IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
If you run multiple runs of unittest.main, unless you don't pass exit=true
the test case always ends with a 0 exit code. Add ability to store the
result of each invocation of the test and exit with a non-zero exit code
if anyone of them fail.
Because of the different code paths we need to test job handling with
all operations. Test now runs virtually everything with timeout == 0
and timeout == 15 so that we test both use cases.
Note: If a client passes -1 for the timeout value they need to make
sure that their connection time out is also infinite. Otherwise, if the client
times out the service side hangs any new dbus calls until the job
that is in progress completes. Not sure why this behavior is occuring
at this time, but it appears a limitation/bug of the dbus-python library.
The methods were returning an instance of the object instead of the
object path which was causing an exception when the result was returned
with the job object as we are explicity trying to return an object path.
Unit test added which re-creates the issue and verifies the fix.
- Prevent --lvmshell with --nojson, not a valid combination
- If user is preventing json, then no lvmshell usage
- Return boolean on Manager.UseLvmShell
When we test Vg.LvCreateRaid some of the hidden LVs volume type go from
'I' to 'i' between the time it takes us to create the LV and
the time it takes to call into refresh to verify the service is up to date.
This is a fairly rare occurance.
This simple tool calls the Manager.Refresh method on the dbus service
to check and see if the dbus service has the most up to date state.
This is to be used for testing to ensure that event driven updates are
working as planned.
Signed-off-by: Tony Asleson <tasleson@redhat.com>
export LVMDBUSD_SESSION=True to run on the session bus instead
of the system bus so that we can run the unit test without
installing the dbus conf file.
Signed-off-by: Tony Asleson <tasleson@redhat.com>
Reduced the size of LVs created and use actual PE numbers instead of hard
coding them to allow us to work with the loop back devices.
Signed-off-by: Tony Asleson <tasleson@redhat.com>