If two devices in an array failed, it was previously impossible to replace
just one of them. This patch allows for the replacement of some, but perhaps
not all, failed devices.
The logic for resuming the original and newly split LVs was not properly
done to handle situations where anything but the last device in the array
was split. It did not take into account the possible name collisions that
might occur when the original LV undergoes the shifting and renaming of its
sub-LVs.
When down-converting a RAID1 device, it is the last device that is extracted
and removed when the user does not specify a particular device. However,
when a device is specified (and it is not the last), the device is removed and
the remaining sub-LVs are "shifted down" to fill the hole. This cause problems
when resuming the LV because if the shifted devices were resumed (and thus
renamed) before the sub-LV being extracted, there would be a name conflict.
The solution is to resume the extracted sub-LVs first so that they can be
properly renamed preventing a possible conflict.
This addresses bug 801967.
The code fail to account for the case where we just need a single device
in a RAID 4/5/6 array. There is no good way to tell the allocation functions
that we don't need parity devices when we are allocating just a single device.
So, I've used a bit of a hack. If we are allocating an area_count that is <=
the parity count, then we can assume we are simply allocating a replacement
device (i.e. no need to include parity devices in the calculations). This
should make sense in most cases. If we need to allocate replacement devices
due to failure (or moving), we will never allocate more than the parity count;
or we would cause the array to become unusable. If we are creating a new device,
we should always create more stripes than parity devices.
Failure to do so results in "Performing unsafe table load while X device(s) are
known to be suspended" errors. While fixing the problem in this way works and
is consistent with the way the mirror segment type does it, it would be nice
to find a solution that uses the generic suspend/resume calls.
Also included in this check-in are additions to the test suite that perform
conversions on RAID LVs under a snapshot. These tests are disabled for the
time being due to a kernel bug that is yet to be tracked down.
Also, don't allow a splitmirror operation on a RAID LV that is already tracking
a split, unless the operation is to stop the tracking and complete the split.
Example:
~> lvconvert --splitmirrors 1 --trackchanges vg/lv /dev/sdc1
# Now tracking changes - image can be merged back or split-off for good
~> lvconvert --splitmirrors 1 -n new_name vg/lv /dev/sdc1
# ^ Completes split ^
If a split is performed on a RAID that is tracking an already split image and
PVs are provided, we must ensure that
1) the already split LV is represented in the PVs
2) we are careful to split only the tracked image
RAID is not like traditional LVM mirroring. LVM mirroring required failed
devices to be removed or the logical volume would simply hang. RAID arrays can
keep on running with failed devices. In fact, for RAID types other than RAID1,
removing a device would mean substituting an error target or converting to a
lower level RAID (e.g. RAID6 -> RAID5, or RAID4/5 to RAID0). Therefore, rather
than removing a failed device unconditionally and potentially allocating a
replacement, RAID allows the user to "replace" a device with a new one. This
approach is a 1-step solution vs the current 2-step solution.
example> lvconvert --replace <dev_to_remove> vg/lv [possible_replacement_PVs]
'--replace' can be specified more than once.
example> lvconvert --replace /dev/sdb1 --replace /dev/sdc1 vg/lv
Example:
~> lvconvert --type raid1 vg/mirror_lv
Steps to convert "mirror" to "raid1"
1) Allocate a RAID metadata LV for each mirror image from the same PVs
on which they are located.
2) Clear the metadata LVs. This involves writing LVM metadata, so we don't
change any aspects of the mirror LV before this so that the user can easily
remove LVs from the failed convert attempt while retaining the original
mirror.
3) Remove the mirror log, if it exists.
4) Add metadata LVs to mirror LV
5) Rename mirror sub-lvs (s/mimage/rimage/)
6) Change flags and segtype from mirror to raid1
Example:
~> lvconvert --type raid1 -m 1 vg/lv
The following steps are performed to convert linear to RAID1:
1) Allocate a metadata device from the same PV as the linear device
to provide the metadata/data LV pair required for all RAID components.
2) Allocate the required number of metadata/data LV pairs for the
remaining additional images.
3) Clear the metadata LVs. This performs a LVM metadata update.
4) Create the top-level RAID LV and add the component devices.
We want to make any failure easy to unwind. This is why we don't create the
top-level LV and add the components until the last step. Should anything
happen before that, the user could simply remove the unnecessary images. Also,
we want to ensure that the metadata LVs are cleared before forming the array to
prevent stale information from polluting the new array.
A new macro 'seg_is_linear' was added to allow us to distinguish linear LVs
from striped LVs.
seg->areas and seg->meta_areas. We also need to copy the memory from the
old arrays to the newly allocated arrays. The amount of memory to copy was
determined by seg->area_count. However, seg->area_count was being set to the
higher value after copying the 'seg->areas' information, but before copying
the 'seg->meta_areas' information. This means we were copying more memory
than necessary for 'seg->meta_areas' - something that could lead to a segfault.
Revert John patch, which fixed only 1 place where ~LVM_WRITE was in use and
convert ommited LVM_READ/WRITE flags to 64bit constants as well.
(Since both 'status' flags for LV and VG are 64bit.)
LVM_WRITE is a 32-bit flag. Now that RAID[_IMAGE|_META] are 64-bit,
and'ing a RAID LV's status against LVM_WRITE can reset the higher order
flags.
A similar thing will affect thinp flags if not careful.
This patch adds the ability to upconvert a raid1 array - say from 2-way to
3-way. It does not yet support upconverting linear to n-way.
The 'raid' device-mapper target allows for individual components (images) of
an array to be specified for rebuild. This mechanism is used when adding
new images to the array so that the new images can be resync'ed while the
rest of the images in the array can remain 'in-sync'. (There is no
mirror-on-mirror layering required.)
~> lvconvert --splitmirrors 1 --trackchanges vg/lv
The '--trackchanges' option allows a user the ability to use an image of
a RAID1 array for the purposes of temporary read-only access. The image
can be merged back into the array at a later time and only the blocks that
have changed in the array since the split will be resync'ed. This
operation can be thought of as a partial split. The image is never completely
extracted from the array, in that the array reserves the position the device
occupied and tracks the differences between the array and the split image via
a bitmap. The image itself is rendered read-only and the name (<LV>_rimage_*)
cannot be changed. The user can complete the split (permanently splitting the
image from the array) by re-issuing the 'lvconvert' command without the
'--trackchanges' argument and specifying the '--name' argument.
~> lvconvert --splitmirrors 1 --name my_split vg/lv
Merging the tracked image back into the array is done with the '--merge'
option (included in a follow-on patch).
~> lvconvert --merge vg/lv_rimage_<n>
The internal mechanics of this are relatively simple. The 'raid' device-
mapper target allows for the specification of an empty slot in an array
via '- -'. This is what will be used if a partial activation of an array
is ever required. (It would also be possible to use 'error' targets in
place of the '- -'.) If a RAID image is found to be both read-only and
visible, then it is considered separate from the array and '- -' is used
to hold it's position in the array. So, all that needs to be done to
temporarily split an image from the array /and/ cause the kernel target's
bitmap to track (aka "mark") changes made is to make the specified image
visible and read-only. To merge the device back into the array, the image
needs to be returned to the read/write state of the top-level LV and made
invisible.
Users already have the ability to split an image from an LV of "mirror"
segtype. This patch extends that ability to LVs of "raid1" segtype.
This patch only allows a single image to be split off, however. (The
"mirror" segtype allows an arbitrary number of images to be split off.
e.g. 4-way => 3-way/linear, 2-way/2-way, linear,3-way)
of top-level LV.
We can't activate sub-lv's that are being removed from a RAID1 LV while it
is suspended. However, this is what was being used to have them show-up
so we could remove them. 'sync_local_dev_names' is a sufficient and
proper replacement and can be done after the top-level LV is resumed.
1) add new function 'raid_remove_top_layer' which will be useful
to other conversion functions later (also cleans up code)
2) Add error messages if raid_[extract|add]_images fails
3) Add function prototypes to prevent compiler warnings when
compiling with '--with-raid=shared'
Fix a couple more issues that kabi found.
- Add some error messages in failure cases
- s/malloc/zalloc/
- use vg->vgmem for lv names instead of vg->cmd->mem