying kernel message reported:
device-mapper: cache: 253:2: metadata operation 'dm_cache_commit' failed: error = -5
which has been reported while cachevol has been removed.
Happened via confusing variable - so switch the variable to commonly user '_size'
which presents a value in sector units and avoid 'scaling' this as extent length
by vg extent size when placing 'error' target on removal path.
Patch shouldn't have impact on actual users data, since at this moment
of removal all date should have been already flushed to origin device.
m
Enhance lv_info with lv_info_with_name_check.
This 'variant' not only check existance if UUID in DM table
but also compares its DM name whether it's matching expected LV name.
Otherwise activation may 'skip' activation with rename in case the
DM UUID already exists, just device is different name.
This change make fairly easier manipulation with i.e. detached mirror
leg which ATM is using same UUID - just the LV name have been changed.
Used code was not able to run 'activation' (and do a rename) and just
skipped the call. So the code used to do a workaround and 'tried'
to deactivate such LV firts - this however work only in non-clvmd case,
as cluster was not having the lock for deactivated LV.
With this extended lv_info code will run 'activation' and will
synchronize the name to match expected LV name.
Patch extends _lv_info() with new paramter 'with_name_check',
which is later translated into 'name_check' argument for
_info_run() which in case of name mismatch evaluates the
check as if device does not exists.
Such call is only used in one place _lv_activate() which then
let activation run. All other invocation of _info() calls
are left intact.
TODO: fix mirror table manipulation (and raid)....
When checking device id of a thin device that is just being
merged - the snapshot actually could have been already finished
which means '-real' suffix for the LV is already gone and just LV
is there - so check explicitely for this condition and use
correct UUID for this case.
Since code is using -cdata and -cmeta UUID suffixes, it does not need
any new 'extra' ID to be generated and stored in metadata.
Since introduce of new 'segtype' cache+CACHE_USES_CACHEVOL we can
safely assume 'new' cache with cachevol will now be created
without extra metadata_id and data_id in metadata.
For backward compatibility, code still reads them in case older
version of metadata have them - so it still should be able
to activate such volumes.
Bonus is lowered size of lv structure used to store info about LV
(noticable with big volume groups).
Enhance activation of cached devices using cachevol.
Correctly instatiace cachevol -cdata & -cmeta devices with
'-' in name (as they are only layered devices).
Code is also a bit more compacted (although still not ideal,
as the usage of extra UUIDs stored in metadata is troublesome
and will be repaired later).
NOTE: this patch my brink potentially minor incompatiblity for 'runtime' upgrade