IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
There are currently a few issues with the reporting done on RAID LVs and
sub-LVs. The most concerning is that 'lvs' does not always report the
correct failure status of individual RAID sub-LVs (devices). This can
occur when a device fails and is restored after the failure has been
detected by the kernel. In this case, 'lvs' would report all devices are
fine because it can read the labels on each device just fine.
Example:
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 100.00 lv_rimage_0(0),lv_rimage_1(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
However, 'dmsetup status' on the device tells us a different story:
[root@bp-01 lvm2]# dmsetup status vg-lv
0 1024000 raid raid1 2 DA 1024000/1024000
In this case, we must also be sure to check the RAID LVs kernel status
in order to get the proper information. Here is an example of the correct
output that is displayed after this patch is applied:
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-p 100.00 lv_rimage_0(0),lv_rimage_1(0)
[lv_rimage_0] vg iwi-aor-p /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rmeta_0] vg ewi-aor-p /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
The other case where 'lvs' gives incomplete or improper output is when a
device is replaced or added to a RAID LV. It should display that the RAID
LV is in the process of sync'ing and that the new device is the only one
that is not-in-sync - as indicated by a leading 'I' in the Attr column.
(Remember that 'i' indicates an (i)mage that is in-sync and 'I' indicates
an (I)mage that is not in sync.) Here's an example of the old incorrect
behaviour:
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 100.00 lv_rimage_0(0),lv_rimage_1(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
[root@bp-01 lvm2]# lvconvert -m +1 vg/lv; lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 0.00 lv_rimage_0(0),lv_rimage_1(0),lv_rimage_2(0)
[lv_rimage_0] vg Iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg Iwi-aor-- /dev/sdb1(1)
[lv_rimage_2] vg Iwi-aor-- /dev/sdc1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
[lv_rmeta_2] vg ewi-aor-- /dev/sdc1(0) ** Note that all the images currently are marked as 'I' even though it is
only the last device that has been added that should be marked.
Here is an example of the correct output after this patch is applied:
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 100.00 lv_rimage_0(0),lv_rimage_1(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
[root@bp-01 lvm2]# lvconvert -m +1 vg/lv; lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg rwi-a-r-- 0.00 lv_rimage_0(0),lv_rimage_1(0),lv_rimage_2(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg iwi-aor-- /dev/sdb1(1)
[lv_rimage_2] vg Iwi-aor-- /dev/sdc1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-- /dev/sdb1(0)
[lv_rmeta_2] vg ewi-aor-- /dev/sdc1(0)
** Note only the last image is marked with an 'I'. This is correct and we can
tell that it isn't the whole array that is sync'ing, but just the new
device.
It also works under snapshots...
[root@bp-01 lvm2]# lvs -a -o name,vg_name,attr,copy_percent,devices vg
LV VG Attr Cpy%Sync Devices
lv vg owi-a-r-p 33.47 lv_rimage_0(0),lv_rimage_1(0),lv_rimage_2(0)
[lv_rimage_0] vg iwi-aor-- /dev/sda1(1)
[lv_rimage_1] vg Iwi-aor-p /dev/sdb1(1)
[lv_rimage_2] vg Iwi-aor-- /dev/sdc1(1)
[lv_rmeta_0] vg ewi-aor-- /dev/sda1(0)
[lv_rmeta_1] vg ewi-aor-p /dev/sdb1(0)
[lv_rmeta_2] vg ewi-aor-- /dev/sdc1(0)
snap vg swi-a-s-- /dev/sda1(51201)
We can avoid many dev_manager (ioctl) calls by caching the results of
previous calls to lv_raid_dev_health. Just considering the case where
'lvs -a' is called to get the attributes of a RAID LV and its sub-lvs,
this function would be called many times. (It would be called at least
7 times for a 3-way RAID1 - once for the health of each sub-LV and once
for the health of the top-level LV.) This is a good idea because the
sub-LVs are processed in groups along with their parent RAID LV and in
each case, it is the parent LV whose status will be queried. Therefore,
there only needs to be one trip through dev_manager for each time the
group is processed.
Similar to the way thin* accesses its kernel status, we add a method
for RAID to grab the various values in its status output without the
higher levels (LVM) having to understand how to parse the output.
Added functions include:
- lib/activate/dev_manager.c:dev_manager_raid_status()
Pulls the status line from the kernel
- libdm/libdm-deptree.c:dm_get_status_raid()
Parses status line and puts components into dm_status_raid struct
- lib/activate/activate.c:lv_raid_dev_health()
Accesses dm_status_raid to deliver raid dev_health string
The new structure and functions can provide a more unified way to access
status information. ('lv_raid_percent' could switch to using these
functions, for example.)
Fix this:
pvcreate /dev/scma
Device /dev/scma not found (or ignored by filtering).
Reported-by: Peter Oberparleiter <peter.oberparleiter@de.ibm.com>
Signed-off-by: Sebastian Ott <sebott@linux.vnet.ibm.com>
Add log/debug_classes to lvm.conf to allow debug messages to be
classified and filtered at runtime.
The dm_errno field is only used by log_error(), so I've redefined it
for log_debug() messages to hold the message class.
By default, all existing messages appear, but we can add categories that
generate high volumes of data, such as logging all traffic to/from
lvmetad.
fmt1 doesn't have a separate commit function: updates take effect
immediately vg_write is called, so we must update lvmetad at this
point if we're going to go on and ask lvmetad for the VG metadata
again before calling the commit function (though that's probably an
unsupported and pointless thing to do anyway as the client must
already have that data and it cannot have changed because it's locked
and with devs suspended we shouldn't be communicating with lvmetad;
so when that's fixed properly, this fix here can be reverted).
This problem showed up as an internal error when lvremoving an LVM1
snapshot.
> Internal error: LV snap1 (00000000000000000000000000000001) missing from preload metadata
https://bugzilla.redhat.com/891855
Rename lvmetad_warning() to lvmetad_connect_or_warn().
Log all connection attempts on the client side, whether successful or not.
Reduce some nesting and remove a redundant assertion.
If a RAID array is not in-sync, replacing devices should not be allowed
as a general rule. This is because the contents used to populate the
incoming device may be undefined because the devices being read where
not in-sync. The kernel enforces this rule unless overridden by not
allowing the creation of an array that is not in-sync and includes a
devices that needs to be rebuilt.
Since we cannot know the sync state of an LV if it is inactive, we must
also enforce the rule that an array must be active to replace devices.
That leaves us with the following conditions:
1) never allow replacement or repair of devices if the LV is in-active
2) never allow replacement if the LV is not in-sync
3) allow repair if the LV is not in-sync, but warn that contents may
not be recoverable.
In the case where a user is performing the repair on the command line via
'lvconvert --repair', the warning is printed before the user is prompted
if they would like to replace the device(s). If the repair is automated
(i.e. via dmeventd and policy is "allocate"), then the device is replaced
if possible and the warning is printed.
If the lvmcache_info_from_pvid() fails to find valid
info, invoke the lookup by dev, and only in this case
call lvmcache_info_from_pvid() again.
Also check for the result of info and return
error directly, so the NULL is not passed
to lvmcache_get_label().
When the abort_on_internal_errors is enabled, we aborted prior
the syslog logging output.
Since such fatal error gets level _LOG_FATAL it should
not be blocked by debug_level() check so lets move it further,
to get abort error logged also via syslog.
Calling pvscan --cache with -aay on a PV without an MDA would spuriously fail
with an internal error, because of an incorrect assumption that a parsed VG
structure was always available. This is not true and the autoactivation handler
needs to call vg_read to obtain metadata in cases where the PV had no MDAs to
parse. Therefore, we pass vgid into the handler instead of the (possibly NULL)
VG coming from the PV's MDA.
Arghh, this was bad last-minute shortening of if() expression
in the commit 1ef9831018.
dm_tree_node_set_thin_pool_discard() must not run in the same
expression as check for non-power-2 discard, otherwise
there are 2 calls for dm_tree_node_set_thin_pool_discard
and whole setting of discards is missinterpretted.
In-relase fix it by using proper parentheses {}.
Function _ignore_blocked_mirror_devices was not release
allocated strings images_health and log_health.
In error paths it was also not releasing dm_task structure.
Swaped return code of _ignore_blocked_mirror_devices and
use 1 as success.
In _parse_mirror_status use log_error if memory allocation
fails and few more errors so they are no going unnoticed
as debug messages.
On error path always clear return values and free strings.
For dev_create_file use cache mem pool to avoid memleak.
In case we don't want to activate, autoactivate or have the
VG/LV read-only. Primarily targeted for the auto_activation_volume_list,
but it makes no harm for other settings (the part of the code
that reads these three settings is shared, but there's no
reason to separate it only for this change).
Rework thin feature detection to support runtime
section to allow to disable them selectively.
New lvm.conf option is born: global/thin_disabled_features
$ export DM_DISABLE_UDEV=1
$ dmsetup create test --table "0 1 zero"
Udev is running and DM_DISABLE_UDEV environment variable is set. Bypassing udev, device-mapper library will manage device nodes in device directory.
$ lvchange -ay vg/lvol0
Udev is running and DM_DISABLE_UDEV environment variable is set. Bypassing udev, LVM will manage logical volume symlinks in device directory.
Udev is running and DM_DISABLE_UDEV environment variable is set. Bypassing udev, LVM will obtain device list by scanning device directory.
Udev is running and DM_DISABLE_UDEV environment variable is set. Bypassing udev, device-mapper library will manage device nodes in device directory.
Setting this environment variable will cause a full fallback
to old direct node and symlink management in libdevmapper and lvm2.
It means:
- disabling udev synchronization
(--noudevsync in dmsetup and --noudevsync + activation/udev_sync=0
lvm2 config)
- disabling dm and any subsystem related udev rules
(--noudevrules in dmsetup and activation/udev_rules=0 lvm2 config)
- management of nodes/symlinks under /dev directly by libdevmapper/lvm2
(--verifyudev in dmsetup and activation/verify_udev_operations=1
lvm2 config)
- not obtaining any device list from udev database
(devices/obtain_device_list_from_udev=0 lvm2 config)
Note: we could set all of these before - there's no functional change!
However the DM_DISABLE_UDEV environment variable is a nice shortcut
to make it easier for libdevmapper users so that one can switch off all
of the udev management off at one go directly on the command line,
without a need to modify any source or add any extra switches.
Allow restoring metadata with thin pool volumes.
No validation is done for this case within vgcfgrestore tool -
thus incorrect metadata may lead to destruction of pool content.
Configurable settings for thin pool create
if they are not specified on command line.
New supported lvm.conf options are:
allocation/thin_pool_chunk_size
allocation/thin_pool_discards
allocation/thin_pool_zero
Check if target supports discards for chunk sizes,
that are not power of 2 (just multiple of 64K),
and enable it in case it's supported by thin kernel target.
Commit bf2741376d started to use
lv_is_active() instead of call for lv_info & info.exists so
we cover also cluster activated devices.
For snapshost the conversion was not correct and introduced
regression by blocking creation of snapshot of inactive LV.
Fix it by assigning lv_is_active() directly.
Note: we still have minor issue to fix - to make
lv_is_???? function able to return error states since
lv_info() may fail.
Target tells us its version, and we may allow different set of options
to be supported with different version of driver.
Idea is to provide individual feature flags and later be
able to query for them.
Commit 9fd7ac7d03 did not handle mirrors
that contained mirrored logs. This is because the status line of the
mirror does not give an indication of the health of the mirrored log,
as you can see here:
[root@bp-01 lvm2]# dmsetup status vg-lv vg-lv_mlog
vg-lv: 0 409600 mirror 2 253:6 253:7 400/400 1 AA 3 disk 253:5 A
vg-lv_mlog: 0 8192 mirror 2 253:3 253:4 7/8 1 AD 1 core
Thus, the possibility for LVM commands to hang still persists when mirror
have mirrored logs. I discovered this while performing some testing that
does polling with 'pvs' while doing I/O and killing devices. The 'pvs'
managed to get between the mirrored log device failure and the attempt
by dmeventd to repair it. The result was a very nasty block in LVM
commands that is very difficult to remove - even for someone who knows
what is going on. Thus, it is absolutely essential that the log of a
mirror be recursively checked for mirror devices which may be failed
as well.
Despite what the code comment says in the aforementioned commit...
+ * _mirrored_transient_status(). FIXME: It is unable to handle mirrors
+ * with mirrored logs because it does not have a way to get the status of
+ * the mirror that forms the log, which could be blocked.
... it is possible to get the status of the log because the log device
major/minor is given to us by the status output of the top-level mirror.
We can use that to query the log device for any DM status and see if it
is a mirror that needs to be bypassed. This patch does just that and is
now able to avoid reading from mirrors that have failed devices in a
mirrored log.
Addresses: rhbz855398 (Allow VGs to be built on cluster mirrors),
and other issues.
The LVM code attempts to avoid reading labels from devices that are
suspended to try to avoid situations that may cause the commands to
block indefinitely. When scanning devices, 'ignore_suspended_devices'
can be set so the code (lib/activate/dev_manager.c:device_is_usable())
checks any DM devices it finds and avoids them if they are suspended.
The mirror target has an additional mechanism that can cause I/O to
be blocked. If a device in a mirror fails, all I/O will be blocked
by the kernel until a new table (a linear target or a mirror with
replacement devices) is loaded. The mirror indicates that this condition
has happened by marking a 'D' for the faulty device in its status
output. This condition must also be checked by 'device_is_usable()' to
avoid the possibility of blocking LVM commands indefinitely due to an
attempt to read the blocked mirror for labels.
Until now, mirrors were avoided if the 'ignore_suspended_devices'
condition was set. This check seemed to suggest, "if we are concerned
about suspended devices, then let's ignore mirrors altogether just
in case". This is insufficient and doesn't solve any problems. All
devices that are suspended are already avoided if
'ignore_suspended_devices' is set; and if a mirror is blocking because
of an error condition, it will block the LVM command regardless of the
setting of that variable.
Rather than avoiding mirrors whenever 'ignore_suspended_devices' is
set, this patch causes mirrors to be avoided whenever they are blocking
due to an error. (As mentioned above, the case where a DM device is
suspended is already covered.) This solves a number of issues that weren't
handled before. For example, pvcreate (or any command that does a
pv_read or vg_read, which eventually call device_is_usable()) will be
protected from blocked mirrors regardless of how
'ignore_suspended_devices' is set. Additionally, a mirror that is
neither suspended nor blocking is /allowed/ to be read regardless
of how 'ignore_suspended_devices' is set. (The latter point being the
source of the fix for rhbz855398.)
The heading 'Copy%' is specific to PVMOVE volumes, but can be generalized
to apply to LVM mirrors also. It is a bit awkward to use 'Copy%' for
RAID 4/5/6, however - 'Sync%' would be more appropriate. This is why
RAID 4/5/6 have not displayed their sync status by any means available to
'lvs' yet.
Example (old):
[root@hayes-02 lvm2]# lvs vg
LV VG Attr LSize Pool Origin Data% Move Log Cpy%Sy Convert
lv vg -wi-a---- 1.00g
raid1 vg rwi-a-r-- 1.00g 100.00
raid4 vg rwi-a-r-- 1.01g
raid5 vg rwi-a-r-- 1.01g
raid6 vg rwi-a-r-- 1.01g
This patch changes the heading to 'Cpy%Sync' and allows RAID 4/5/6 to print
their sync percent in this field.
Example (new):
[root@hayes-02 lvm2]# lvs vg
LV VG Attr LSize Pool Origin Data% Move Log Cpy%Sync Convert
lv vg -wi-a---- 1.00g
raid1 vg rwi-a-r-- 1.00g 100.00
raid4 vg rwi-a-r-- 1.01g 100.00
raid5 vg rwi-a-r-- 1.01g 100.00
raid6 vg rwi-a-r-- 1.01g 100.00
The 'copy_percent' function takes the 'extents_copied' field from each
segment in an LV to create the numerator for the ratio that is to
become the copy_percent. (Otherwise known as the 'sync' percent for
non-pvmove uses, like mirror LVs and RAID LVs.) This function safely
works on RAID - not just mirrors - so it is better to have it in
lv_manip.c rather than mirror.c.
There's a lot of different functions that do a lot of different things
in lv_manip.c, so I placed the function near a function in lv_manip.c
that it was close to in metadata-exported.h. Different placement in the
file or a different name for the function may be useful.
Use log_warn to print non-fatal warning messages.
Use of log_error would confuse checker for testing
whether proper error has been reported for some real error.
A message is printed when the region_size of a RAID LV is adjusted
to allow for large (> ~1TB) LVs. The message wasn't very clear.
Hopefully, this is better.
When valgrind usage is desired by user (--enable-valgrind-pool)
skip playing/closing/reopenning with descriptors - it makes
valgridng useless.
Make sleep delay for clvmd start longer.
Use configure --enable-python_bindings to generate them.
Note that the Makefiles do not yet control the owner or permissions of
the two new files on installation.
It would be possible to activate a RAID LV exclusively in a cluster
volume group, but for now we do not allow RAID LVs to exist in a
clustered volume group at all. This has two components:
1) Do not allow RAID LVs to be created in a clustered VG
2) Do not allow changing a VG from single-machine to clustered
if there are RAID LVs present.
MD's bitmaps can handle 2^21 regions at most. The RAID code has always
used a region_size of 1024 sectors. That means the size of a RAID LV was
limited to 1TiB. (The user can adjust the region_size when creating a
RAID LV, which can affect the maximum size.) Thus, creating, extending or
converting to a RAID LV greater than 1TiB would result in a failure to
load the new device-mapper table.
Again, the size of the RAID LV is not limited by how much space is allocated
for the metadata area, but by the limitations of the MD bitmap. Therefore,
we must adjust the 'region_size' to ensure that the number of regions does
not exceed the limit. I've added code to do this when extending a RAID LV
(which covers 'create' and 'extend' operations) and when up-converting -
specifically from linear to RAID1.
We were using daemon_send_simple until now, but it is no longer adequate, since
we need to manipulate requests in a generic way (adding a validity token to each
request), and the tree-based request interface is much more suitable for this.
- move common dm_config_tree manipulation functions from lvmetad-core to
daemon-shared
- add config-tree-based request manipulation APIs to daemon-client
- factor out _v (va_list) variants of most variadic functions in libdaemon
Don't try to issue discards to a missing PV to avoid segfault.
Prevent lvremove from removing LVs that have any part missing.
https://bugzilla.redhat.com/857554
Failing to clear the LV_NOTSYNCED flag when converting a RAID1 LV to
linear can result in the flag being present after an upconvert - even
if the sync is performed when upconverting.
Mirrors do not allow upconverting if the LV has been created with --nosync.
We will enforce the same rule for RAID1. It isn't hugely critical, since
the portions that have been written will be copied over to the new device
identically from either of the existing images. However, the unwritten
sections may be different, causing the added image to be a hybrid of the
existing images.
Also, we are disallowing the addition of new images to a RAID1 LV that has
not completed the initial sync. This may be different from mirroring, but
that is due to the fact that the 'mirror' segment type "stacks" when adding
a new image and RAID1 does not. RAID1 will rebuild a newly added image
"inline" from the existant images, so they should be in-sync.
We cannot add images to a RAID array while it is not in-sync. The
kernel will simply reject the table, saying:
'rebuild' specified while array is not in-sync
Now we check to ensure the LV is in-sync before attempting image
additions.
It is necessary when creating a RAID LV to clear the new metadata areas.
Failure to do so could result in a prepopulated bitmap that would cause
the new array to skip syncing portions of the array. It is a requirement
that the metadata LVs be activated and cleared in the process of creating.
However in test mode, this requirement should be lifted - no new LVs should
be created or written to.
When printing a message for the user and the lv_segment pointer is available,
use segtype->ops->name() instead of segtype->name. This gives a better
user-readable name for the segment. This is especially true for the
'striped' segment type, which prints "linear" if there is an area_count of
one.
We should check whether the fd is opened before trying to reopen it.
For example, the stdin is closed in test/lib/harness.c causing the
test suite to fail.
Fix setvbuf code by closing and reopening stream before changing buffer.
But we need to review what this code is doing embedded inside a library
function rather than the simpler original form being run independently
at the top of main() by tools that need it.
Accept -q as the short form of --quiet.
Suppress non-essential standard output if -q is given twice.
Treat log/silent in lvm.conf as equivalent to -qq.
Review all log_print messages and change some to
log_print_unless_silent.
When silent, the following commands still produce output:
dumpconfig, lvdisplay, lvmdiskscan, lvs, pvck, pvdisplay,
pvs, version, vgcfgrestore -l, vgdisplay, vgs.
[Needs checking.]
Non-essential messages are shifted from log level 4 to log level 5
for syslog and lvm2_log_fn purposes.
This patch adds support for RAID10. It is not the default at this
stage. The user needs to specify '--type raid10' if they would like
RAID10 instead of stacked mirror over stripe.
Adding couple INTERNAL_ERROR reports for unwanted parameters:
Ensure the 'top' metadata node cannot be NULL for lvmetad.
Make obvious vginfo2 cannot be NULL.
Report internal error if handler and vg is undefined.
Check for handle in poll_vg().
Ensure seg is not NULL in dev_manager_transient().
Report missing read_ahead for _lv_read_ahead_single().
Check for report handler in dm_report_object().
Check missing VG in _vgreduce_single().
Always store discard setting in LV metadata. (Note that lvcreate_params
doesn't yet use --discard to set the initial value.)
Remove undocumented env var LVM_THIN_VERSION_MIN that has no use on a
live system.
Change verbose 'feature not found' messages to debug.
Use discard_str for string value of discard.
I think it's better not to abbreviate human-readable fields like
'discard' to a single character. Users can truncate it to the
first character themselves if they wish.
It's confusing to use the variable name discard for different things in
different places - use discard_str when it's a string not the enum.
Respond with "unknown" rather than a NULL pointer if there's an
internal error and the discard value is invalid.
Don't accept 'no_passdown' or 'no-passdown' variants in the LVM
metadata: this is written by the program so should only ever contain
"nopassdown" and should be validated strictly against that.
Commit 8767435ef8 allowed RAID 4/5/6
LV to be extended properly, but introduced a regression in device
replacement - a critical component of fault tolerance.
When only 1 or 2 drives are being replaced, the 'area_count' needed
can be equal to the parity_count. The 'area_multiple' for RAID 4/5/6
was computed as 'area_count - parity_devs', which could result in
'area_multiple' being 0. This would ultimately lead to a division by
zero error. Therefore, in calc_area_multiple, it is important to take
into account the number of areas that are being requested - just as
we already do in _alloc_init.
A regression introduced in 2.02.89 (11e520256b)
caused the lvm dumpconfig <node> to print out
the node as well as its subsequent siblings.
The information about "only_one" mode got lost.
Before this patch (just an example node):
# lvm dumpconfig global/use_lvmetad
use_lvmetad=1
thin_check_executable="/usr/sbin/thin_check"
thin_check_options="-q"
(...all nodes to the end of the section)
With this patch applied:
# lvm dumpconfig global/use_lvmetad
use_lvmetad=1
Add arg support for discard.
Add discard ignore, nopassdown, passdown (=default) support.
Flags could be set per pool.
lvcreate [--discard {ignore|no_passdown|passdown}] vg/thinlv
Reducing a RAID 4/5/6 LV or extending it with a different number of
stripes is still not implemented. This patch covers the "simple" case
where the LV is extended with the same number of stripes as the orginal.
Change 'lv_passes_volumes_filter' fn back to static as it's not
actually needed in the other code (a remnant from devel version).
Fix lvm.conf comment referencing '--autoactivate' which was finally
decided to be '--activate ay'.
If _alloc_parallel_area for raid devices chooses an area already used
up, it doesn't notice that it has no space left in it and leaves
later code trying to place a zero-length area into the LV.
https://bugzilla.redhat.com/832596
One can use "lvcreate --aay" to have the newly created volume
activated or not activated based on the activation/auto_activation_volume_list
this way.
Note: -Z/--zero is not compatible with -aay, zeroing is not used in this case!
When using lvcreate -aay, a default warning message is also issued that zeroing
is not done.
Define an 'activation_handler' that gets called automatically on
PV appearance/disappearance while processing the lvmetad_pv_found
and lvmetad_pv_gone functions that are supposed to update the
lvmetad state based on PV availability state. For now, the actual
support is for PV appearance only, leaving room for PV disappearance
support as well (which is a more complex problem to solve as this
needs to count with possible device stack).
Add a new activation change mode - CHANGE_AAY exposed as
'--activate ay/-aay' argument ('activate automatically').
Factor out the vgchange activation functionality for use in other
tools (like pvscan...).
We're refererring to 'activation' all over the code and we're talking
about 'LVs being activated' all the time so let's use 'activation/activate'
everywhere for clarity and consistency (still providing the old
'available' keyword as a synonym for backward compatibility with
existing environments).
Update release_lv_segment_area not to discard any PV extents,
as it also gets used when moving extents between LVs.
Instead, call a new function release_and_discard_lv_segment_area() in
the two places where data should be discarded - lv_reduce() and
remove_mirrors_from_segments().
There were several hard-coded values for run directory around the code.
Also, some tools are DM specific only, others are LVM specific and there
was no distinction made here before. With this patch applied, we have
this cleaned up a bit (subsystem in brackets, defaults in parentheses):
[common] configurable PID_DIR (/var/run)
lvm [lvm] configurable RUN_DIR (/var/run/lvm)
configurable locking dir (/var/lock/lvm)
clvmd [lvm] configurable pid file (PID_DIR/clvmd.pid)
socket (RUN_DIR/clvmd.sock)
lvmetad [lvm] configurable pid file (PID_DIR/lvmetad.pid)
socket (RUN_DIR/lvmetad.socket)
dm [dm] configurable DM_RUN_DIR (/var/run)
cmirrord [dm] configurable pid file (PID_DIR/cmirrord.pid)
dmeventd [dm] configurable pid file (PID_DIR/dmeventd.pid)
server fifo (DM_RUN_DIR/dmeventd-server)
client fifo (DM_RUN_DIR/dmeventd-client)
The changes briefly:
- added configure --with-default-pid-dir
- added configure --with-default-dm-run-dir
- added configure --with-lvmetad-pidfile
- by default, using one common pid directory for everything
(only lvmetad was not following this before)
There's no need to have the device open RW while obtaining the readahead value.
The RW open used before caused the CHANGE udev event to be generated if the
WATCH udev rule was set for the underlying device (and that is normally the
case both for non-dm and dm devices by default).
This did not cause any problems before since we were not interested in
*underlying* devices. However, with upcoming changes (autoactivation), we're
watching for events on underlying devices marked as PVs and such a spurious
event could cause the autoactivation code to be triggered. So when trying
to deactivate the volume, we could end up with immediate activation just after
that because of the CHANGE event originated in the WATCH udev rule since the
underlying device was open RW during the deactivation process.
Though maybe a better solution would be to completely filter such spurious
events out of the autoactivation process somehow, it's still useful if there
are as least spurious events generated as possible in the system itself.
If the user would set bigger reserved stack size then what
is allowed in resources (ulimit -s), then he would get coredump
So avoid coredump and ignore creation of such large stack size
(lvm should work properly, with just 64KB, so the option could
be eliminated).
If the user specifies number in the range of [4G/1024, 4G>,
the used value would wrap around (32bit math).
So keep the math 64bit.
Note, using such large lvm.conf values is pointless with lvm2.
With latest changes in the udev, some deprecated functions were removed
from libudev amongst which there was the "udev_get_dev_path" function
we used to compare a device directory used in udev and directore set in
libdevmapper. The "/dev" is hardcoded in udev now (udev version >= 183).
Amongst other changes and from packager's point of view, it's also
important to note that the libudev development library ("libudev-devel")
could now be a part of the systemd development library ("systemd-devel")
because of the udev + systemd merge.
When mirrors are up-converted, a transient mirror layer is put in so that
only the new devices are sync'ed. That transient layer must carry the tags
of the original mirror LV, otherwise it will fail to activate when activation
is regulated by lvm.conf:activation/volume_list. The conversion would then
fail.
The fix is to do exactly the same thing that is being done for linear ->
mirror converting (lib/metadata/mirror.c:_init_mirror_log()). We copy the
tags temporarily for the new LV and remove them after the activation.
Snapshots of RAID logical volumes are allowed (including "raid1"). However,
snapshots of "mirror" logical volumes has been disallowed due to unsolvable
issues inherent to the design. The fact that mirroring (dm-raid1.c) must
stop all I/O as the result of a failure and wait for userspace intervention
can lead to a circular dependency if userspace is simultaneously waiting for
snapshots (on mirrors) to make an I/O update before proceeding.
Various snapshot on mirror tests have been removed as a result.
If two devices in an array failed, it was previously impossible to replace
just one of them. This patch allows for the replacement of some, but perhaps
not all, failed devices.
The 'mirror' segtype and 'raid1' segtype both set the 'MIRRORED' flag.
However, due to differences in the way these device-mapper targets behave
'mirror' must be suspended with the 'noflush' option and 'raid1' does not
have to be.
This patch ensures that when the 'MIRRORED' flag is checked to see if
'noflush' is needed that it does not also set it for 'raid1' by mistake.
The logic for resuming the original and newly split LVs was not properly
done to handle situations where anything but the last device in the array
was split. It did not take into account the possible name collisions that
might occur when the original LV undergoes the shifting and renaming of its
sub-LVs.
Libudev does not provide transactions when querying udev database - once we
get the list of block devices (devices/obtain_device_list_from_udev=1) and
we iterate over the list to get more detailed information about device node
and symlink names used etc., the device could be removed just in between we
get the list and put a query for more info. In this case, libudev returns
NULL value as the device does not exist anymore.
Recently, we've added a warning message to reveal such situations. However,
this could be misleading if the device is not related to the LVM action
we're just processing - the non-related block device could be removed in
parallel and this is not an error but a possible and normal operation.
(N.B. This "missing info" should not happen when devices are related to
the LVM action we're just processing since all such processing should be
synchronized with udev and the udev db must always be in consistent state
after the sync point. But we can't filter this situation out from others,
non-related devices, so we have to lower the message verbosity here for a
general solution.)
Activation on remote node should be tried only if it is masked by tags
locally (like when hosttags enabled, IOW activate_lv_excl_local()
doesn't return error.)
Introduced change caused that lvchange -aey succeeded even if volume was
activated exclusively remotely.
In this case we should allow to use local mirror, check for cmirror
should apply only for lvconvert/lvcreate.
Introduced in 2.02.86 by removing !(lv->status & ACTIVATE_EXCL).
(Partially workaround, it is minimalistic patch for now.)
Code adds better support for monitoring of thin pool devices.
update_pool_lv uses DMEVENTD_MONITOR_IGNORE to not manipulate with monitoring.
vgchange & lvchange are checking real thin pool device for existance
as we are using _tpool real device and visible LV pool device might not
be even active (_tpool is activated implicitely for any thin volume).
monitor_dev_for_events is another _lv_postorder like code it might be worth
to think about reusing it here - for now update the code to properly
monitory thin volume deps.
For unmonitoring add extra code to check the usage of thin pool - in case it's in use
unmonitoring of thin volume is skipped.
There are kernel drivers (smblk) which set '-1' as their device major number.
This number is listed in /proc/devices then - but the kernel itself is using
just 12 bits - thus device is accessible via 4095 - there is posted patch
for 3.4 to fix this behavior (0 for auto allocation was mean to be used).
However to still allow using such devices with older kernels add some code
to use same behavior - so cut 12 bits from the major number from /proc/devices.
For now use log_warn() - maybe the severity of the message could be lowered
to just verbose level.
When down-converting a RAID1 device, it is the last device that is extracted
and removed when the user does not specify a particular device. However,
when a device is specified (and it is not the last), the device is removed and
the remaining sub-LVs are "shifted down" to fill the hole. This cause problems
when resuming the LV because if the shifted devices were resumed (and thus
renamed) before the sub-LV being extracted, there would be a name conflict.
The solution is to resume the extracted sub-LVs first so that they can be
properly renamed preventing a possible conflict.
This addresses bug 801967.
Update a way we handle option passing - so we now support path and options
with space inside.
Fix dm name usage for thin pools with '-' in name.
Use new lvm.conf option thin_check_options to pass in options as string array.
Save some relocation entries and use directly char[].
Since we do not need yes more then 127 partitions per device, use just int8_t.
Move lvm_type_filter_destroy into local static function.
Never return unfinished toolcontext - since error path is hit on
various stages of initialization we cannot leave it partially uninitialized,
since we would need to spread many more test across the code for config_valid.
Instead return NULL and properly release udev library resources as well.
If the lvcreate may decide some automagical values for a user,
try to keep the pool metadata size into 128MB range for optimal
perfomance (as suggested by Joe).
So if the pool metadata size and chunk_size were not specified,
try to select such values they would fit into 128MB size.
Use thin_dump --repair suggestion in log error message
and use just warning on deactivation path without repair info
(since node has been deactivated).
Also check whether there is not 16 args for thin_check configured.
Avoid using NULL pointers from udev. It seems like some older versions of udev
were improperly returning NULL in some case, so do not silently break here,
and give at least a warning to the user.
Use libdm callback to execute thin_check before activation
thin pool and after deactivation as well.
Supporting thin_check_executable which may pass in extra options for
the tool.
Add 3rd daemon return state "unknown" for lookups that are carried out
successfully but don't find the item requested.
Avoid issuing error messages when it's expected that a device that's
being looked up in lvmetad might not be there.
Hold global lock in pvscan --lvmetad. (This might need refinement.)
Add PV name to "PV gone" messages.
Adjust some log message severities. (More changes needed.)
If the thin pool has disabled zeroing (created with -Zn), we at least
clear initial 4KiB of such thin volume (provisions 1st block).
If lvcreate is executed with '-an' command will abort (same way like we for
normal LV - however for normal LV option -Zn may skip clearing completely,
for thin volumes this option is not supported (applies only for pools).
The OpenAIS checkpoint library is going away; therefore, cmirrord must
operate without it. The algorithms the handle the timing of when to send
a checkpoint, the determination of what to send, and which ongoing cluster
requests are relevent with respect to the checkpoints are unaffected. We
need only replace the functions that actually perform the storing/transmitting
and retrieving/receiving of the checkpoint data. Rather than store the
checkpoint data in an OpenAIS checkpoint file, we simply transmit it along
with the message that notifies the incoming node that the checkpoint is
ready.