#!/usr/bin/env bash # Copyright (C) 2018-2021 Red Hat, Inc. All rights reserved. # # This copyrighted material is made available to anyone wishing to use, # modify, copy, or redistribute it subject to the terms and conditions # of the GNU General Public License v.2. # # You should have received a copy of the GNU General Public License # along with this program; if not, write to the Free Software Foundation, # Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA SKIP_WITH_LVMPOLLD=1 SKIP_WITH_LVMLOCKD=1 . lib/inittest RUNDIR="/run" test -d "$RUNDIR" || RUNDIR="/var/run" PVS_ONLINE_DIR="$RUNDIR/lvm/pvs_online" VGS_ONLINE_DIR="$RUNDIR/lvm/vgs_online" HINTS="$RUNDIR/lvm/hints" DFDIR="$LVM_SYSTEM_DIR/devices" DF="$DFDIR/system.devices" _clear_online_files() { # wait till udev is finished aux udev_wait rm -f "$PVS_ONLINE_DIR"/* "$VGS_ONLINE_DIR"/* } # This stops lvm from taking advantage of hints which # will have already excluded md components. # This stops lvm from asking udev if a dev is an md component. # LVM will ask udev if a dev is an md component, but we don't # want to rely on that ability in this test. aux lvmconf "devices/md_component_detection = 1" \ "devices/hints = \"none\"" \ "devices/obtain_device_list_from_udev = 0" \ "devices/search_for_devnames = \"none\"" aux extend_filter_md "a|/dev/md|" aux prepare_devs 3 for level in 1 0 ; do # create 2 disk MD raid1 array # by default using metadata format 1.0 with data at the end of device # # When a raid0 md array is stopped, the components will not look like # duplicate PVs as they do with raid1. # mdadm does not seem to like --chunk=64 with raid1 case "$level" in 0) CHUNK="--chunk=64" ;; *) CHUNK="" ;; esac aux mdadm_create --metadata=1.0 --level=$level $CHUNK --raid-devices=2 "$dev1" "$dev2" mddev=$(< MD_DEV) vgcreate $vg "$mddev" lvmdevices || true pvs -o+deviceidtype,deviceid PVIDMD=$(get pv_field "$mddev" uuid | tr -d - ) lvcreate -n $lv1 -l 2 $vg lvcreate -n $lv2 -l 2 -an $vg lvchange -ay $vg/$lv2 check lv_field $vg/$lv1 lv_active "active" # lvm does not show md components as PVs pvs "$mddev" not pvs "$dev1" not pvs "$dev2" pvs | tee out not grep "$dev1" out not grep "$dev2" out vgchange -an $vg # When the md device is started, lvm will see that and know to # scan for md components, so stop the md device to remove this # advantage so we will test the fallback detection. mdadm --stop "$mddev" aux udev_wait # The md components should still be detected and excluded. not pvs "$dev1" not pvs "$dev2" pvs | tee out not grep "$dev1" out not grep "$dev2" out pvs 2>&1|tee out not grep "Not using device" out # should not activate from the md legs not vgchange -ay $vg # should not show an active lv not dmsetup info $vg-$lv1 # should not allow updating vg not lvcreate -l1 $vg # should not activate from the md legs _clear_online_files pvscan --cache -aay "$dev1" pvscan --cache -aay "$dev2" test ! -f "$RUNDIR/lvm/pvs_online/$PVIDMD" test ! -f "$RUNDIR/lvm/vgs_online/$vg" # should not show an active lv not dmsetup info $vg-$lv1 aux mdadm_assemble "$mddev" "$dev1" "$dev2" not pvs "$dev1" not pvs "$dev2" pvs | tee out not grep "$dev1" out not grep "$dev2" out lvs $vg vgchange -an $vg # should not activate from the md legs _clear_online_files pvscan --cache -aay "$dev1" pvscan --cache -aay "$dev2" test ! -f "$RUNDIR/lvm/pvs_online/$PVIDMD" test ! -f "$RUNDIR/lvm/vgs_online/$vg" # should not show an active lv not dmsetup info $vg-$lv1 vgchange -ay $vg check lv_field $vg/$lv1 lv_active "active" vgchange -an $vg _clear_online_files pvscan --cache -aay "$mddev" test -f "$RUNDIR/lvm/pvs_online/$PVIDMD" test -f "$RUNDIR/lvm/vgs_online/$vg" check active $vg $lv1 vgchange -an $vg vgremove -f $vg aux cleanup_md_dev aux wipefs_a "$dev1" aux wipefs_a "$dev2" aux udev_wait done # Repeat tests using the default config settings aux lvmconf "devices/hints = \"all\"" \ "devices/obtain_device_list_from_udev = 1" \ "devices/search_for_devnames = \"none\"" rm $DF || true # create 2 disk MD raid0 array # by default using metadata format 1.0 with data at the end of device # When a raid0 md array is stopped, the components will not look like # duplicate PVs as they do with raid1. aux mdadm_create --metadata=1.0 --level=0 --chunk=64 --raid-devices=2 "$dev1" "$dev2" mddev=$(< MD_DEV) # Create an unused PV so that there is at least one PV in the hints # when the MD dev is stopped. If there are no PVs, the hints are # empty, and the code falls back to scanning all, and we do not end # up testing the code with hints actively used. pvcreate "$dev3" vgcreate $vg "$mddev" PVIDMD=$(get pv_field "$mddev" uuid | tr -d - ) lvcreate -n $lv1 -l 2 $vg lvcreate -n $lv2 -l 2 -an $vg lvchange -ay $vg/$lv2 check lv_field $vg/$lv1 lv_active "active" # lvm does not show md components as PVs pvs "$mddev" not pvs "$dev1" not pvs "$dev2" pvs > out not grep "$dev1" out not grep "$dev2" out grep "$mddev" "$HINTS" grep "$dev3" "$HINTS" not grep "$dev1" "$HINTS" not grep "$dev2" "$HINTS" vgchange -an $vg # When the md device is started, lvm will see that and know to # scan for md components, so stop the md device to remove this # advantage so we will test the fallback detection. mdadm --stop "$mddev" aux udev_wait # A WARNING indicating duplicate PVs is printed by 'pvs' in this # case. It's printed during the scan, but after the scan, the # md component detection is run on the devs and they are dropped # when we see they are md components. So, we ignore the warning # containing the word duplicate, and look for the "Not using device" # message, which shouldn't appear, as it would indicate that # we didn't drop the md components. # FIXME: we should avoid printing the premature warning indicating # duplicate PVs which are eventually recognized as md components # and dropped. pvs 2>&1|tee out1 grep -v -e WARNING -e "Devices file PVID" out1 > out2 not grep "Not using device" out2 not grep "$mddev" out2 not grep "$dev1" out2 not grep "$dev2" out2 grep "$dev3" out2 cat "$HINTS" pvs 2>&1|tee out1 grep -v -e WARNING -e "Devices file PVID" out1 > out2 not grep "Not using device" out2 not grep "$mddev" out2 not grep "$dev1" out2 not grep "$dev2" out2 grep "$dev3" out2 cat "$HINTS" # The md components should still be detected and excluded. not pvs "$dev1" not pvs "$dev2" pvs | tee out not grep "$dev1" out not grep "$dev2" out grep "$dev3" out # should not activate from the md legs not vgchange -ay $vg # should not show an active lv not dmsetup info $vg-$lv1 # should not allow updating vg not lvcreate -l1 $vg # should not activate from the md legs _clear_online_files pvscan --cache -aay "$dev1" pvscan --cache -aay "$dev2" test ! -f "$RUNDIR/lvm/pvs_online/$PVIDMD" test ! -f "$RUNDIR/lvm/vgs_online/$vg" # should not show an active lv not dmsetup info $vg-$lv1 # start the md dev aux mdadm_assemble "$mddev" "$dev1" "$dev2" not pvs "$dev1" not pvs "$dev2" pvs | tee out not grep "$dev1" out not grep "$dev2" out lvs $vg vgchange -an $vg # should not activate from the md legs _clear_online_files pvscan --cache -aay "$dev1" pvscan --cache -aay "$dev2" test ! -f "$RUNDIR/lvm/pvs_online/$PVIDMD" test ! -f "$RUNDIR/lvm/vgs_online/$vg" # should not show an active lv not dmsetup info $vg-$lv1 vgchange -ay $vg check lv_field $vg/$lv1 lv_active "active" vgchange -an $vg _clear_online_files pvscan --cache -aay "$mddev" test -f "$RUNDIR/lvm/pvs_online/$PVIDMD" test -f "$RUNDIR/lvm/vgs_online/$vg" check active $vg $lv1 vgchange -an $vg vgremove -f $vg aux cleanup_md_dev