1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-22 17:35:59 +03:00
Commit Graph

230 Commits

Author SHA1 Message Date
Jonathan Brassow
a6d13308ec RAID/MIRROR: Honor mirror_segtype_default when upconverting linear LVs
If the user would upconvert a linear LV to a mirror without specifying
the segment type ("--type mirror" vs "--type raid1"), the "mirror"
segment type would be chosen without consulting the 'default_mirror_segtype'
setting in lvm.conf.  This is now used as the basis for determining
which should be used if left unspecified.
2013-06-19 17:50:10 -05:00
Petr Rockai
f65dd341a5 locking: Make it possible to pass down an LV to activation code.
Previously, we have relied on UUIDs alone, and on lvmcache to make getting a
"new copy" of VG metadata fast. If the code which triggers the activation has
the correct VG metadata at hand (the version which is currently on disk), it can
now hand it to the activation code directly.
2013-06-10 17:26:38 +02:00
Jonathan Brassow
06ac797f42 Clean-up: Replace 'lv_is_active' with more correct/specific variants
There are places where 'lv_is_active' was being used where it was
more correct to use 'lv_is_active_locally'.  For example, when checking
for the existance of a kernel instance before asking for its status.
Most of the time these would work correctly.  (RAID is only allowed on
non-clustered VGs at the moment, which means that 'lv_is_active' and
'lv_is_active_locally' would give the same result.)  However, it is
more correct to use the proper variant and it helps with future
scenarios where targets might be allowed exclusively (or clustered) in
a cluster VG.
2013-05-16 10:36:56 -05:00
Peter Rajnoha
4777eb6872 lvconvert: check for snapshot-merge support before merge init 2013-05-16 08:21:57 +02:00
Jonathan Brassow
cbcbb67731 mirror: Fix overly-concerning warning on mirror up-convert failure.
Attempting to up-convert an inactive mirror when there is insufficient
space leads to the following message:
  Unable to allocate extents for mirror(s).
  ABORTING: Failed to remove temporary mirror layer inactive_mimagetmp_3.
  Manual cleanup with vgcfgrestore and dmsetup may be required.
This is caused by a failure to execute the 'deactivate_lv' function in
the error condition.  The deactivate returns an error because the LV is
already inactive.  This patch checks if the LV is activate and calls
deactivate_lv only if it is.  This allows the error cleanup code to work
properly in this condition.

It wasn't that big of a deal anyway, since there was no previous vg_commit
that needed to be reverted.  IOW, no harm was done if the allocation failed.
The message was scary and useless.
2013-04-10 16:47:04 -05:00
Zdenek Kabelac
562ad293fd thin: rework lvconvert
Usage of layer was not the best plan here - for proper devices stack
we have to keep correct reference in volume_group structure and
make the new thin pool LV appear as a new volume.
2013-03-13 15:13:54 +01:00
Zdenek Kabelac
9cf00666b3 thin: cannot use snapshot merge with thinpool 2013-03-13 15:13:54 +01:00
Zdenek Kabelac
0191d99906 thin: assign through structure
Just simplify code.
2013-03-13 15:13:54 +01:00
Zdenek Kabelac
f572bf987e thin: read paramaters in front
Fill paramaters into lvconvert_params -
so we could use it independently on args()
2013-03-13 15:13:54 +01:00
Zdenek Kabelac
82eee72019 thin: lvconvert read params sooner
Move code for reading stripesize and readahead to the
_read_params function.
2013-03-13 15:13:54 +01:00
Zdenek Kabelac
f06dd8725a thin: mark passed args
Keep the flag whether given thin pool argument has been given on command
line or it's been 'estimated'

Call of update_pool_params() must not change cmdline given args and
needs to know this info.

Since there is a need to move this update function into /lib, we cannot
use arg_count().

FIXME: we need some generic mechanism here.
2013-03-13 15:13:54 +01:00
Peter Rajnoha
386886f71c config: refer to config nodes using assigned IDs
For example, the old call and reference:

  find_config_tree_str(cmd, "devices/dir", DEFAULT_DEV_DIR)

...now becomes:

  find_config_tree_str(cmd, devices_dir_CFG)

So we're referring to the named configuration ID instead
of passing the configuration path and the default value
is taken from central config definition in config_settings.h
automatically.
2013-03-06 10:14:33 +01:00
Zdenek Kabelac
b73de73151 thin: lvconvert support for external origin
Add basic support for converting LV into an external origin volume.

Syntax:

lvconvert --thinpool vg/pool  --originname renamed_origin -T origin

It will convert volume  'origin' into a thin volume, which will
use 'renamed_origin' as an external read-only origin.
All read/write into origin will go via 'pool'.

renamed_origin volume is read-only volume, that could be activated
only in read-only mode, and cannot be modified.
2013-02-23 10:38:20 +01:00
Zdenek Kabelac
386f3d5a5e thin: external origin cannot be changed
Do not allow conversion of external origin into writeable LV,
and prohibit changing the external origin size.

If the snapshot origin is also external origin, merge is prohibited.
2013-02-23 10:37:01 +01:00
Jonathan Brassow
0e4ffd9d3b clean-up: Rename lvm.conf setting 'mirror_region_size' to 'raid_region_size'
We have been using 'mirror_region_size' in lvm.conf as the default region
size for RAID logical volumes as well as mirror logical volumes.  Since,
"raid" is more inclusive and representative than "mirror", I have changed
the name of this setting.  We must still check for the old setting and warn
the user if we are overriding it with the new setting if both happen to be
present.
2013-02-20 14:40:17 -06:00
Zdenek Kabelac
15115b61c0 lvconvert: update error path
Update the error path after problems with suspend_lv or vg_commit.
It's not exactly well defined what should happen, and this
code seems to appear in many different instancies<F2> in the
whole source code tree - we should probably pick the best version.
2013-02-05 14:31:34 +01:00
Zdenek Kabelac
be5ad90703 lvconvert: fix accepting second lv name
Do not allow to accept second LV name on lvconvert --thinpool
command line.
2013-02-05 14:31:17 +01:00
Jonathan Brassow
970dfbcd69 RAID: Limit replacement of devices when array is not in-sync.
If a RAID array is not in-sync, replacing devices should not be allowed
as a general rule.  This is because the contents used to populate the
incoming device may be undefined because the devices being read where
not in-sync.  The kernel enforces this rule unless overridden by not
allowing the creation of an array that is not in-sync and includes a
devices that needs to be rebuilt.

Since we cannot know the sync state of an LV if it is inactive, we must
also enforce the rule that an array must be active to replace devices.

That leaves us with the following conditions:
1) never allow replacement or repair of devices if the LV is in-active
2) never allow replacement if the LV is not in-sync
3) allow repair if the LV is not in-sync, but warn that contents may
   not be recoverable.

In the case where a user is performing the repair on the command line via
'lvconvert --repair', the warning is printed before the user is prompted
if they would like to replace the device(s).  If the repair is automated
(i.e. via dmeventd and policy is "allocate"), then the device is replaced
if possible and the warning is printed.
2012-12-18 14:40:42 -06:00
Peter Rajnoha
e8025aa67a lvconvert: also allow --type with --stripes
We can also use this for conversion between different mirror segment
types. Each new segment type converter then needs to check itself
whether the --stripes is applicable.
2012-12-13 11:19:11 +01:00
Peter Rajnoha
cad22be394 lvconvert: allow lvconvert --stripes/stripesize only with -mirrors/--repair/--thinpool
Also, update lvconvert man page to reflect this and make clear that
the --stripes/stripesize is applied to newly allocated space only.
2012-12-11 15:50:25 +01:00
Peter Rajnoha
f942ae4a7a lvconvert: do not ignore -f in lvconvert --repair -y -f 2012-12-11 09:52:54 +01:00
Zdenek Kabelac
99018b37ee thin: lvconvert supports swapping metadata device
Support swapping of metadata device if the thin pool already
exists. This way it's easy to i.e. resize metadata or their
repair operation.

User may create some empty LV, replace existing metadata
or dump and restore them into bigger LV.
2012-12-02 18:01:27 +01:00
Zdenek Kabelac
ade2f47829 thin: deactivate subvolumes
Do not leave active thin data and metadata volumes
if activation of thin pool fails.
2012-12-02 17:56:44 +01:00
Zdenek Kabelac
f0da2842cf thin: shuffle code
Reorder code lines for next patch.
2012-12-02 17:56:44 +01:00
Zdenek Kabelac
0be8a9126f thin: lvconvert update messages 2012-12-02 17:56:44 +01:00
Zdenek Kabelac
c7a7fd0a12 thin: fix attrs for unloaded driver
If the driver is not loaded, set all 'features' ON
instead of all of them being OFF.
2012-11-27 11:29:47 +01:00
Zdenek Kabelac
953080e4fc thin: add more unsupporte options for merge
Hmm, we need some smarter way to detect unsupported command
line options for various commands.
2012-11-26 12:15:32 +01:00
Zdenek Kabelac
b21d3e3592 thin: lvconvert update
Use common function from toollib and support allocation
of metadata LV with give thin pool data LV.
2012-11-19 14:38:17 +01:00
Zdenek Kabelac
cf5242a670 lvconvert: store target attributes
Target tells us its version, and we may allow different set of options
to be supported with different version of driver.

Idea is to provide individual feature flags and later be
able to query for them.
2012-11-19 14:17:10 +01:00
Jonathan Brassow
54c73b7723 mirror: Mirrored log should be fixed before mirror when double fault occurs
This patch is intended to fix bug 825323 - FS turns read-only during a double
fault of a mirror leg and mirrored log's leg at the same time.  It only
affects a 2-way mirror with a mirrored log.  3+-way mirrors and mirrors
without a mirrored log are not affected.

The problem resulted from the fact that the top level mirror was not
using 'noflush' when suspending before its "down-convert".  When a
mirror image fails, the bios are queue until a suspend is recieved.  If
it is a 'noflush' suspend, the bios can be safely requeued in the DM
core.  If 'noflush' is not used, the bios must be pushed through the
target and if a device is failed for a mirror, that means issuing an
error.  When an error is received by a file system, it results in it
turning read-only (depending on the FS).

Part of the problem was is due to the nature of the stacking involved in
using a mirror as a mirror's log.  When an image in each fail, the top
level mirror stalls because it is waiting for a log flush.  The other
stalls waiting for corrective action.  When the repair command is issued,
the entire stacked arrangement is collapsed to a linear LV.  The log
flush then fails (somewhat uncleanly) and the top-level mirror is suspended
without 'noflush' because it is a linear device.

This patch allows the log to be repaired first, which in turn allows the
top-level mirror's log flush to complete cleanly.  The top-level mirror
is then secondarily reduced to a linear device - at which time this mirror
is suspended properly with 'noflush'.
2012-11-14 14:58:47 -06:00
Zdenek Kabelac
f260f99d57 cleanup: switch log_error to log_warn
Use log_warn to print non-fatal warning messages.

Use of log_error would confuse checker for testing
whether proper error has been reported for some real error.
2012-10-17 15:41:35 +02:00
Zdenek Kabelac
5b07bd3f91 lvconvert: disable convertion of thin to mirrors
For now this convertions is not supported, thus disabled.
The only supported conversion for now is to create mirrored thin pools
from mirrored devices.
2012-10-08 12:16:53 +02:00
Zdenek Kabelac
a27650cc98 thin: lvconvert
Update code for lvconvert.
Change the lvconvert user interface a bit - now we require 2 specifiers
--thinpool   takes LV name for data device (and makes the name)
--poolmetadata  takes LV name for metadata device.

Fix type in thin help text -z -> -Z.

Supported is also new flag --discards for thinpools.
2012-10-03 15:13:33 +02:00
Jonathan Brassow
c3eb3a7687 cleanup: Use segtype->ops->name() instead of segtype->name where applicable
When printing a message for the user and the lv_segment pointer is available,
use segtype->ops->name() instead of segtype->name.  This gives a better
user-readable name for the segment.  This is especially true for the
'striped' segment type, which prints "linear" if there is an area_count of
one.
2012-09-05 11:35:54 -05:00
Alasdair G Kergon
438e0050df config: add silent mode
Accept -q as the short form of --quiet.
Suppress non-essential standard output if -q is given twice.
Treat log/silent in lvm.conf as equivalent to -qq.
Review all log_print messages and change some to
log_print_unless_silent.

When silent, the following commands still produce output:
dumpconfig, lvdisplay, lvmdiskscan, lvs, pvck, pvdisplay,
pvs, version, vgcfgrestore -l, vgdisplay, vgs.
[Needs checking.]

Non-essential messages are shifted from log level 4 to log level 5
for syslog and lvm2_log_fn purposes.
2012-08-25 20:35:48 +01:00
Zdenek Kabelac
57c0f72b1d lvconvert: use _reload_lv on more places
Use common subroutine.
2012-08-23 14:38:45 +02:00
Zdenek Kabelac
4698fb0543 lvconvert: move _reload_lv()
Just move in front
2012-08-23 14:37:52 +02:00
Peter Rajnoha
07e4ac7b00 lvconvert: count % upwards when merging a snapshot
Before:
  # lvconvert --merge -i 1 vg/lvol1
  Merging of volume lvol1 started.
  lvol0: Merged: 36.7%
  lvol0: Merged: 21.3%
  lvol0: Merged: 5.8%
  lvol0: Merged: 0.0%
  Merge of snapshot into logical volume lvol0 has finished.
  Logical volume "lvol1" successfully removed

After:
  # lvconvert --merge -i 1 vg/lvol1
  Merging of volume lvol1 started.
  lvol0: Merged: 61.4%
  lvol0: Merged: 73.0%
  lvol0: Merged: 88.4%
  lvol0: Merged: 100.0%
  Merge of snapshot into logical volume lvol0 has finished.
  Logical volume "lvol1" successfully removed
2012-07-10 15:30:18 +02:00
Zdenek Kabelac
6bd3864b41 thin: fix lvconvert error path NULL dereference
For printing the name, use given command line parameter.
2012-06-22 13:50:21 +02:00
Zdenek Kabelac
0a9f894ff0 Initial support for lvconvert for thin pool volumes.
Support has many limitations and lots of FIXMEs inside,
however it makes initial task when user creates a separate LV for
thin pool data and thin metadata already usable, so let's enable
it for testing.

Easiest API:

lvconvert --chunksize XX --thinpool data_lv  metadata_lv

More functionality extensions will follow up.

TODO: Code needs some rework since a lot of same code is getting copied.
2012-05-09 12:17:06 +00:00
Jonathan Earl Brassow
1a53400723 Fix for bug 807776: invalid lvconvert --merge output should mention raid1 now
s/snapshot/mergeable volume/
2012-04-19 21:50:37 +00:00
Peter Rajnoha
543eaed88c Detect VG name being part of the LV name in lvconvert --splitmirrors -n.
Before:
devel/~ # lvconvert --splitmirrors 1 -n vg/splitted_one vg/mirrored_one
  Internal error: LV name vg/splitted_one has invalid form.
  Intermediate VG metadata write failed.

After:
devel/~ # lvconvert --splitmirrors 1 -n vg/splitted_one vg/mirrored_one
  Logical volume mirrored_one converted.

devel/~ # lvconvert --splitmirrors 1 -n abc/splitted_one vg/mirrored_one
  Please use a single volume group name ("vg" or "abc")
  Run `lvconvert --help' for more information.
2012-03-30 08:58:02 +00:00
Zdenek Kabelac
f3c177312f Correct enum type
Using debug_t and some forgetten alloc_policy_t, force_t from past commit.
2012-03-01 21:14:43 +00:00
Zdenek Kabelac
fbf6b89a84 Using enum types for enums
alloc_policy_t, dm_string_mangling_t, percent_range_t, sign_t
2012-02-28 14:24:57 +00:00
Zdenek Kabelac
980cf7959c Keep same sign for 's' counter 2012-02-23 22:36:56 +00:00
Jonathan Earl Brassow
e8eb64c878 Allow 'lvconvert --repair' to operate on RAID 4/5/6.
The higher level RAIDs should be allowed for repair along with 'mirror' and
'raid1' segment types.
2012-02-22 17:18:49 +00:00
Jonathan Earl Brassow
7a5a5cb06f Add some messages that indicate completion of RAID device replacement.
There were no messages printed upon completiion of RAID device replacement.
This could cause confusion/concern during automated recovery, because the
user sees the failure messages but no other messages indicating correction.
2012-02-22 16:03:55 +00:00
Jonathan Earl Brassow
972282bfbc Fix a bad return code in 'lvconvert_raid'
Functions at this level do return 0 or 1, not ECMD_* values.
2012-02-22 15:20:50 +00:00
Jonathan Earl Brassow
96f82296ae Change confusing message that is printed when a RAID device fails.
s/Issue/Use/, otherwise it is easy to misread "Issue" as "Issuing" - causing
the user confusion as to whether the action was performed automatically or
whether they need to issue the command.
2012-02-13 18:38:36 +00:00
Jonathan Earl Brassow
1456c3b298 Fix possible NULL pointer dereferences when updating mirror log.
'_lv_update_log_type' takes a lvconvert_params argument so that it can pass
down the user's preference of 'region_size' and allocation_policy.  When
'mirror_remove_missing' was introduced (commit ID
95986e42a1) it didn't make sense to pass down
user preferences - so NULL was given instead.  While it may never happen in
practice, static analysis reveals that this argument could be dereferenced.
So, if the user preferences were not passed in, glean the necessary fields
from what is already set in the LV.

Reported-by: Zdenek Kabelac <zkabelac@redhat.com>
Signed-off-by: Jonathan Brassow <jbrassow@redhat.com>

(Not updating WHATSNEW for this simple clean-up.)
2012-02-13 18:36:55 +00:00