IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
In log messages refer to it as system ID (not System ID).
Do not put quotes around the system_id string when printing.
On the command line use systemid.
In code, metadata, and config files use system_id.
In lvmsystemid refer to the concept/entity as system_id.
The only realistic way for a host to have active LVs in a
foreign VG is if the host's system_id (or system_id_source)
is changed while LVs are active.
In this case, the active LVs produce an warning, and access
to the VG is implicitly allowed (without requiring --foreign.)
This allows the active LVs to be deactivated.
In this case, rescanning PVs for the VG offers no benefit.
It is not possible that rescanning would reveal an LV that
is active but wasn't previously in the VG metadata.
A foreign VG should be silently ignored by a reporting/display
command like 'vgs'. If the reporting/display command specifies
a foreign VG by name on the command line, it should produce an
error message.
Scanning commands pvscan/vgscan/lvscan are always allowed to
read and update caches from all PVs, including those that belong
to foreign VGs.
Other non-report/display/scan commands always ignore a foreign
VG, or report an error if they attempt to use a foreign VG.
vgimport should always invalidate the lvmetad cache because
lvmetad likely holds a pre-vgexported copy of the VG.
(This is unrelated to using foreign VGs; the pre-vgexported
VG may have had no system_id at all.)
Move the lvm1 sys ID into vg->lvm1_system_id and reenable the #if 0
LVM1 code. Still display the new-style system ID in the same
reporting field, though, as only one can be set.
Add a format feature flag FMT_SYSTEM_ON_PVS for LVM1 and disallow
access to LVM1 VGs if a new-style system ID has been set.
Treat the new vg->system_id as const.
Allow cmd->unknown_system_id to be cleared during toolcontext
refresh.
Set a default value of "none" for global/system_id_source.
Allow local/system_id to be empty so it's not impossible for
a later config file to remove it.
In a file containing a system ID:
Any whitespace at the start of a line is ignored;
Blank lines are ignored;
Any characters after a # are ignored along with the #.
The system ID is obtained by processing the first line with
non-ignored characters.
If further lines with non-ignored characters follow, a warning is
issued.
Add WARNING messages if there are problems setting the requested
system ID.
Ban "localhost" as a prefix regardless of the system_id_source.
Use cmd->hostname instead of calling uname again.
Make system_id_source values case-insensitive (as with new settings like
log_debug_classes) and also accept machine-id to match the filename.
Require system ID to begin with an alphanumeric character.
Rename fn to make clear it's only validation for systemid
and always terminate result rather than imposing this on the caller.
In 2.02.99, _init_tags() inadvertently began to ignore the
dm_config_tree struct passed to it. "tags" sections are not
merged together, so the "tags" section in the main config file was
being processed repeatedly and other "tags" sections were ignored.
Just like MD filtering that detects components of software RAID (md),
add detection for firmware RAID.
We're not adding any native code to detect this - there are lots of
firmware RAIDs out there which is just out of LVM scope. However,
with current changes with which we're able to get device info from
external sources (e.g. external_device_info_source="udev"), we can
do this easily if the external device status source has this kind
of information - which is the case of "udev" source where the results
of blkid scans are stored.
This detection should cover all firmware RAIDs that blkid can detect and
which are identified as:
ID_FS_TYPE = {adaptec,ddf,hpt45x,hpt37x,isw,jmicron,lsi_mega,nvidia,promise_fasttrack,silicon_medley,via}_raid_member
Composite filter is a filter that can put several filters in one set.
This patch adds a switch when creating the composite filter which will
enable or disable external device info handles for all the filters
the composite filter encompasses.
We want to use this external device info for majority of the filters
which are in the "lvmetad filter chain" (or the respective part if
we're not using lvmetad).
Following patches will use the enabled external device handle in
concrete filters from the composite filter...
There are actually three filter chains if lvmetad is used:
- cmd->lvmetad_filter used when when scanning devices for lvmetad
- cmd->filter used when processing lvmetad responses
- cmd->full_fiilter (which is just cmd->lvmetad_filter + cmd->filter chained together) used
for remaining situations
This patch adds the third one - "cmd->full_filter" - currently this is
used if device processing does not fall into any of the groups before,
for example, devices which does not have the PV label yet and we're just
creating a new one or we're processing the devices where the list of the
devices (PVs) is not returned by lvmetad initially.
Currently, the cmd->full_filter is used exactly in these functions:
- lvmcache_label_scan
- _pvcreate_check
- pvcreate_vol
- lvmdiskscan
- pvscan
- _process_each_label
If lvmetad is used, then simply cmd->full_filter == cmd->filter because
cmd->lvmetad_filter is NULL in this case.
We need to use proper filter chain when we disable lvmetad use
explicitly in the code by calling lvmetad_set_active(0) while
overriding existing configuration. We need to reinitialize filters
in this case so proper filter chain is used. The same applies
for the other way round - when we enable lvmetad use explicitly in
the code (though this is not yet used).
With this change, the filter chains used look like this now:
A) When *lvmetad is not used*:
- persistent filter -> regex filter -> sysfs filter ->
global regex filter -> type filter ->
usable device filter(FILTER_MODE_NO_LVMETAD) ->
mpath component filter -> partitioned filter ->
md component filter
B) When *lvmetad is used* (two separate filter chains):
- the lvmetad filter chain used when scanning devs for lvmetad update:
sysfs filter -> global regex filter -> type filter ->
usable device filter(FILTER_MODE_PRE_LVMETAD) ->
mpath component filter -> partitioned filter ->
md component filter
- the filter chain used for lvmetad responses:
persistent filter -> usable device filter(FILTER_MODE_POST_LVMETAD) ->
regex filter
Caused by recent changes - a7be3b12df.
If global filter was not defined, then part of the code
creating composite filter (the cmd->lvmetad_filter) incorrectly
increased index value even if this global filter was not created
as part of the composite filter. This caused a gap with "NULL"
value in the composite filter array which ended up with the rest
of the filters after the gap to be ignored and also it caused a mem
leak when destroying the composite filter.
If a PV label is exposed both through a composite device (MD for example) and
through its component devices, we always want the PV that lvmetad sees to be the
composite, since this is what all LVM commands (including activation) will then
use. If pvscan --cache is triggered for multiple clones of the same PV, the last
to finish wins. This patch basically re-arranges the filters so that
component-device filters are part of the global_filter chain, not of the
client-side filter chain. This has a subtle effect on filter evaluation order,
but should not alter visible semantics in the non-lvmetad case.
Currently, we have two modes of activation, an unnamed nominal mode
(which I will refer to as "complete") and "partial" mode. The
"complete" mode requires that a volume group be 'complete' - that
is, no missing PVs. If there are any missing PVs, no affected LVs
are allowed to activate - even RAID LVs which might be able to
tolerate a failure. The "partial" mode allows anything to be
activated (or at least attempted). If a non-redundant LV is
missing a portion of its addressable space due to a device failure,
it will be replaced with an error target. RAID LVs will either
activate or fail to activate depending on how badly their
redundancy is compromised.
This patch adds a third option, "degraded" mode. This mode can
be selected via the '--activationmode {complete|degraded|partial}'
option to lvchange/vgchange. It can also be set in lvm.conf.
The "degraded" activation mode allows RAID LVs with a sufficient
level of redundancy to activate (e.g. a RAID5 LV with one device
failure, a RAID6 with two device failures, or RAID1 with n-1
failures). RAID LVs with too many device failures are not allowed
to activate - nor are any non-redundant LVs that may have been
affected. This patch also makes the "degraded" mode the default
activation mode.
The degraded activation mode does not yet work in a cluster. A
new cluster lock flag (LCK_DEGRADED_MODE) will need to be created
to make that work. Currently, there is limited space for this
extra flag and I am looking for possible solutions. One possible
solution is to usurp LCK_CONVERT, as it is not used. When the
locking_type is 3, the degraded mode flag simply gets dropped and
the old ("complete") behavior is exhibited.
The --binary option, if used, causes all the binary values reported
in reporting commands to be displayed as "0" or "1" instead of descriptive
literal values (value "unknown" is still used for values that could not be
determined).
Also, add report/binary_values_as_numeric lvm.conf option with the same
functionality as the --binary option (the --binary option prevails
if both --binary cmd option and report/binary_values_as_numeric lvm.conf
option is used at the same time). The report/binary_values_as_numeric is
also profilable.
This makes it easier to use and check lvm reporting command output in scripts.
The list of strings is used quite frequently and we'd like to reuse
this simple structure for report selection support too. Make it part
of libdevmapper for general reuse throughout the code.
This also simplifies the LVM code a bit since we don't need to
include and manage lvm-types.h anymore (the string list was the
only structure defined there).
- When defining configuration source, the code now uses separate
CONFIG_PROFILE_COMMAND and CONFIG_PROFILE_METADATA markers
(before, it was just CONFIG_PROFILE that did not make the
difference between the two). This helps when checking the
configuration if it contains correct set of options which
are all in either command-profilable or metadata-profilable
group without mixing these groups together - so it's a firm
distinction. The "command profile" can't contain
"metadata profile" and vice versa! This is strictly checked
and if the settings are mixed, such profile is rejected and
it's not used. So in the end, the CONFIG_PROFILE_COMMAND
set of options and CONFIG_PROFILE_METADATA are mutually exclusive
sets.
- Marking configuration with one or the other marker will also
determine the way these configuration sources are positioned
in the configuration cascade which is now:
CONFIG_STRING -> CONFIG_PROFILE_COMMAND -> CONFIG_PROFILE_METADATA -> CONFIG_FILE/CONFIG_MERGED_FILES
- Marking configuration with one or the other marker will also make
it possible to issue a command context refresh (will be probably
a part of a future patch) if needed for settings in global profile
set. For settings in metadata profile set this is impossible since
we can't refresh cmd context in the middle of reading VG/LV metadata
and for each VG/LV separately because each VG/LV can have a different
metadata profile assinged and it's not possible to change these
settings at this level.
- When command profile is incorrect, it's rejected *and also* the
command exits immediately - the profile *must* be correct for the
command that was run with a profile to be executed. Before this
patch, when the profile was found incorrect, there was just the
warning message and the command continued without profile applied.
But it's more correct to exit immediately in this case.
- When metadata profile is incorrect, we reject it during command
runtime (as we know the profile name from metadata and not early
from command line as it is in case of command profiles) and we
*do continue* with the command as we're in the middle of operation.
Also, the metadata profile is applied directly and on the fly on
find_config_tree_* fn call and even if the metadata profile is
found incorrect, we still need to return the non-profiled value
as found in the other configuration provided or default value.
To exit immediately even in this case, we'd need to refactor
existing find_config_tree_* fns so they can return error. Currently,
these fns return only config values (which end up with default
values in the end if the config is not found).
- To check the profile validity before use to be sure it's correct,
one can use :
lvm dumpconfig --commandprofile/--metadataprofile ProfileName --validate
(the --commandprofile/--metadataprofile for dumpconfig will come
as part of the subsequent patch)
- This patch also adds a reference to --commandprofile and
--metadataprofile in the cmd help string (which was missing before
for the --profile for some commands). We do not mention --profile
now as people should use --commandprofile or --metadataprofile
directly. However, the --profile is still supported for backward
compatibility and it's translated as:
--profile == --metadataprofile for lvcreate, vgcreate, lvchange and vgchange
(as these commands are able to attach profile to metadata)
--profile == --commandprofile for all the other commands
(--metadataprofile is not allowed there as it makes no sense)
- This patch also contains some cleanups to make the code handling
the profiles more readable...
When cmd refresh is called, we need to move any already loaded profiles
to profiles_to_load list which will cause their reload on subsequent
use. In addition to that, we need to take into account any change
in config/profile configuration setting on cmd context refresh
since this setting could be overriden with --config.
Also, when running commands in the shell, we need to remove the
global profile used from the configuration cascade so the profile
is not incorrectly reused next time when the --profile option is
not specified anymore for the next command in the shell.
This bug only affected profile specified by --profile cmd line
arg, not profiles referenced from LVM metadata.
Before, the cft_check_handle used to direct configuration checking
was part of cmd_context. It's better to attach this as part of the
exact config tree against which the check is done. This patch moves
the cft_check_handle out of cmd_context and it attaches it to the
config tree directly as dm_config_tree->custom->config_source->check_handle.
This change makes it easier to track the config tree check results
and provides less space for bugs as the results are directly attached
to the tree and we don't need to be cautious whether the global value
is correct or not (and whether it needs reinitialization) as it was
in the case when the cft_check_handle was part of cmd_context.
When lvm2 command works with clvmd and uses locking in wrong way,
it may 'leak' certain file descriptors in opened (incorrect) state.
dev_cache_exit then destroys memory pool of cached devices, while
_open_devices list in dev-io.c was still referencing them if they
were still opened.
Patch properly calls _close() function to 'self-heal' from this
invalid state, but it will report internal error (so execution
with abort_on_internal_error causes immediate death). On the
normal 'execution', error is only reported, but memory state is
corrected, and linked list is not referencing devices from
released mempool.
For crash see: https://bugzilla.redhat.com/show_bug.cgi?id=1073886
Since commit f12ee43f2e call destroy,
it start to check all VGs are unlocked. However when we become_daemon,
we simply reset locking (since lock is still kept by parent process).
So implement a simple 'reset' flag.
The global/suffix was missing from example lvm.conf but it can
be very useful when using lvm in scripts and now in profiles as well
Let's expose it more.
The devices/cache and devices/cache_dir are evaluated in runtime this way:
- if devices/cache is set, use it
- if devices_cache/dir or devices/cache_file_prefix is set, make up a
path out of that for devices/cache in runtime, taking into account
the LVM_SYSTEM_DIR environment variable if set
- otherwise make up the path out of default which is:
<LVM_SYSTEM_DIR>/<cache_dir>/<cache_file_prefix>.cache
With the runtime defaults, we can encode this easily now. Also, the lvm
dumpconfig can show proper and exact information about this setting then
(the variant that shows default values).