1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-21 13:34:40 +03:00
Commit Graph

8 Commits

Author SHA1 Message Date
Tony Asleson
ac2fc7a366 lvmdbusd: Vg.LvCreate* methods, correct return type
The methods were returning an instance of the object instead of the
object path which was causing an exception when the result was returned
with the job object as we are explicity trying to return an object path.

Unit test added which re-creates the issue and verifies the fix.
2016-09-19 15:31:04 -05:00
Tony Asleson
2bb09b4015 lvmdbusd: Be more explicit on return values
The python dbus library tries to make best on what the dbus type is based on
python data type.  Some times it gets this wrong, so we will be explicit.
2016-08-29 15:26:55 -05:00
Tony Asleson
dd5d865020 lvmdbusd: Fix hang when lvm compiled with 'enable-notify-dbus'
The following operations would hang if lvm was compiled with
'enable-notify-dbus' and the client specified -1 for the timeout:

* LV snapshot merge
* VG move
* LV move

This was caused because the implementation of these three dbus methods is
different.  Most of the dbus method calls are executed by gathering information
needed to fulfill it, placing that information on a thread safe queue and
returning.  The results later to be returned to the client with callbacks.
With this approach we can process an arbitrary number of commands without any
of them blocking other dbus commands.  However, the 3 dbus methods listed
above did not utilize this functionality because they were implemented with a
separate thread that handles the fork & exec of lvm.  This is done because these
operations can be very slow to complete.  However, because of this the lvm
command that we were waiting on is trying to call back into the dbus service to
notify it that something changed.  Because the code was blocking the process
that handles the incoming dbus activity the lvm command blocked.  We were stuck
until the client timed-out the connection, which then causes the service to
unblock and continue.  If the client did not have a timeout, we would have been
hung indefinitely.

The fix is to always utilize the worker queue on all dbus methods.  We need to
ensure that lvm is tested with 'enable-notify-dbus' enabled and disabled.
2016-06-28 12:09:28 -05:00
Tony Asleson
b81186e535 lvmdbusd: Add method get_object_path_by_lvm_id
The object manager method get_object_by_lvm_id was used in many cases for
the sole reason of getting the object path for the object.  Instead of
retrieving the object and then calling 'dbus_object_path' on the object, we
are adding a method which returns the object path.
2016-06-10 16:04:43 -05:00
Tony Asleson
b717e8fe1d lvmdbusd: Rename get_object_path_by_lvm_id
Renaming to get_object_path_by_uuid_lvm_id, to clarify that both the uuid
and the lvm id are required.
2016-06-10 15:28:42 -05:00
Tony Asleson
081359f6cd lvmdbusd: Do only 1 refresh for Vg.Change()
Signed-off-by: Tony Asleson <tasleson@redhat.com>
2016-02-25 16:43:56 -06:00
Alasdair G Kergon
0f353e2053 lvmdbus: resync latest changes with original repo 2016-02-18 00:27:57 +00:00
Alasdair G Kergon
5987562cf9 lvmdbus: Add new daemon. 2016-02-17 23:53:35 +00:00