For proper functionality of insert_layer_for_lv we need to
move more bits to layerd LV.
Add some missing new types and correct usage of caller,
so the new LV type is set after the movement.
Validate cache origin in front of the prompt.
Also add some rules to command description file.
TODO:
more validation needed also for lvcreate,
more complex rules with "OR" seems to be needed.
Enable support to cache thin/error/zero virtual targets.
Use can now select whether he want to cache whole thin-pool,
or an individual thin volume out of whole thin-pool.
Support using zero and error LVs as data volume for
cachepool is possibly useful for benchmarking, not much
can be expected from such setup.
Avoid activation when going to skip zeroing of 'error' segtype
(so it's not erroring out).
Also skip zeroing for 'zero' segtype LV (already being zero).
When lvm2 calculates the maximal usable COW size and crops the user
requested size to this value, don't return the error result from
the 'lvextend' operation.
We already apply the same logic when resizing thin-pool beyond
the supported maximal size.
FIXME: The return code error logic here is somewhat fuzzy.
Output from vdo manager may actually indent output with spaces,
so trim leading and ending space.
Also add support for verbosity flag for vdo conversion tool.
This vdo parameter existed in the early stage of integration of vdo into lvm2,
but later it's been removed from vdoformat tool - so actually if
there would be any non-zero value it would cause error on lvcreate.
Option was not stored on disk in lvm2 metadata.
Remove this vdo parameter from lvm2 sources.
(Although this vdo parameter will be still accepted on cmdline through
--vdosettings option, but it will be ignored.)
Fix the testing logic.
With raid5 device the layout of files on a filesystem does not define
which leg will actually contain the block we try to damage.
So test will now figure out which device has damaged block.
Use 'check' functionality and also drop unneeded random write as we
now can identify easily in other way.
Compilation may configure it's own /etc path so ensure the test
has a defined location for access to this dir during testing.
Also prepare machine_id filei (with the use of uuidgen tool)
for the test.
Ensure the volume after conversion has the properly aligned size to the
volume group extent size. This would be visible when using virtual size,
that cannot be divided by extent size.
Before the user had to manually adjust the size after conversion to get
access to all data stored on VDO volume.
The command "lvcreate --type thin --snapshot ..." to create a thin
snapshot would fail.
commit d651b340e6 removed the optional
"--type thin" from the command definition "lvcreate --snapshot LV_thin",
and added --type thin as AUTOTYPE. This was correct and should not have
changed anything if all the command defs were correct, but it broke
the "lvcreate --type thin --snapshot" case. It reveals a problem in a
different command definintion: "lvcreate --type thin LV_thin" that was
missing --snapshot in its OO list.
If we want to have const structure - use a const pointer to avoid,
however making individual members const make it only assingle
in construct time and we already violate this logic since
we memcpy into the structure - so drop these unnecessary consts...
Add support for usage of 'dm-snapshot' for doing whole device conversion
in a snapshot which could be merged once the whole conversion has been
made.
This helps with cases where there would be any unexpected failure in the
middle of conversion process and user can continue using original
device until problem in conversion is fixed.
Import tool now uses 'truncate' tool to create a small backend file (20M) for loop device
to hold COW exception store.
Option --vdo-config has been added to allow specifing location of vdo
configuration file.
Option --no-snapshot allows to use import tool without creation of
snapshot, however recovery after finished VDO conversion and unfinished
lvm2 conversion is then very difficult.
Option --uuid-prefix allow to specify DM UUID prefix for snapshot
device.
Use read with -r.
Improve metadata parser to handle volume_geometry bio_offset,
which needs to be substracted from 'region' start_block when present.
This bio_offset block is non-zero i.e. with converted VDO volumes.
Also fix some converted structure value (but they are not in use).
Fix in the code that matches devices to system.devices entries when
the devices have the same serial number. A non-PV device in
system.devices has no pvid value, and the code was segfaulting
when checking the null pvid value.