This test can't use brd (ramdisk) as backend since for some
weird reason lsblk is not listing these device.
TODO: test could be probably rewritten to avoid using lsblk somehow??
When the backend device supports only 4K blocks (like ramdisk)
we cannot use for testing any smaller blocksize.
So recalc test for 4K extent size.
We may possibly introduce one list extra test that
can be executed on devices with 512b sectors to
check lvm2 support those min extent sizes...
In case "lvconvert -mN RaidLV" was used on a degraded
raid1 LV, success was returned instead of an error.
Provide message to inform about the need to repair first
before changing number of mirrors and exit with error.
Add new lvconvert-m-raid1-degraded.sh test.
Resolves: rhbz1573960
There are likely more bits of code that can be removed,
e.g. lvm1/pool-specific bits of code that were identified
using FMT flags.
The vgconvert command can likely be reduced further.
The lvm1-specific config settings should probably have
some other fields set for proper deprecation.
Instead of using delayer device user 'zero' device and let mirror
do some real work which takes some time.
In case the test machine is too fast - mirror might need to be made bigger
to meet needed criteria.
Also move all test needed this 'zero' PV trick to the end of test
so $dev2 and $dev4 are covered with 'zero' and can take any amount of
write without consuming any real space.
For reporting commands (pvs,vgs,lvs,pvdisplay,vgdisplay,lvdisplay)
we do not need to repeat the label scan of devices in vg_read if
they all had matching metadata in the initial label scan. The
data read by label scan can just be reused for the vg_read.
This cuts the amount of device i/o in half, from two reads of
each device to one. We have to be careful to avoid repairing
the VG if we've skipped rescanning. (The VG repair code is very
poor, and will be redone soon.)
Test that no (Sub)LV remnants persist if the volume group is
not listed in configuration variable activation/volume_list,
hence not activatable thus causing initialization of rmeta
SubLVs to fail.
Related: rhbz1161347
Correct testing with format 1 and mq policy.
Add testing of 'smq'
Fix testing with clvmd - where logged message is part of clvmd log
and we can only check command status.
Use 4K chunks since some older kernels are not capable
to create striped volumes with smaller size.
TODO: lvm2 should detect this ahead and avoid kernel
reporting "Invalid chunk".
Add three new raid tests with io load and table
reloads during reshape for target 1.13.2.
Add a raid0 to raid10 conversion test.
Also add more signals to trap in lvconvert-raid-reshape-load.sh.
Avoiding "$(get first_extent_sector "$d")" in the loop
allows the test to succeed in the cluster. Further cluster
analysis needed to get to the core reason.
The lvm2 test suite aims at small test resource footprints
(few PVs, small PV sizes) to run on tmpfs backed loop device.
OTOH, lvconvert-reshape-raid.sh aims to test the maxima of
supported total stripes of 64. This patch adds a prerequisite
conditional to skip tests using more than 14 stripes.
It requires the target version 1.13.1 to avoid deadlocks.
In some cases the message could be slightly misleading so use
here rather conditional.
TODO:
In future we may possibly further tune the message in case we are
certain the level of redundancy protection has not been reduced.