1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-21 13:34:40 +03:00
Commit Graph

268 Commits

Author SHA1 Message Date
Ondrej Kozina
c3d351ec9b new debug class for lvmpolld client code 2015-05-12 17:16:37 +02:00
Ondrej Kozina
e587b0677b lvmpolld: Add standalone polldaemon.
See doc/lvmpolld_overview.txt
2015-05-09 00:59:18 +01:00
Alasdair G Kergon
87941ccd17 systemid: Use correct mempool.
libmem is necessary when this ends up in cmd->system_id.
2015-03-18 23:25:30 +00:00
Zdenek Kabelac
1260b86b2b config: use timestamp with nanosecond precision
Since kernel 2.6 we can use more precise timestamping,
so e.g. we could better recognize configs are slightly
older then generated .cache file.
2015-03-18 13:42:56 +01:00
David Teigland
c32efc7f7e system_id: apply consistent naming
In log messages refer to it as system ID (not System ID).

Do not put quotes around the system_id string when printing.

On the command line use systemid.

In code, metadata, and config files use system_id.

In lvmsystemid refer to the concept/entity as system_id.
2015-02-27 13:32:00 -06:00
David Teigland
dd6a202831 lvchange: deactivate is always possible in foreign vgs
The only realistic way for a host to have active LVs in a
foreign VG is if the host's system_id (or system_id_source)
is changed while LVs are active.

In this case, the active LVs produce an warning, and access
to the VG is implicitly allowed (without requiring --foreign.)
This allows the active LVs to be deactivated.

In this case, rescanning PVs for the VG offers no benefit.
It is not possible that rescanning would reveal an LV that
is active but wasn't previously in the VG metadata.
2015-02-25 14:58:49 -06:00
David Teigland
8668a9e81c systemid: silently ignore foreign vgs unless named
A foreign VG should be silently ignored by a reporting/display
command like 'vgs'.  If the reporting/display command specifies
a foreign VG by name on the command line, it should produce an
error message.

Scanning commands pvscan/vgscan/lvscan are always allowed to
read and update caches from all PVs, including those that belong
to foreign VGs.

Other non-report/display/scan commands always ignore a foreign
VG, or report an error if they attempt to use a foreign VG.

vgimport should always invalidate the lvmetad cache because
lvmetad likely holds a pre-vgexported copy of the VG.
(This is unrelated to using foreign VGs; the pre-vgexported
VG may have had no system_id at all.)
2015-02-25 10:53:52 -06:00
Alasdair G Kergon
4ff9abd01f toolcontext: Fix lvmlocal.conf load fail path. 2015-02-25 16:36:47 +00:00
Alasdair G Kergon
ac6a4cd707 systemid: Allow empty systemid with warnings.
Add warning messages when empty system ID is set.
2015-02-25 14:12:24 +00:00
Alasdair G Kergon
df227be37c lvm1: Reenable sys ID.
Move the lvm1 sys ID into vg->lvm1_system_id and reenable the #if 0
LVM1 code.  Still display the new-style system ID in the same
reporting field, though, as only one can be set.
Add a format feature flag FMT_SYSTEM_ON_PVS for LVM1 and disallow
access to LVM1 VGs if a new-style system ID has been set.
Treat the new vg->system_id as const.
2015-02-23 23:03:52 +00:00
Alasdair G Kergon
3d406e5a8d config: Adjust system_id defaults.
Allow cmd->unknown_system_id to be cleared during toolcontext
refresh.
Set a default value of "none" for global/system_id_source.
Allow local/system_id to be empty so it's not impossible for
a later config file to remove it.
2015-02-23 21:20:51 +00:00
Alasdair G Kergon
e15b439bf3 systemid: Define file content more precisely.
In a file containing a system ID:
  Any whitespace at the start of a line is ignored;
  Blank lines are ignored;
  Any characters after a # are ignored along with the #.
  The system ID is obtained by processing the first line with
non-ignored characters.
  If further lines with non-ignored characters follow, a warning is
issued.
2015-02-23 20:49:15 +00:00
Alasdair G Kergon
c2ed5feee5 systemid: Add warnings if invalid.
Add WARNING messages if there are problems setting the requested
system ID.
Ban "localhost" as a prefix regardless of the system_id_source.
Use cmd->hostname instead of calling uname again.
Make system_id_source values case-insensitive (as with new settings like
log_debug_classes) and also accept machine-id to match the filename.
2015-02-23 20:36:27 +00:00
Alasdair G Kergon
6b6934b009 toolcontext: Include system_id in refresh.
Move _init_system_id() into _process_config() so it's also called when
refreshing the toolcontext.  Add WARNING to log_warn messages.
2015-02-23 20:21:00 +00:00
Alasdair G Kergon
72e6888dc3 toolcontext: Move lvmlocal.conf loading.
Load lvmlocal.conf after basic initialisation from lvm.conf.
2015-02-23 20:11:00 +00:00
Alasdair G Kergon
0551d1c56e systemid: Require alphanumeric 1st character.
Require system ID to begin with an alphanumeric character.
Rename fn to make clear it's only validation for systemid
and always terminate result rather than imposing this on the caller.
2015-02-23 19:47:03 +00:00
Alasdair G Kergon
2a1189ebc3 config: Reinstate recursive tags setting.
In 2.02.99, _init_tags() inadvertently began to ignore the
dm_config_tree struct passed to it.  "tags" sections are not
merged together, so the "tags" section in the main config file was
being processed repeatedly and other "tags" sections were ignored.
2015-02-23 17:40:58 +00:00
David Teigland
d726246f78 system_id: warn if the system_id_file cannot be opened 2015-02-13 11:37:11 -06:00
David Teigland
8cdec4c434 system_id: use for VG ownership
See included lvmsystemid(7) for full description.
2015-02-13 10:10:27 -06:00
Peter Rajnoha
1c7a509bed filters: add firmware RAID filter
Just like MD filtering that detects components of software RAID (md),
add detection for firmware RAID.

We're not adding any native code to detect this - there are lots of
firmware RAIDs out there which is just out of LVM scope. However,
with current changes with which we're able to get device info from
external sources (e.g. external_device_info_source="udev"), we can
do this easily if the external device status source has this kind
of information - which is the case of "udev" source where the results
of blkid scans are stored.

This detection should cover all firmware RAIDs that blkid can detect and
which are identified as:
  ID_FS_TYPE = {adaptec,ddf,hpt45x,hpt37x,isw,jmicron,lsi_mega,nvidia,promise_fasttrack,silicon_medley,via}_raid_member
2015-01-30 13:17:12 +01:00
Peter Rajnoha
bf8943b0f6 conf: add devices/external_device_info_source to lvm.conf 2015-01-30 13:01:12 +01:00
Peter Rajnoha
c50a90c9e6 filter-composite: add external device info hooks
Composite filter is a filter that can put several filters in one set.
This patch adds a switch when creating the composite filter which will
enable or disable external device info handles for all the filters
the composite filter encompasses.

We want to use this external device info for majority of the filters
which are in the "lvmetad filter chain" (or the respective part if
we're not using lvmetad).

Following patches will use the enabled external device handle in
concrete filters from the composite filter...
2015-01-30 13:01:12 +01:00
Zdenek Kabelac
97cccfbf1c segtype: drop cmdcontex pointer
Users of context provide their cmd pointer,
so don't keep it inside segtype.
2014-10-30 23:58:49 +01:00
Zdenek Kabelac
fd1aa7fd5a segments: disable init of free segment
Since it is not needed and would require separate
code for validation disable its initialization.
2014-10-24 16:39:31 +02:00
Peter Rajnoha
5011cac9cf filters: add cmd->full_filter - composite of cmd->filter and cmd->lvmetad_filter
There are actually three filter chains if lvmetad is used:
  - cmd->lvmetad_filter used when when scanning devices for lvmetad
  - cmd->filter used when processing lvmetad responses
  - cmd->full_fiilter (which is just cmd->lvmetad_filter + cmd->filter chained together) used
    for remaining situations

This patch adds the third one - "cmd->full_filter" - currently this is
used if device processing does not fall into any of the groups before,
for example, devices which does not have the PV label yet and we're just
creating a new one or we're processing the devices where the list of the
devices (PVs) is not returned by lvmetad initially.

Currently, the cmd->full_filter is used exactly in these functions:
  - lvmcache_label_scan
  - _pvcreate_check
  - pvcreate_vol
  - lvmdiskscan
  - pvscan
  - _process_each_label

If lvmetad is used, then simply cmd->full_filter == cmd->filter because
cmd->lvmetad_filter is NULL in this case.
2014-10-02 13:06:46 +02:00
Peter Rajnoha
a5f01dad22 filters: refresh filters when lvmetad use is toggled
We need to use proper filter chain when we disable lvmetad use
explicitly in the code by calling lvmetad_set_active(0) while
overriding existing configuration. We need to reinitialize filters
in this case so proper filter chain is used. The same applies
for the other way round - when we enable lvmetad use explicitly in
the code (though this is not yet used).
2014-09-30 16:08:05 +02:00
Peter Rajnoha
c2981cf921 filters: use usable device filter and separate lvmetad filter chain so it's not reevaluated for any lvmetad response
With this change, the filter chains used look like this now:

  A) When *lvmetad is not used*:
    - persistent filter -> regex filter -> sysfs filter ->
      global regex filter -> type filter ->
      usable device filter(FILTER_MODE_NO_LVMETAD) ->
      mpath component filter -> partitioned filter ->
      md component filter

  B) When *lvmetad is used* (two separate filter chains):
     - the lvmetad filter chain used when scanning devs for lvmetad update:
       sysfs filter -> global regex filter -> type filter ->
       usable device filter(FILTER_MODE_PRE_LVMETAD) ->
       mpath component filter -> partitioned filter ->
       md component filter

     - the filter chain used for lvmetad responses:
       persistent filter -> usable device filter(FILTER_MODE_POST_LVMETAD) ->
       regex filter
2014-09-30 13:22:11 +02:00
Peter Rajnoha
80ac8f37d6 filters: fix incorrect filter indexing in composite filter array
Caused by recent changes - a7be3b12df.
If global filter was not defined, then part of the code
creating composite filter (the cmd->lvmetad_filter) incorrectly
increased index value even if this global filter was not created
as part of the composite filter. This caused a gap with "NULL"
value in the composite filter array which ended up with the rest
of the filters after the gap to be ignored and also it caused a mem
leak when destroying the composite filter.
2014-09-11 09:30:03 +02:00
Petr Rockai
a7be3b12df lvmetad: Re-organise filters to properly avoid scans of component devices.
If a PV label is exposed both through a composite device (MD for example) and
through its component devices, we always want the PV that lvmetad sees to be the
composite, since this is what all LVM commands (including activation) will then
use. If pvscan --cache is triggered for multiple clones of the same PV, the last
to finish wins. This patch basically re-arranges the filters so that
component-device filters are part of the global_filter chain, not of the
client-side filter chain. This has a subtle effect on filter evaluation order,
but should not alter visible semantics in the non-lvmetad case.
2014-09-10 22:58:02 +01:00
Peter Rajnoha
d169ff1e03 conf: add report/list_item_separator lvm.conf option
For example:

$ lvm dumpconfig report/list_item_separator
list_item_separator=","

$ lvs -o name,tags vg/lvol1
  LV    LV Tags
  lvol1 a,x,y

$ lvm dumpconfig report/list_item_separator
list_item_separator=":"

$ lvs -o name,tags vg/lvol1
  LV    LV Tags
  lvol1 ay
2014-07-10 16:18:45 +02:00
Jonathan Brassow
be75076dfc activation: Add "degraded" activation mode
Currently, we have two modes of activation, an unnamed nominal mode
(which I will refer to as "complete") and "partial" mode.  The
"complete" mode requires that a volume group be 'complete' - that
is, no missing PVs.  If there are any missing PVs, no affected LVs
are allowed to activate - even RAID LVs which might be able to
tolerate a failure.  The "partial" mode allows anything to be
activated (or at least attempted).  If a non-redundant LV is
missing a portion of its addressable space due to a device failure,
it will be replaced with an error target.  RAID LVs will either
activate or fail to activate depending on how badly their
redundancy is compromised.

This patch adds a third option, "degraded" mode.  This mode can
be selected via the '--activationmode {complete|degraded|partial}'
option to lvchange/vgchange.  It can also be set in lvm.conf.
The "degraded" activation mode allows RAID LVs with a sufficient
level of redundancy to activate (e.g. a RAID5 LV with one device
failure, a RAID6 with two device failures, or RAID1 with n-1
failures).  RAID LVs with too many device failures are not allowed
to activate - nor are any non-redundant LVs that may have been
affected.  This patch also makes the "degraded" mode the default
activation mode.

The degraded activation mode does not yet work in a cluster.  A
new cluster lock flag (LCK_DEGRADED_MODE) will need to be created
to make that work.  Currently, there is limited space for this
extra flag and I am looking for possible solutions.  One possible
solution is to usurp LCK_CONVERT, as it is not used.  When the
locking_type is 3, the degraded mode flag simply gets dropped and
the old ("complete") behavior is exhibited.
2014-07-09 22:56:11 -05:00
Peter Rajnoha
da545ce3b4 tools: add --binary arg to pvs,vgs,lvs and {pv,vg,lv}display -C and report/binary_values_as_numeric lvm.conf option
The --binary option, if used, causes all the binary values reported
in reporting commands to be displayed as "0" or "1" instead of descriptive
literal values (value "unknown" is still used for values that could not be
determined).

Also, add report/binary_values_as_numeric lvm.conf option with the same
functionality as the --binary option (the --binary option prevails
if both --binary cmd option and report/binary_values_as_numeric lvm.conf
option is used at the same time). The report/binary_values_as_numeric is
also profilable.

This makes it easier to use and check lvm reporting command output in scripts.
2014-07-04 15:40:17 +02:00
Peter Rajnoha
3208396ce5 coverity: fix issues reported by coverity 2014-06-24 14:58:53 +02:00
Zdenek Kabelac
00af0d13c9 cleanup: more readable
Older gcc complained a bit about uninitialized vars
so reorder code for better readability.
2014-06-19 12:02:48 +02:00
Peter Rajnoha
5abdb52fdc report: select: refactor: move str_list to libdm
The list of strings is used quite frequently and we'd like to reuse
this simple structure for report selection support too. Make it part
of libdevmapper for general reuse throughout the code.

This also simplifies the LVM code a bit since we don't need to
include and manage lvm-types.h anymore (the string list was the
only structure defined there).
2014-06-17 16:27:20 +02:00
Peter Rajnoha
9e3e4d6994 config: differentiate command and metadata profiles and consolidate profile handling code
- When defining configuration source, the code now uses separate
  CONFIG_PROFILE_COMMAND and CONFIG_PROFILE_METADATA markers
  (before, it was just CONFIG_PROFILE that did not make the
  difference between the two). This helps when checking the
  configuration if it contains correct set of options which
  are all in either command-profilable or metadata-profilable
  group without mixing these groups together - so it's a firm
  distinction. The "command profile" can't contain
  "metadata profile" and vice versa! This is strictly checked
  and if the settings are mixed, such profile is rejected and
  it's not used. So in the end, the CONFIG_PROFILE_COMMAND
  set of options and CONFIG_PROFILE_METADATA are mutually exclusive
  sets.

- Marking configuration with one or the other marker will also
  determine the way these configuration sources are positioned
  in the configuration cascade which is now:

  CONFIG_STRING -> CONFIG_PROFILE_COMMAND -> CONFIG_PROFILE_METADATA -> CONFIG_FILE/CONFIG_MERGED_FILES

- Marking configuration with one or the other marker will also make
  it possible to issue a command context refresh (will be probably
  a part of a future patch) if needed for settings in global profile
  set. For settings in metadata profile set this is impossible since
  we can't refresh cmd context in the middle of reading VG/LV metadata
  and for each VG/LV separately because each VG/LV can have a different
  metadata profile assinged and it's not possible to change these
  settings at this level.

- When command profile is incorrect, it's rejected *and also* the
  command exits immediately - the profile *must* be correct for the
  command that was run with a profile to be executed. Before this
  patch, when the profile was found incorrect, there was just the
  warning message and the command continued without profile applied.
  But it's more correct to exit immediately in this case.

- When metadata profile is incorrect, we reject it during command
  runtime (as we know the profile name from metadata and not early
  from command line as it is in case of command profiles) and we
  *do continue* with the command as we're in the middle of operation.
  Also, the metadata profile is applied directly and on the fly on
  find_config_tree_* fn call and even if the metadata profile is
  found incorrect, we still need to return the non-profiled value
  as found in the other configuration provided or default value.
  To exit immediately even in this case, we'd need to refactor
  existing find_config_tree_* fns so they can return error. Currently,
  these fns return only config values (which end up with default
  values in the end if the config is not found).

- To check the profile validity before use to be sure it's correct,
  one can use :

    lvm dumpconfig --commandprofile/--metadataprofile ProfileName --validate

  (the --commandprofile/--metadataprofile for dumpconfig will come
   as part of the subsequent patch)

- This patch also adds a reference to --commandprofile and
  --metadataprofile in the cmd help string (which was missing before
  for the --profile for some commands). We do not mention --profile
  now as people should use --commandprofile or --metadataprofile
  directly. However, the --profile is still supported for backward
  compatibility and it's translated as:

    --profile == --metadataprofile for lvcreate, vgcreate, lvchange and vgchange
                 (as these commands are able to attach profile to metadata)

    --profile == --commandprofile for all the other commands
                (--metadataprofile is not allowed there as it makes no sense)

- This patch also contains some cleanups to make the code handling
  the profiles more readable...
2014-05-20 16:21:48 +02:00
Peter Rajnoha
9a324df3b3 config: fix incorrect profile initialization on cmd context refresh
When cmd refresh is called, we need to move any already loaded profiles
to profiles_to_load list which will cause their reload on subsequent
use. In addition to that, we need to take into account any change
in config/profile configuration setting on cmd context refresh
since this setting could be overriden with --config.

Also, when running commands in the shell, we need to remove the
global profile used from the configuration cascade so the profile
is not incorrectly reused next time when the --profile option is
not specified anymore for the next command in the shell.

This bug only affected profile specified by --profile cmd line
arg, not profiles referenced from LVM metadata.
2014-05-19 15:39:55 +02:00
Peter Rajnoha
c42f72867a config: attach cft_check_handle to each config tree instead of global cmd_context
Before, the cft_check_handle used to direct configuration checking
was part of cmd_context. It's better to attach this as part of the
exact config tree against which the check is done. This patch moves
the cft_check_handle out of cmd_context and it attaches it to the
config tree directly as dm_config_tree->custom->config_source->check_handle.

This change makes it easier to track the config tree check results
and provides less space for bugs as the results are directly attached
to the tree and we don't need to be cautious whether the global value
is correct or not (and whether it needs reinitialization) as it was
in the case when the cft_check_handle was part of cmd_context.
2014-05-19 15:38:04 +02:00
Peter Rajnoha
4360fdf89c libdevmapper: add dm_units_to_factor for size unit parsing
Actually moving the existing code from LVM to libdm for reuse.
2014-04-28 10:25:43 +02:00
Zdenek Kabelac
559c003ee2 cleanup: reduce inclusion of unnecessary headers
Remove those file which are not needed by .c files
or already include because the headers already needs them.
2014-04-18 16:38:50 +02:00
Alasdair G Kergon
b5f8f452ac tools: Add --readonly support.
Offer lock-free access to display virtual machine or clustered VG metadata
while it might be in use.
2014-04-18 02:46:34 +01:00
Zdenek Kabelac
13258d6e96 debug: add proper backtrace debug
When failure happens inside refresh, print proper debug backtrace.
2014-03-25 11:22:59 +01:00
Zdenek Kabelac
68d13b2517 dev-cache: fix mem corruption on refresh context
When lvm2 command works with clvmd and uses locking in wrong way,
it may 'leak' certain file descriptors in opened (incorrect) state.

dev_cache_exit then destroys memory pool of cached devices, while
_open_devices list in dev-io.c was still referencing them if they
were still opened.

Patch properly calls _close() function to 'self-heal' from this
invalid state, but it will report internal error (so execution
with abort_on_internal_error causes immediate death). On the
normal 'execution', error is only reported, but memory state is
corrected, and linked list is not referencing devices from
released mempool.

For crash see: https://bugzilla.redhat.com/show_bug.cgi?id=1073886
2014-03-25 11:22:57 +01:00
Zdenek Kabelac
fc280bcc42 lvmcache: handle reinit without error
Since commit f12ee43f2e call destroy,
it start to check all VGs are unlocked. However when we become_daemon,
we simply reset locking (since lock is still kept by parent process).
So implement a simple 'reset' flag.
2014-03-21 22:29:21 +01:00
Peter Rajnoha
000e81a999 cleanup: add cmd_context reference to struct cft_check_handle
So we have all things needed to do a configuration check packaged
in one handle. It makes function calls inside a bit more readable.
2014-03-19 08:45:05 +01:00
Peter Rajnoha
927784cd06 config: make global/suffix profilable and add it to lvm.conf
The global/suffix was missing from example lvm.conf but it can
be very useful when using lvm in scripts and now in profiles as well
Let's expose it more.
2014-03-18 09:24:17 +01:00
Peter Rajnoha
c1ce2cc86c config: make global/units and global/si_unit_consistency profilable 2014-03-17 16:07:29 +01:00
Peter Rajnoha
11039589d3 config: runtime default for config/profile_dir
The config/profile_dir default value takes LVM_SYSTEM_DIR into consideraton.
2014-03-06 11:16:04 +01:00
Peter Rajnoha
0da1e5d9f8 config: runtime default for backup/backup_dir, backup/archive_dir
The backup/backup_dir and backup/archive_dir default value is evaluated
in runtime and takes LVM_SYSTEM_DIR into consideration...
2014-03-06 11:15:21 +01:00
Peter Rajnoha
f6adef9825 config: runtime default for devices/cache, devices/cache_dir
The devices/cache and devices/cache_dir are evaluated in runtime this way:

  - if devices/cache is set, use it

  - if devices_cache/dir or devices/cache_file_prefix is set, make up a
    path out of that for devices/cache in runtime, taking into account
    the LVM_SYSTEM_DIR environment variable if set

  - otherwise make up the path out of default which is:
    <LVM_SYSTEM_DIR>/<cache_dir>/<cache_file_prefix>.cache

With the runtime defaults, we can encode this easily now. Also, the lvm
dumpconfig can show proper and exact information about this setting then
(the variant that shows default values).
2014-03-06 11:07:54 +01:00