IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
A full search for duplicate PVs in the case of pvs -a
is only necessary when duplicates have previously been
detected in lvmcache. Use a global variable from lvmcache
to indicate that duplicate PVs exist, so we can skip the
search for duplicates when none exist.
Previously, 'pvs -a' displayed the VG name for only the device
associated with the cached PV (pv->dev), and other duplicate
devices would have a blank VG name. This commit displays the
VG name for each of the duplicate devices. The cost of doing
this is not small: for each PV processed, the list of all
devices must be searched for duplicates.
When multiple duplicate devices are specified on the
command line, the PV is processed once for each of them,
but pv->dev is the device used each time.
This overrides the PV device to reflect the duplicate
device that was specified on the command line. This is
done by hacking the lvmcache to replace pv->dev with the
device of the duplicate being processed. (It would be
preferable to override pv->dev without munging the content
of the cache, and without sprinkling special cases throughout
the code.)
This override only applies when multiple duplicate devices are
specified on the command line. When only a single duplicate
device of pv->dev is specified, the priority is to display the
cached pv->dev, so pv->dev is not overridden by the named
duplicate device.
In the examples below, loop3 is the cached device referenced
by pv->dev, and is given priority for processing. Only after
loop3 is processed/displayed, will other duplicate devices
loop0/loop1 appear (when requested on the command line.)
With two duplicate devices, loop0 and loop3:
# pvs
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop0
PV VG Fmt Attr PSize PFree
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m
# pvs /dev/loop3
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop0
PV VG Fmt Attr PSize PFree
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m
# pvs /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop0
PV VG Fmt Attr PSize PFree
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m
# pvs -o+dev_size /dev/loop0 /dev/loop3
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop0
PV VG Fmt Attr PSize PFree DevSize
/dev/loop0 loopa lvm2 a-- 12.00m 12.00m 16.00m
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m 32.00m
With three duplicate devices, loop0, loop1, loop3:
# pvs -o+dev_size
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop1 not /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop1
PV VG Fmt Attr PSize PFree DevSize
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m 32.00m
# pvs -o+dev_size /dev/loop3
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop1 not /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop1
PV VG Fmt Attr PSize PFree DevSize
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m 32.00m
# pvs -o+dev_size /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop1 not /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop1
PV VG Fmt Attr PSize PFree DevSize
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m 32.00m
# pvs -o+dev_size /dev/loop1
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop1 not /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop1
PV VG Fmt Attr PSize PFree DevSize
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m 32.00m
# pvs -o+dev_size /dev/loop3 /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop1 not /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop1
PV VG Fmt Attr PSize PFree DevSize
/dev/loop0 loopa lvm2 a-- 12.00m 12.00m 16.00m
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m 32.00m
# pvs -o+dev_size /dev/loop3 /dev/loop1
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop1 not /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop1
PV VG Fmt Attr PSize PFree DevSize
/dev/loop1 loopa lvm2 a-- 12.00m 12.00m 32.00m
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m 32.00m
# pvs -o+dev_size /dev/loop0 /dev/loop1
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop1 not /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop1
PV VG Fmt Attr PSize PFree DevSize
/dev/loop1 loopa lvm2 a-- 12.00m 12.00m 32.00m
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m 32.00m
# pvs -o+dev_size /dev/loop0 /dev/loop1 /dev/loop3
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop1 not /dev/loop0
Found duplicate PV XhLbpVo0hmuwrMQLjfxuAvPFUFZqD4vr: using /dev/loop3 not /dev/loop1
PV VG Fmt Attr PSize PFree DevSize
/dev/loop0 loopa lvm2 a-- 12.00m 12.00m 16.00m
/dev/loop1 loopa lvm2 a-- 12.00m 12.00m 32.00m
/dev/loop3 loopa lvm2 a-- 12.00m 12.00m 32.00m
Processes a PV once for each time a device with its PV ID
exists on the command line.
This fixes a regression in the case where:
. devices /dev/sdA and /dev/sdB where clones (same PV ID)
. the cached VG references /dev/sdA
. before the regression, the command: pvs /dev/sdB
would display the cached device clone /dev/sdA
. after the regression, pvs /dev/sdB would display nothing,
causing vgimportclone /dev/sdB to fail.
. with this fix, pvs /dev/sdB displays /dev/sdA
Also, pvs /dev/sdA /dev/sdB will report two lines, one for each
device on the command line, but /dev/sdA is displayed for each.
This only works without lvmetad.
When processing PVs specified on the command line, the arg
name was being matched against pv_dev_name, which will not
always work:
- The PV specified on the command line could be an alias,
e.g. /dev/disk/by-id/...
- The PV specified on the command line could be any random
path to the device, e.g. /dev/../dev/sdb
To fix this, first resolve the named PV args to struct device's,
then iterate through the devices for processing.
The call to dm_config_destroy can derefence result->mem
while result is still NULL:
struct dm_config_tree *get_cachepolicy_params(struct cmd_context *cmd)
{
...
int ok = 0;
...
if (!(result = dm_config_flatten(current)))
goto_out;
...
ok = 1;
out:
if (!ok) {
dm_config_destroy(result)
...
}
...
}
ignore_vg now returns 0 for the FAILED_CLUSTERED case,
so all the ignore_vg 1 cases will return vg's with an
empty vg->pvs, so we do not need to iterate through
vg->pvs to remove the entries from the devices list.
Clean up whitespace problems in that area from the
previous commit.
- Fix problems with recent changes related to skipping in:
. _process_vgnameid_list
. _process_pvs_in_vgs
- Undo unnecessary changes to the code structure and readability.
- Preserve valid but minor changes:
. testing FAILED bit values in ignore_vg
. using "skip" value from ignore_vg instead of "ret" value
. applying the sigint check to the start of all loops
. setting stack backtrace when ECMD_PROCESSED is not returned,
i.e. apply the following pattern:
ret = process_foo();
if (ret != ECMD_PROCESSED)
stack;
if (ret > ret_max)
ret_max = ret;
Extend/fix d8923457b8 commit.
'skip'-ed VG is not holding any lock - so don't unlock such VG.
At the same time simplify the code around and relase VG at a single
place and unlock only not skiped and not ignored VGs.
Rework ignore_vg() API so it properly handles
multiple kind of vg_read_error() states.
Skip processing only otherwise valid VG.
Always return ECMD_FAILED when break is detected.
Check sigint_caught() in front of dm iterator loop.
Add stack for _process failing ret codes.
LVM2.2.02.112/tools/toollib.c:1991: leaked_storage: Variable "iter" going out of scope leaks the storage it points to.
LVM2.2.02.112/lib/filters/filter-usable.c:89: leaked_storage: Variable "f" going out of scope leaks the storage it points to.
LVM2.2.02.112/lib/activate/dev_manager.c:1874: leaked_handle: Handle variable "fd" going out of scope leaks the handle.
Let's use this function for more activations in the code.
'needs_exlusive' will enforce exlusive type for any given LV.
We may want to activate LV in exlusive mode, even when we know
the LV (as is) supports non-exlusive activation as well.
lvcreate -ay -> exclusive & local
lvcreate -aay -> exclusive & local
lvcreate -aly -> exclusive & local
lvcreate -aey -> exclusive (might be on any node).
Tool will use internal activation of unused cache pool to
clear metadata area before next use of cache-pool.
So allow to deactivation unused pool in case some error
case happend and we were not able to deactivation pool
right after metadata wipe.
Because of the recent change to process_each_pv(), the vg is always
provided when the pv is in a vg. is_pv(pv) means the pv is in a vg,
which means that the vg arg will not be NULL, which means the removed
block of code is not needed.
When we are given an existing LV name - it needs to be allowed
to pass in even restricted name as the LV could have existed
long before we introduced some new restriction on prefix/suffix.i
Fix the regression on name limits and drop restriction to be applied
on any existing LVs - only the new created LV names have to be
complient with current name restrictions.
FIXME: we are currently using restricted names incorrectly in few
other places - device_is_usable() skips restricted names,
and udev flags are also incorrectly set for restricted names
so these LVs are not getting links properly.
The warnings arg was used to enable logging of warnings
when reading a PV. This arg is turned into a set of flags
with the WARN_PV_READ flag matching the existing behavior.
A new flag WARN_INCONSISTENT is added that will cause
vg_read_internal() to log the "VG is not consistent"
warning so the various callers do not need to log
this warning themselves.
A new vg_read flag READ_WARN_INCONSISTENT is used from
reporting to enable the WARN_INCONSISTENT flag in
vg_read_internal.
[Committed by agk with cosmetic changes and tweaks.]
Process PVs by iterating through VGs, then iterating through
devices if the command needs to process non-PV devices.
The process_single function can always use the VG and PV args.
[Committed by agk with cosmetic changes and tweaks.]
Copy the same form as the new process_each_vg.
Replace unused struct cmd_vg and cmd_vg_read() replicator
code with struct vg and vg_read() directly.
The failed_lvnames arg is no longer used since the
cmd_vg replicator wrapper was removed.
[Committed by agk with cosmetic changes and tweaks.]
Split VG argument collection from processing.
This allows the two different loops through VGs to
be replaced by a single loop.
Replace unused struct cmd_vg and cmd_vg_read() replicator
code with struct vg and vg_read() directly.
[Committed by agk with cosmetic changes and tweaks.]
There are actually three filter chains if lvmetad is used:
- cmd->lvmetad_filter used when when scanning devices for lvmetad
- cmd->filter used when processing lvmetad responses
- cmd->full_fiilter (which is just cmd->lvmetad_filter + cmd->filter chained together) used
for remaining situations
This patch adds the third one - "cmd->full_filter" - currently this is
used if device processing does not fall into any of the groups before,
for example, devices which does not have the PV label yet and we're just
creating a new one or we're processing the devices where the list of the
devices (PVs) is not returned by lvmetad initially.
Currently, the cmd->full_filter is used exactly in these functions:
- lvmcache_label_scan
- _pvcreate_check
- pvcreate_vol
- lvmdiskscan
- pvscan
- _process_each_label
If lvmetad is used, then simply cmd->full_filter == cmd->filter because
cmd->lvmetad_filter is NULL in this case.
Split internals of extract_vgname into _extract_vgname.
This common code will be used for other similar function.
Reuse skip_dev_dir() instead of less mature coded to skip
device dir.
Instead of duplicating full vg/lv name - allocate string
only vg portion of lv name.
Use lv_is_* macros throughout the code base, introducing
lv_is_pvmove, lv_is_locked, lv_is_converting and lv_is_merging.
lv_is_mirror_type no longer includes pvmove.
When ignoring 'listed' volume, print info message.
(So the final command error message is a bit less confusing,
i.e. when user tries to deactive virtual origin:
> lvchange -an vg/lvol2_vorigin
Ignoring virtual origin logical volume vg/lvol2_vorigin.
One or more specified logical volume(s) not found.
Fix get_pool_params to only read params.
Add poolmetadataspare option to get_pool_params.
Move all profile code into update_pool_params.
Move recalculate code into pool_manip.c