In the context of dm, 'device' refers to a dm device, but
in the context of lvm, 'device' refers to struct device.
Change some lvm function names to make that difference clearer.
dev_manager_get_device_list() -> dev_manager_get_dm_active_devices()
get_device_list() -> get_dm_active_devices()
device_get_uuid() -> dev_dm_uuid(), devno_dm_uuid()
Over the time the code for preloading detached LVs got unnecessarily
complicate. But actually we need to preload only LVs that
were previously non-toplevel (invisible) LVs and became visible
toplevel LVs in the precommitted metadata.
If there would be needed some other rule, it would likely be a bug in
conversion code forgetting to set visibility flag on detached LV.
This reduces number of unnecessary repeated DM tree preloading.
External origins for thin volumes can be also used at the same time
as old(thick) snapshot origins. However in this case it's possible
the LV is only active as being 'external' origin, but old snapshot LVs
are not active. For this case before handling these
LVs for un/monitoring check the active state of origin LV.
This should prevent warnings of monitoring failures.
Instead of parsing the whole /proc/kallsyms use faster variant
of using modprobe tool logic.
lvm2 here wants to know whether the particular DM cache policy is
present in the kernel - however since the cache policy does not have
any kernel module parameters and it can be built-in to a kernel
there is no /sys/modules directory in such case and we would need to call
modprobe everytime we want detect such case.
The old solution tried to look for particular kernel symbol
(and like not the right way, as smq_exit might be actually ommitted).
New version checks MODULES_PATH/`uname -r`/modules.builtin for
whether is present cache policy module instead of CPU expensive parsing
of kallsyms.
Replace the use of internal /dev/mapper names with the use of
public LV names /dev/vg/lv for use with repair tools.
For this make the activation of _pmspare LV to be handled as
a component activation with public name.
Metadata is already atomatically activated this way (as readonly).
So if there is any 'error' happening, we leave public LVs in
system.
Introduce struct vdo_pool_size_config usable to calculate necessary
memory size for active VDO volume.
Function lv_vdo_pool_size_config() is able to read out this
configuration out of runtime DM table line.
Names matching internal code layout.
Functionc in thin_manip.c uses thin_pool in its name.
Keep 'pool' only for function working for both cache and thin pools.
No change of functionality.
When the volume size is extended, there is no need to flush
IO operations (nothing can be targeting new space yet).
VDO target is supported as target that can safely work with
this condition.
Such support is also needed, when extending VDOPOOL size
while the pool is reaching its capacity - since this allows
to continue working without reaching 'out-of-space' condition
due to flushing of all in flight IO.
Since we check for present DM devices - cache result for
futher use of checking presence of such device.
lvm2 uses cache result for label scan, but also when
it tries to activate or deactivate LV - however only simple
target 'striped' is reasonably supported.
Use disable_dm_devs to be able to control when lv_info()
get cache or uncached results.
TODO: support more type, however this is getting very complicated.
When check active componet of thinLV with external origin,
we need to check if the external origin isn't already active.
For this however we need to use layered check for -real device.
Just like with other segtype use this function to get whole
raid status info available per a single ioctl call.
Also it nicely simplifies read of percentage info about
in_sync portion of raid volume.
TODO: drop use of other calls then lv_raid_status call,
since all such calls could already use status - so it just
adds unnecessary duplication.
Reduce ioctl count and avoid separate info check,
when we can get the same info from status ioctl.
When devmanager calls return 0, then the exists value 0
means the reason of failure is missing device in table.
In such case we avoid stack trace.
Swap the flush parameter for the vdo status function
to match thin pool status.
When LV is deactivativate, we check for presence, and later
for some LV types also for being in use.
We can however do this check in 1 step for them a remove extra ioctl.
Add return value '2' to lv_check_not_in_use() to recognize LV is not
present.
Existing users were just testing for 0, so no change for them.
Make the generic "device is not usable" message from filter-usable
more specific in case the device is not usable because it's an LV.
(i.e. when scan_lvs=0)
Introduce structures lv_status_thin_pool and
lv_status_thin (pair to lv_status_cache, lv_status_vdo)
Convert lv_thin_percent() -> lv_thin_status()
and lv_thin_pool_percent() + lv_thin_pool_transaction_id() ->
lv_thin_pool_status().
This way a function user can see not only percentages, but also
other important status info about thin-pool.
TODO:
This patch tries to not change too many other things,
but pool_below_threshold() now uses new thin-pool info to return
failure if thin-pool cannot be actually modified.
This should be handle separately in a better way.
When thetable reload fails during suspend() - we were only calling
plain resume() - and this will reload only those devices,
which were left suspend, but will not try to restore
metadata state according to lvm2 reverted metadata.
So if we were reloading device tree - we have restored
only top-level LV and rest of reverted device manipulation
were left alone and possibly mismatched what is in committed
metadata.
FIXME: There are several cases were such revert will likely not work
properly anyway as some operation are currenly handled in single commit,
while they need multiple commits, but it's step towards better correctness.
At least we catch there errors now earlier.
This is probably somewhat experimantal patch - but when i.e. raid device
is just extend, there should not be a technical need for flush,
unless the target would stricly need it. It should allow faster
processing of lvm command not being blocked by possibly longer flush.
dm-integrity stores checksums of the data written to an
LV, and returns an error if data read from the LV does
not match the previously saved checksum. When used on
raid images, dm-raid will correct the error by reading
the block from another image, and the device user sees
no error. The integrity metadata (checksums) are stored
on an internal LV allocated by lvm for each linear image.
The internal LV is allocated on the same PV as the image.
Create a raid LV with an integrity layer over each
raid image (for raid levels 1,4,5,6,10):
lvcreate --type raidN --raidintegrity y [options]
Add an integrity layer to images of an existing raid LV:
lvconvert --raidintegrity y LV
Remove the integrity layer from images of a raid LV:
lvconvert --raidintegrity n LV
Settings
Use --raidintegritymode journal|bitmap (journal is default)
to configure the method used by dm-integrity to ensure
crash consistency.
Initialization
When integrity is added to an LV, the kernel needs to
initialize the integrity metadata/checksums for all blocks
in the LV. The data corruption checking performed by
dm-integrity will only operate on areas of the LV that
are already initialized. The progress of integrity
initialization is reported by the "syncpercent" LV
reporting field (and under the Cpy%Sync lvs column.)
Example: create a raid1 LV with integrity:
$ lvcreate --type raid1 -m1 --raidintegrity y -n rr -L1G foo
Creating integrity metadata LV rr_rimage_0_imeta with size 12.00 MiB.
Logical volume "rr_rimage_0_imeta" created.
Creating integrity metadata LV rr_rimage_1_imeta with size 12.00 MiB.
Logical volume "rr_rimage_1_imeta" created.
Logical volume "rr" created.
$ lvs -a foo
LV VG Attr LSize Origin Cpy%Sync
rr foo rwi-a-r--- 1.00g 4.93
[rr_rimage_0] foo gwi-aor--- 1.00g [rr_rimage_0_iorig] 41.02
[rr_rimage_0_imeta] foo ewi-ao---- 12.00m
[rr_rimage_0_iorig] foo -wi-ao---- 1.00g
[rr_rimage_1] foo gwi-aor--- 1.00g [rr_rimage_1_iorig] 39.45
[rr_rimage_1_imeta] foo ewi-ao---- 12.00m
[rr_rimage_1_iorig] foo -wi-ao---- 1.00g
[rr_rmeta_0] foo ewi-aor--- 4.00m
[rr_rmeta_1] foo ewi-aor--- 4.00m
Enhance lv_info with lv_info_with_name_check.
This 'variant' not only check existance if UUID in DM table
but also compares its DM name whether it's matching expected LV name.
Otherwise activation may 'skip' activation with rename in case the
DM UUID already exists, just device is different name.
This change make fairly easier manipulation with i.e. detached mirror
leg which ATM is using same UUID - just the LV name have been changed.
Used code was not able to run 'activation' (and do a rename) and just
skipped the call. So the code used to do a workaround and 'tried'
to deactivate such LV firts - this however work only in non-clvmd case,
as cluster was not having the lock for deactivated LV.
With this extended lv_info code will run 'activation' and will
synchronize the name to match expected LV name.
Patch extends _lv_info() with new paramter 'with_name_check',
which is later translated into 'name_check' argument for
_info_run() which in case of name mismatch evaluates the
check as if device does not exists.
Such call is only used in one place _lv_activate() which then
let activation run. All other invocation of _info() calls
are left intact.
TODO: fix mirror table manipulation (and raid)....