1
0
mirror of git://sourceware.org/git/lvm2.git synced 2024-12-22 17:35:59 +03:00
Commit Graph

21 Commits

Author SHA1 Message Date
Tony Asleson
4cbe789f9c lvmdbusd: Remove unused import 2023-02-27 09:57:18 -06:00
Tony Asleson
5561281f0a lvmdbusd: Fix grammar 2023-02-20 12:01:53 -06:00
Tony Asleson
d88998f516 lvmdbusd: Correct get_object_path_by_uuid_lvm_id
When checking to see if the PV is missing we incorrectly checked that the
path_create was equal to PV creation.  However, there are cases where we
are doing a lookup where the path_create == None.  In this case, we would
fail to set lvm_id == None which caused a problem as we had more than 1
PV that was missing.  When this occurred, the second lookup matched the
first missing PV that was added to the object manager.  This resulted in
the following:

Traceback (most recent call last):
  File "/usr/lib/python3.9/site-packages/lvmdbusd/utils.py", line 667, in _run
    self.rc = self.f(*self.args)
  File "/usr/lib/python3.9/site-packages/lvmdbusd/fetch.py", line 25, in _main_thread_load
    (changes, remove) = load_pvs(
  File "/usr/lib/python3.9/site-packages/lvmdbusd/pv.py", line 46, in load_pvs
    return common(
  File "/usr/lib/python3.9/site-packages/lvmdbusd/loader.py", line 55, in common
    del existing_paths[dbus_object.dbus_object_path()]

Because we expect to find the object in existing_paths if we found it in
the lookup.

resolves: https://bugzilla.redhat.com/show_bug.cgi?id=2085078
2022-09-20 16:36:53 -05:00
Tony Asleson
cb32b0a87f lvmdbusd: Use common function for traceback
We were using a number of different ways to achieve the same result.  Use
a common function to make this consistent.
2022-09-16 10:49:37 -05:00
Tony Asleson
60e4ba36e0 lvmdbusd: Remove unused locking functionality
I don't think we have ever utilized this, remove.
2022-09-16 10:49:37 -05:00
Tony Asleson
068073e924 lvmdbusd: Correct typos 2022-09-16 10:49:36 -05:00
Tony Asleson
b4c3382990 lvmdbusd: Correct object manager lookups
When we have two logical volumes which switch their names at the
same time we are left with incorrect lookups.  Anytime we find
an entry by doing a lookup by UUID or by name we will ensure
that the lookups are indeed correct.

Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1642176
2019-01-16 16:29:05 -06:00
Tony Asleson
405a3689bc lvmdbusd: Correct PV lookups
When a user does a Manager.PvCreate they can specify the block device using a
device path that may be different than what lvm reports is the device path.  For
example a user could use:

/dev/disk/by-id/wwn-0x5002538500000000 instead of /dev/sdc

In this case the pvcreate will succeed, but when we query lvm we don't find the
newly created PV. We fail because it's device path is returned as /dev/sdc.  This
change re-uses an internal lookup which can accommodate this and correctly find
the newly created PV.

Corrects https://bugzilla.redhat.com/show_bug.cgi?id=1445654
2017-05-05 10:30:06 -05:00
Tony Asleson
e53454d6de lvmdbusd: Use work queue for queries too
We need to place query operations in the queue to prevent the case where
a client knows of something before the service does.  For example if a
client creates a PV/VG/LV outside of the dbus API and then immediately
tries to lookup and use that resource in the lvm dbus service it should
be present.  By placing the queries in the work queue any previous
refresh operation will complete before we process the query.
2017-03-09 16:39:47 -06:00
Tony Asleson
bd96036835 lvmdbusd: Use 'pv_missing' column instead of '[unknown]'
Previously using '[unknown]' for PV device path comparison which
is incorrect as it's not always true.
2016-09-28 12:07:48 -05:00
Tony Asleson
be5eb995d3 lvmdbusd: Remove extraneous parameter
Remove 'gen_new' parameter as it's not needed, correct documentation.
2016-09-28 12:05:44 -05:00
Tony Asleson
a93616cf66 lvmdbusd: Add diagnostic validate for look ups
Make sure that the lookup tables don't have extranoues stuff in
them.
2016-09-27 13:28:54 -05:00
Tony Asleson
063265eacd lvmdbusd: Allow PV device names to be '[unknown]'
When a PV device is missing lvm will return '[unknown]' for the device
path.  The object manager keeps a hash table lookup for uuid and for PV's
device name.  When we had multiple PVs with the same device path we
we only had 1 key in the table for the lvm id (device path).  This caused
a problem when the PV device transitioned from '[unknown]' to known as any
subsequent transitions would cause an exception:

Traceback (most recent call last):
  File "/usr/lib/python3.5/site-packages/lvmdbusd/request.py", line 66, in run_cmd
    result = self.method(*self.arguments)
  File "/usr/lib/python3.5/site-packages/lvmdbusd/manager.py", line 205, in _pv_scan
    cfg.load()
  File "/usr/lib/python3.5/site-packages/lvmdbusd/fetch.py", line 24, in load
    cache_refresh=False)[1]
  File "/usr/lib/python3.5/site-packages/lvmdbusd/pv.py", line 48, in load_pvs
    emit_signal, cache_refresh)
  File "/usr/lib/python3.5/site-packages/lvmdbusd/loader.py", line 80, in common
    cfg.om.remove_object(cfg.om.get_object_by_path(k), True)
  File "/usr/lib/python3.5/site-packages/lvmdbusd/objectmanager.py", line 153, in remove_object
    self._lookup_remove(path)
  File "/usr/lib/python3.5/site-packages/lvmdbusd/objectmanager.py", line 97, in _lookup_remove
    del self._id_to_object_path[lvm_id]
KeyError: '[unknown]'

when trying to delete a key that wasn't present.  In this case we don't add a
lookup key for the device path and the PV can only be located by UUID.

Ref: https://bugzilla.redhat.com/show_bug.cgi?id=1379357
2016-09-27 13:28:54 -05:00
Tony Asleson
a882eb2b3b lvmdbusd: Clean up objectmanager.get_object_path_by_uuid_lvm_id
This method grew crufty with a number of stuble bugs.  Refactor and
simplify.
2016-09-27 13:28:54 -05:00
Tony Asleson
5392a612dc lvmdbusd: WS/pep8 corrections 2016-08-29 15:28:06 -05:00
Tony Asleson
9e3ad37828 lvmdbusd: Clean up ws 2016-06-28 12:45:28 -05:00
Tony Asleson
b81186e535 lvmdbusd: Add method get_object_path_by_lvm_id
The object manager method get_object_by_lvm_id was used in many cases for
the sole reason of getting the object path for the object.  Instead of
retrieving the object and then calling 'dbus_object_path' on the object, we
are adding a method which returns the object path.
2016-06-10 16:04:43 -05:00
Tony Asleson
b717e8fe1d lvmdbusd: Rename get_object_path_by_lvm_id
Renaming to get_object_path_by_uuid_lvm_id, to clarify that both the uuid
and the lvm id are required.
2016-06-10 15:28:42 -05:00
Tony Asleson
41ebed7077 lvmdbusd: Change print statement to py3 syntax 2016-06-10 15:28:42 -05:00
Tony Asleson
a0c7875c54 lvmdbusd: Allow PV devices to be referenced by symlink(s)
See: https://bugzilla.redhat.com/show_bug.cgi?id=1318754

Signed-off-by: Tony Asleson <tasleson@redhat.com>
2016-03-21 17:28:51 -05:00
Alasdair G Kergon
5987562cf9 lvmdbus: Add new daemon. 2016-02-17 23:53:35 +00:00