IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Sun May 3 11:40:51 CEST 2009 Petr Rockai <me@mornfall.net>
* Convert the straight instances of vg_lock_and_read to new vg_read(_for_update).
Author: Petr Rockai <prockai@redhat.com>
Committer: Dave Wysochanski <dwysocha@redhat.com>
Is an application uses query and set major:minor
to device, it should not fallback to default major by default.
Add new function whoich allows that (and use it in lvm2).
E.g.
# vgscan
Parse error at byte 2360 (line 54): expected a value
Failed to load config file /etc/lvm/lvm.conf
You have a memory leak (not released memory pool):
[0x818c788] library (12 bytes)
...
Several commands calls process_each_vg() and in provided
callback it explicitly recovers VG if inconsistent.
(vgchange, vgconvert, vgscan)
It means that old VG is released and reread but the function
above (process_one_vg) tries to unlock and release old VG.
Patch moves the repair logic into _process_one_vg() function.
It always tries to read vg (even inconsistent) and then decides
what to do according new defined parameter.
Also patch unifies inconsistent error messages.
The only slight change if for vgremove command, where
it now tries to repair VG before it removes if force arg is given.
(It works similar way before, just the order of operation changed).
When mirror convert polling is started (mainly as backgound process,
in lvchange -a y or in lvconvert itself) it tries to read VG
and LV identified by its name.
Unfortunatelly, the VG can have already different LV under the same name,
and various more or less funny things can happen (note that
_finish_lvconvert_mirror suspends the volume for example).
(the typical example is our testing script which continuously recreates
LVs under the same name in the same VG.)
This patch adds optional uuid parameter which helps to properly
select the monitoring object. For lvconvert polling it is set to LV UUID
and both _get_lvconvert_vg and _get_lvconvert_lv uses it to read proper VG/LV.
(In the pvmove case it is NULL, here we poll for physical volume name).
During vgreduce is failed mirror image replaced with error segment,
this segmant type has always area_count == 0.
Current code expects that there is at least one area with device,
patch fixes it by additional check (fixes segfault during vgreduce).
Also do not calculate readahead in every lv_info call, we only need
to cache PV readahead before activation calls which locks memory.
Use lvconvert --repair in dmeventd mirror DSO.
for now.
It replaces bad behaviour in one set of circumstances with bad behaviour
in a different set. We think the behaviour needs to be more configurable.
When we are stacking LV over device, which has for some reason
increased read_ahead (e.g. MD RAID), the read_ahead hint
for libdevmapper is wrong (it is zero).
If the calculated read_ahead hint is zero, patch uses read_ahead of underlying device
(if first segment is PV) when setting DM_READ_AHEAD_MINIMUM_FLAG.
Because we are using dev-cache, it also store this value to cache for future use
(if several LVs are over one PV, BLKRAGET is called only once for underlying device.)
This should fix all the reamining problems with readahead mismatch reported
for DM over MD configurations (and similar cases).
Current code, when need to ensure that volume is not
active on remote node, it need to try to exclusive
activate volume.
Patch adds simple clvmd command which queries all nodes
for lock for given resource.
The lock type is returned in reply in text.
(But code currently uses CR and EX modes only.)
This means two things:
1) Non-mirrored LVs will be no longer affected by mirror monitoring. (Before,
if you had a LV that went partially missing on a VG where a mirror leg failed,
this LV would be removed automatically by dmeventd... Probably not an
unrecoverable dataloss bug, but still quite unpleasant.)
2) If enough parallel PV space is available at the time of the mirror failure,
the failed devices will be automatically replaced using this spare space. Which
(and whether) free space may be used is still not configurable, but is a
planned feature. Since it is relatively easy to undo the action by converting
the mirror manually, I don't consider this to be a showstopper. In fact, I
think the compromise is much better than what we have now.
pvmove now keep suspended devices if temporary mirror creation fails.
We can try to restore previous state if it is first attempt to activate
pvmove (code basically run the same code as --abort automatically).