Calling pvscan --cache with -aay on a PV without an MDA would spuriously fail
with an internal error, because of an incorrect assumption that a parsed VG
structure was always available. This is not true and the autoactivation handler
needs to call vg_read to obtain metadata in cases where the PV had no MDAs to
parse. Therefore, we pass vgid into the handler instead of the (possibly NULL)
VG coming from the PV's MDA.
Arghh, this was bad last-minute shortening of if() expression
in the commit 1ef9831018.
dm_tree_node_set_thin_pool_discard() must not run in the same
expression as check for non-power-2 discard, otherwise
there are 2 calls for dm_tree_node_set_thin_pool_discard
and whole setting of discards is missinterpretted.
In-relase fix it by using proper parentheses {}.
Function _ignore_blocked_mirror_devices was not release
allocated strings images_health and log_health.
In error paths it was also not releasing dm_task structure.
Swaped return code of _ignore_blocked_mirror_devices and
use 1 as success.
In _parse_mirror_status use log_error if memory allocation
fails and few more errors so they are no going unnoticed
as debug messages.
On error path always clear return values and free strings.
For dev_create_file use cache mem pool to avoid memleak.
In case we don't want to activate, autoactivate or have the
VG/LV read-only. Primarily targeted for the auto_activation_volume_list,
but it makes no harm for other settings (the part of the code
that reads these three settings is shared, but there's no
reason to separate it only for this change).
Rework thin feature detection to support runtime
section to allow to disable them selectively.
New lvm.conf option is born: global/thin_disabled_features
$ export DM_DISABLE_UDEV=1
$ dmsetup create test --table "0 1 zero"
Udev is running and DM_DISABLE_UDEV environment variable is set. Bypassing udev, device-mapper library will manage device nodes in device directory.
$ lvchange -ay vg/lvol0
Udev is running and DM_DISABLE_UDEV environment variable is set. Bypassing udev, LVM will manage logical volume symlinks in device directory.
Udev is running and DM_DISABLE_UDEV environment variable is set. Bypassing udev, LVM will obtain device list by scanning device directory.
Udev is running and DM_DISABLE_UDEV environment variable is set. Bypassing udev, device-mapper library will manage device nodes in device directory.
Setting this environment variable will cause a full fallback
to old direct node and symlink management in libdevmapper and lvm2.
It means:
- disabling udev synchronization
(--noudevsync in dmsetup and --noudevsync + activation/udev_sync=0
lvm2 config)
- disabling dm and any subsystem related udev rules
(--noudevrules in dmsetup and activation/udev_rules=0 lvm2 config)
- management of nodes/symlinks under /dev directly by libdevmapper/lvm2
(--verifyudev in dmsetup and activation/verify_udev_operations=1
lvm2 config)
- not obtaining any device list from udev database
(devices/obtain_device_list_from_udev=0 lvm2 config)
Note: we could set all of these before - there's no functional change!
However the DM_DISABLE_UDEV environment variable is a nice shortcut
to make it easier for libdevmapper users so that one can switch off all
of the udev management off at one go directly on the command line,
without a need to modify any source or add any extra switches.
Allow restoring metadata with thin pool volumes.
No validation is done for this case within vgcfgrestore tool -
thus incorrect metadata may lead to destruction of pool content.
Configurable settings for thin pool create
if they are not specified on command line.
New supported lvm.conf options are:
allocation/thin_pool_chunk_size
allocation/thin_pool_discards
allocation/thin_pool_zero
Check if target supports discards for chunk sizes,
that are not power of 2 (just multiple of 64K),
and enable it in case it's supported by thin kernel target.
Commit bf2741376d started to use
lv_is_active() instead of call for lv_info & info.exists so
we cover also cluster activated devices.
For snapshost the conversion was not correct and introduced
regression by blocking creation of snapshot of inactive LV.
Fix it by assigning lv_is_active() directly.
Note: we still have minor issue to fix - to make
lv_is_???? function able to return error states since
lv_info() may fail.
Target tells us its version, and we may allow different set of options
to be supported with different version of driver.
Idea is to provide individual feature flags and later be
able to query for them.
Commit 9fd7ac7d03 did not handle mirrors
that contained mirrored logs. This is because the status line of the
mirror does not give an indication of the health of the mirrored log,
as you can see here:
[root@bp-01 lvm2]# dmsetup status vg-lv vg-lv_mlog
vg-lv: 0 409600 mirror 2 253:6 253:7 400/400 1 AA 3 disk 253:5 A
vg-lv_mlog: 0 8192 mirror 2 253:3 253:4 7/8 1 AD 1 core
Thus, the possibility for LVM commands to hang still persists when mirror
have mirrored logs. I discovered this while performing some testing that
does polling with 'pvs' while doing I/O and killing devices. The 'pvs'
managed to get between the mirrored log device failure and the attempt
by dmeventd to repair it. The result was a very nasty block in LVM
commands that is very difficult to remove - even for someone who knows
what is going on. Thus, it is absolutely essential that the log of a
mirror be recursively checked for mirror devices which may be failed
as well.
Despite what the code comment says in the aforementioned commit...
+ * _mirrored_transient_status(). FIXME: It is unable to handle mirrors
+ * with mirrored logs because it does not have a way to get the status of
+ * the mirror that forms the log, which could be blocked.
... it is possible to get the status of the log because the log device
major/minor is given to us by the status output of the top-level mirror.
We can use that to query the log device for any DM status and see if it
is a mirror that needs to be bypassed. This patch does just that and is
now able to avoid reading from mirrors that have failed devices in a
mirrored log.
Addresses: rhbz855398 (Allow VGs to be built on cluster mirrors),
and other issues.
The LVM code attempts to avoid reading labels from devices that are
suspended to try to avoid situations that may cause the commands to
block indefinitely. When scanning devices, 'ignore_suspended_devices'
can be set so the code (lib/activate/dev_manager.c:device_is_usable())
checks any DM devices it finds and avoids them if they are suspended.
The mirror target has an additional mechanism that can cause I/O to
be blocked. If a device in a mirror fails, all I/O will be blocked
by the kernel until a new table (a linear target or a mirror with
replacement devices) is loaded. The mirror indicates that this condition
has happened by marking a 'D' for the faulty device in its status
output. This condition must also be checked by 'device_is_usable()' to
avoid the possibility of blocking LVM commands indefinitely due to an
attempt to read the blocked mirror for labels.
Until now, mirrors were avoided if the 'ignore_suspended_devices'
condition was set. This check seemed to suggest, "if we are concerned
about suspended devices, then let's ignore mirrors altogether just
in case". This is insufficient and doesn't solve any problems. All
devices that are suspended are already avoided if
'ignore_suspended_devices' is set; and if a mirror is blocking because
of an error condition, it will block the LVM command regardless of the
setting of that variable.
Rather than avoiding mirrors whenever 'ignore_suspended_devices' is
set, this patch causes mirrors to be avoided whenever they are blocking
due to an error. (As mentioned above, the case where a DM device is
suspended is already covered.) This solves a number of issues that weren't
handled before. For example, pvcreate (or any command that does a
pv_read or vg_read, which eventually call device_is_usable()) will be
protected from blocked mirrors regardless of how
'ignore_suspended_devices' is set. Additionally, a mirror that is
neither suspended nor blocking is /allowed/ to be read regardless
of how 'ignore_suspended_devices' is set. (The latter point being the
source of the fix for rhbz855398.)
The heading 'Copy%' is specific to PVMOVE volumes, but can be generalized
to apply to LVM mirrors also. It is a bit awkward to use 'Copy%' for
RAID 4/5/6, however - 'Sync%' would be more appropriate. This is why
RAID 4/5/6 have not displayed their sync status by any means available to
'lvs' yet.
Example (old):
[root@hayes-02 lvm2]# lvs vg
LV VG Attr LSize Pool Origin Data% Move Log Cpy%Sy Convert
lv vg -wi-a---- 1.00g
raid1 vg rwi-a-r-- 1.00g 100.00
raid4 vg rwi-a-r-- 1.01g
raid5 vg rwi-a-r-- 1.01g
raid6 vg rwi-a-r-- 1.01g
This patch changes the heading to 'Cpy%Sync' and allows RAID 4/5/6 to print
their sync percent in this field.
Example (new):
[root@hayes-02 lvm2]# lvs vg
LV VG Attr LSize Pool Origin Data% Move Log Cpy%Sync Convert
lv vg -wi-a---- 1.00g
raid1 vg rwi-a-r-- 1.00g 100.00
raid4 vg rwi-a-r-- 1.01g 100.00
raid5 vg rwi-a-r-- 1.01g 100.00
raid6 vg rwi-a-r-- 1.01g 100.00
The 'copy_percent' function takes the 'extents_copied' field from each
segment in an LV to create the numerator for the ratio that is to
become the copy_percent. (Otherwise known as the 'sync' percent for
non-pvmove uses, like mirror LVs and RAID LVs.) This function safely
works on RAID - not just mirrors - so it is better to have it in
lv_manip.c rather than mirror.c.
There's a lot of different functions that do a lot of different things
in lv_manip.c, so I placed the function near a function in lv_manip.c
that it was close to in metadata-exported.h. Different placement in the
file or a different name for the function may be useful.
Use log_warn to print non-fatal warning messages.
Use of log_error would confuse checker for testing
whether proper error has been reported for some real error.
A message is printed when the region_size of a RAID LV is adjusted
to allow for large (> ~1TB) LVs. The message wasn't very clear.
Hopefully, this is better.
When valgrind usage is desired by user (--enable-valgrind-pool)
skip playing/closing/reopenning with descriptors - it makes
valgridng useless.
Make sleep delay for clvmd start longer.
Use configure --enable-python_bindings to generate them.
Note that the Makefiles do not yet control the owner or permissions of
the two new files on installation.
It would be possible to activate a RAID LV exclusively in a cluster
volume group, but for now we do not allow RAID LVs to exist in a
clustered volume group at all. This has two components:
1) Do not allow RAID LVs to be created in a clustered VG
2) Do not allow changing a VG from single-machine to clustered
if there are RAID LVs present.
MD's bitmaps can handle 2^21 regions at most. The RAID code has always
used a region_size of 1024 sectors. That means the size of a RAID LV was
limited to 1TiB. (The user can adjust the region_size when creating a
RAID LV, which can affect the maximum size.) Thus, creating, extending or
converting to a RAID LV greater than 1TiB would result in a failure to
load the new device-mapper table.
Again, the size of the RAID LV is not limited by how much space is allocated
for the metadata area, but by the limitations of the MD bitmap. Therefore,
we must adjust the 'region_size' to ensure that the number of regions does
not exceed the limit. I've added code to do this when extending a RAID LV
(which covers 'create' and 'extend' operations) and when up-converting -
specifically from linear to RAID1.
We were using daemon_send_simple until now, but it is no longer adequate, since
we need to manipulate requests in a generic way (adding a validity token to each
request), and the tree-based request interface is much more suitable for this.
- move common dm_config_tree manipulation functions from lvmetad-core to
daemon-shared
- add config-tree-based request manipulation APIs to daemon-client
- factor out _v (va_list) variants of most variadic functions in libdaemon
Don't try to issue discards to a missing PV to avoid segfault.
Prevent lvremove from removing LVs that have any part missing.
https://bugzilla.redhat.com/857554
Failing to clear the LV_NOTSYNCED flag when converting a RAID1 LV to
linear can result in the flag being present after an upconvert - even
if the sync is performed when upconverting.
Mirrors do not allow upconverting if the LV has been created with --nosync.
We will enforce the same rule for RAID1. It isn't hugely critical, since
the portions that have been written will be copied over to the new device
identically from either of the existing images. However, the unwritten
sections may be different, causing the added image to be a hybrid of the
existing images.
Also, we are disallowing the addition of new images to a RAID1 LV that has
not completed the initial sync. This may be different from mirroring, but
that is due to the fact that the 'mirror' segment type "stacks" when adding
a new image and RAID1 does not. RAID1 will rebuild a newly added image
"inline" from the existant images, so they should be in-sync.
We cannot add images to a RAID array while it is not in-sync. The
kernel will simply reject the table, saying:
'rebuild' specified while array is not in-sync
Now we check to ensure the LV is in-sync before attempting image
additions.
It is necessary when creating a RAID LV to clear the new metadata areas.
Failure to do so could result in a prepopulated bitmap that would cause
the new array to skip syncing portions of the array. It is a requirement
that the metadata LVs be activated and cleared in the process of creating.
However in test mode, this requirement should be lifted - no new LVs should
be created or written to.
When printing a message for the user and the lv_segment pointer is available,
use segtype->ops->name() instead of segtype->name. This gives a better
user-readable name for the segment. This is especially true for the
'striped' segment type, which prints "linear" if there is an area_count of
one.
We should check whether the fd is opened before trying to reopen it.
For example, the stdin is closed in test/lib/harness.c causing the
test suite to fail.
Fix setvbuf code by closing and reopening stream before changing buffer.
But we need to review what this code is doing embedded inside a library
function rather than the simpler original form being run independently
at the top of main() by tools that need it.
Accept -q as the short form of --quiet.
Suppress non-essential standard output if -q is given twice.
Treat log/silent in lvm.conf as equivalent to -qq.
Review all log_print messages and change some to
log_print_unless_silent.
When silent, the following commands still produce output:
dumpconfig, lvdisplay, lvmdiskscan, lvs, pvck, pvdisplay,
pvs, version, vgcfgrestore -l, vgdisplay, vgs.
[Needs checking.]
Non-essential messages are shifted from log level 4 to log level 5
for syslog and lvm2_log_fn purposes.
This patch adds support for RAID10. It is not the default at this
stage. The user needs to specify '--type raid10' if they would like
RAID10 instead of stacked mirror over stripe.
Adding couple INTERNAL_ERROR reports for unwanted parameters:
Ensure the 'top' metadata node cannot be NULL for lvmetad.
Make obvious vginfo2 cannot be NULL.
Report internal error if handler and vg is undefined.
Check for handle in poll_vg().
Ensure seg is not NULL in dev_manager_transient().
Report missing read_ahead for _lv_read_ahead_single().
Check for report handler in dm_report_object().
Check missing VG in _vgreduce_single().