Respect lvm2_log_fn prototype. The idea of 'reusing' print_log with
plain cast is causing very strange crashes with some older 'gcc' compilers.
So just do it cleanly...
Failures in the temporary mirror used when up-converting cause dmeventd
to issue 'lvconvert --repair' on the sub-LV, <lv_name>_mimagetmp_?. The
'lvconvert' command refuses to deal with this sub-LV outright - it
expects to be given the name of the top-level LV. So, just like we do
with mirrored logs, we strip-off the portion of the name that is not
the top-level LV and issue the command on the top-level LV instead.
Start separating the validation from the action in the basic lvresize
code moved to the library.
Remove incorrect use of command line error codes from lvresize library
functions. Move errors.h to tools directory to reinforce this,
exporting public versions of the error codes in lvm2cmd.h for dmeventd
plugins to use.
Switch to use libdm dm_get_status_snapshot() function for
reading status info.
This fixes bug, where the code was using 32bit integers,
while the snapshot target is able to return 64bit sizes.
However this also means, someone is using >1TB snapshot
cow devices, which is actually very bad idea anyway, since the
perfomance and memory usage in this case is very bad.
Reset counter after thin pool resize failure.
If the pool goes above threshold, support unmounting
of all thin volumes if the lvextend fails to avoid
overfilling of the pool.
various dmeventd plug-ins into a new function called 'dmeventd_lvm2_command',
but the new function did not strip off the "_mlog" extentions that the
mirror plug-in had been doing. This created bug 794904 - failure to replace
devices in a redundant log.
The test suite did catch this scenario because it performs repair tests (mainly)
through the CLI and not dmeventd. It's also not easy to test because the test
itself will hang if the bug is encountered.
As atoi may return negative value - test for both limits.
Test log_args for limits before calling alloca().
Code from dmeventd mirror plugin should probably share same code as
we have in mirrored.c.
For snapshot, prepare whole command in front into private buffer.
Add also some missing '\n' for syslog messages.
For raid and mirror only convert creation of command line string.