IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
With recent updates for thin pool monitoring in version 169
we lost multiple WARNINGs to be printed in syslog, when
pool crossed 80%, 85%, 90%, 95%, 100%.
Restore this logic as we want to keep user informed more
then just once when 80% boundary is passed.
For more advanced support we need to ensure better logic for calling
external much more advanced script for maintanance of thin-pool.
So this new code ensures:
When thin-pool data or metadata is bigger then 50%,
then with each 5% increment, action is called.
This is independent from autoextend_threshold.
This action always happens when thin-pool is over threshold,
(so no action when it's exactly i.e. 60%).
The only exception is 100% full thin-pool - which invokes 'last'
action.
Since thin-pool occupancy may change also downward, code needs
to also handle possibly reduction of occupancy of thin-pool.
So when usage drop from 90% to 50%, thin-pool will start to call
again action when it will pass 55% threshold.
This give external commands lot of option i.e. to call 'fstrim'
before actual resize is needed.
Default internal logic will stop trying to do any 'rescue' action
when executed command fails.
This will be now fully in hands of external script if such
behaviour is needed.
Instead of stopping monitoring after couple failing retries,
keep monitoring forever, just make larger delays between command
retries (ATM upto ~42 minutes).
So syslog is not spammed too often, yet commands have a chance to
be retried and succeed eventually...
When dmeventd configured command does not start with 'lvm ' prefix,
it's going to be an 'external' command.
In this case we split command by spaces to argv strings.
When thin-pool processes event and 'lvextend --use-policies' fails
rather capture up-to-date new info as the fullness percentage may
have jumped noticable. This way we could use 'more' correct numbers
when checking for thresholds.
Translate log_info() into log_very_verbose() which is macro
supposed to be used by our code.
log_info() is internal macro with eventually some 'symbolic' meaning
in syslogging daemons.
Run umount code only when either thin data or metadata are
above 95% - so if there are resize failures with 60%.
system fill keep running.
Also umount will only be tried with lvm2 LVs.
Foreign users are ATM unsuppored.
If plugin's lvm command execution fails too often (>10 times),
there is no point to torture system more then necessary, just log
and drop monitoring in this case.
Start separating the validation from the action in the basic lvresize
code moved to the library.
Remove incorrect use of command line error codes from lvresize library
functions. Move errors.h to tools directory to reinforce this,
exporting public versions of the error codes in lvm2cmd.h for dmeventd
plugins to use.
Reset counter after thin pool resize failure.
If the pool goes above threshold, support unmounting
of all thin volumes if the lvextend fails to avoid
overfilling of the pool.
Fix some minor outstading issue from thin plugin introduction -
Call dmeventd_lvm2_exit() in failpath for registration.
Add some missing '\n' in syslog messages.