IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
Prohibit conversion of pool device with active thin volumes.
Properly restore active states only for active thin pool volume.
Use new LV_NOSCAN when converting volume into thin pool's metadata.
This patch reinstates the lv_info call to check for open count of
the LV we're removing/deactivating - this was changed with commit 125712b
some time ago and we relied on the ioctl retry logic deeper in the libdm
while calling the exact 'remove' ioctl.
However, there are still some situations in which it's still required to
check for open count before we do any 'remove' actions - this mainly
applies to LVs which consist of several sub LVs, like it is for
virtual snapshot devices.
The commit 1146691 fixed the issue with ordering of actions during
virtual snapshot removal while the snapshot is still open. But
the check for the open status of the snapshot is still prone to
marking the snapshot as in use with an immediate exit even though
this could be a temporary asynchronous open only, most notably
because of udev and its WATCH udev rule with accompanying scans
for the event which is asynchronous. The situation where this crops
up most often is when we're closing the LV that was open for read-write
and then calling lvremove immediately.
This patch reinstates the original lv_info call for the open status
of the LV in the lv_check_not_in_use fn that gets called before
we do any LV removal/deactivation. In addition to original logic,
this patch adds its own retry loop with a delay (25x0.2 seconds)
besides the existing ioctl retry loop.
Split image should have an out-of-sync attr ('I') - always. Even if
the RAID LV has not been written to since the LV was split off, it is
still not part of the group that makes up the RAID and is therefore
"out-of-sync".
Since the virtual snapshot has no reason to stay alive once we
detach related snapshot - deactivate whole thing in front of
snapshot removal - otherwice the code would get tricky for
support in cluster.
The correct full solution would require to have transactions
for libdm operations.
Also enable to the check for snapshot being opened prior
the origin deactivation, otherwise we could easily end
with the origin being deactivate, but snapshot still kept
active, desynchronizing locking state in cluster.
Recognize DM_SUBSYSTEM_UDEV_FLAG0 which for LVM is the "LVM_NOSCAN"
flag that causes the scanning to be skipped (mainly blkid) and
also directs all the foreign rules to be skipped as well.
Important thing here is that the "watch" udev rules is still set
as well as the /dev/disk/by-id content created (which does not
require any scanning to be done). Also, the flag is dropped on
any subsequent event and scanning done...
A common scenario is during new LV creation when we need to wipe the
newly created LV and avoid any udev scanning before this stage otherwise
it could cause the device (the LV) to be claimed by some other subsystem
for which there were stale metadata within LV data.
This patch adds possibility to mark the LV we're just about to wipe with
a flag that gets passed to udev via DM_COOKIE as a subsystem specific
flag - DM_SUBSYSTEM_UDEV_FLAG0 (in this case the subsystem is "LVM")
so LVM udev rules will take care of handling that.
Patch 562ad293fd introduced code regression
when LV was converted to a thin LV with external origin and at the same time,
conversion of LV to a thin pool has been requested.
(RHBZ: #997704)
data_lv needs to be assigned after test for external conversion find pool.
Accept --ignoreskippedcluster with pvs, vgs, lvs, pvdisplay, vgdisplay,
lvdisplay, vgchange and lvchange to avoid the 'Skipping clustered
VG' errors when requesting information about a clustered VG
without using clustered locking and still exit with success.
The messages can still be seen with -v.
lib/metadata/lv_manip.c:_sufficient_pes_free() was calculating the
required space for RAID allocations incorrectly due to double
accounting. This resulted in failure to allocate when available
space was tight.
When RAID data and metadata areas are allocated together, the total
amount is stored in ah->new_extents and ah->alloc_and_split_meta is
set. '_sufficient_pes_free' was adding the necessary metadata extents
to ah->new_extents without ever checking ah->alloc_and_split_meta.
This often led to double accounting of the metadata extents. This
patch checks 'ah->alloc_and_split_meta' to perform proper calculations
for RAID.
This error is only present in the function that checks for the needed
space, not in the functions that do the actual allocation.
Add allocation/thin_pool_chunk_size_calculation lvm.conf
option to select a method for calculating thin pool chunk
sizes and define two possible values - "default" and "performance".
A previous commit (b6bfddcd0a) which
was designed to prevent segfaults during lvextend when trying to
extend striped logical volumes forgot to include calculations for
RAID4/5/6 parity devices. This was causing the 'contiguous' and
'cling_by_tags' allocation policies to fail for RAID 4/5/6.
The solution is to remember that while we can compare
ah->area_count == prev_lvseg->area_count
for non-RAID, we should compare
(ah->area_count + ah->parity_count) == prev_lvseg->area_count
for a general solution.
lvmetad is not yet supported in clustered environment so
disable it automatically if using lvmconf --enable-cluster
and reset it to default value if using lvmconf --disable-cluster.
Also, add a few comments in lvm.conf about locking_type vs. use_lvmetad
if setting it for clustered environment.
The corosync cluster interface for clvmd did not correctly
deal with node up/down events so that when a node was removed
from the cluster clvmd would prevent remote operations
from happening, as it thought the node was up but not
running clvmd.
This patch fixes that code by simplifying the case to node
being up or down - which was the original intention
and is supported by pacemaker and CPG in the higher layers.
Signed-off-by: Christine Caulfield <ccaulfie@redhat.com>
When NULL info struct is passed in - function is usable
as a quick query for lv_is_active_locally() - with a bonus
we may query for layered device.
So it could be seen as a more efficient lv_is_active_locally().
Add internal devtypes reporting command to display built-in recognised
block device types. (The output does not include any additional
types added by a configuration file.)
> lvm devtypes -o help
Device Types Fields
-------------------
devtype_all - All fields in this section.
devtype_name - Name of Device Type exactly as it appears in /proc/devices.
devtype_max_partitions - Maximum number of partitions. (How many device minor numbers get reserved for each device.)
devtype_description - Description of Device Type.
> lvm devtypes
DevType MaxParts Description
aoe 16 ATA over Ethernet
ataraid 16 ATA Raid
bcache 1 bcache block device cache
blkext 1 Extended device partitions
...
The lvm2-activation-net.service was ordered only with respect to iscsi
and fcoe service before. In addition to that, we also need ordering
with respect to lvm2-activation.service to prevent parallel vgchange -aay
runs which may cause some problems during activation.
See also https://bugs.gentoo.org/show_bug.cgi?id=480066.
With this patch, the ordering is firmly set to:
lvm2-activation-early.service -> lvm2-activation.service -> lvm2-activation-net.service
Thanks to Alexander Tsoy for the original patch (modified a bit here):
https://www.redhat.com/archives/lvm-devel/2013-September/msg00049.html
Add more 'realistic' simulation of dlm locking.
Previous version was not capable to maintain multiple locks.
Current version doesn't handle multiqueues for locks,
so the ordering is different.
The same corner cases that exist for snapshots on mirrors exist for
any logical volume layered on top of mirror. (One example is when
a mirror image fails and a non-repair LVM command is the first to
detect it via label reading. In this case, the LVM command will hang
and prevent the necessary LVM repair command from running.) When
a better alternative exists, it makes no sense to allow a new target
to stack on mirrors as a new feature. Since, RAID is now capable of
running EX in a cluster and thin is not active-active aware, it makes
sense to pair these two rather than mirror+thinpool.
As further background, here are some additional comments that I made
when addressing a bug related to mirror+thinpool:
(https://bugzilla.redhat.com/show_bug.cgi?id=919604#c9)
I am going to disallow thin* on top of mirror logical volumes.
Users will have to use the "raid1" segment type if they want this.
This bug has come down to a choice between:
1) Disallowing thin-LVs from being used as PVs.
2) Disallowing thinpools on top of mirrors.
The problem is that the code in dev_manager.c:device_is_usable() is unable
to tell whether there is a mirror device lower in the stack from the device
being checked. Pretty much anything layered on top of a mirror will suffer
from this problem. (Snapshots are a good example of this; and option #1
above has been chosen to deal with them. This can also be seen in
dev_manager.c:device_is_usable().) When a mirror failure occurs, the
kernel blocks all I/O to it. If there is an LVM command that comes along
to do the repair (or a different operation that requires label reading), it
would normally avoid the mirror when it sees that it is blocked. However,
if there is a snapshot or a thin-LV that is on a mirror, the above code
will not detect the mirror underneath and will issue label reading I/O.
This causes the command to hang.
Choosing #1 would mean that thin-LVs could never be used as PVs - even if
they are stacked on something other than mirrors.
Choosing #2 means that thinpools can never be placed on mirrors. This is
probably better than we think, since it is preferred that people use the
"raid1" segment type in the first place. However, RAID* cannot currently
be used in a cluster volume group - even in EX-only mode. Thus, a complete
solution for option #2 must include the ability to activate RAID logical
volumes (and perform RAID operations) in a cluster volume group. I've
already begun working on this.
Creation, deletion, [de]activation, repair, conversion, scrubbing
and changing operations are all now available for RAID LVs in a
cluster - provided that they are activated exclusively.
The code has been changed to ensure that no LV or sub-LV activation
is attempted cluster-wide. This includes the often overlooked
operations of activating metadata areas for the brief time it takes
to clear them. Additionally, some 'resume_lv' operations were
replaced with 'activate_lv_excl_local' when sub-LVs were promoted
to top-level LVs for removal, clearing or extraction. This was
necessary because it forces the appropriate renaming actions the
occur via resume in the single-machine case, but won't happen in
a cluster due to the necessity of acquiring a lock first.
The *raid* tests have been updated to allow testing in a cluster.
For the most part, this meant creating devices with '-aey' if they
were to be converted to RAID. (RAID requires the converting LV to
be EX because it is a condition of activation for the RAID LV in
a cluster.)